VNS_CRAV: Auricular Vagal Stimulation in Alcohol Craving

Sponsor
Medical University of Vienna (Other)
Overall Status
Completed
CT.gov ID
NCT05131334
Collaborator
(none)
30
1
1
4
7.4

Study Details

Study Description

Brief Summary

Background: The cause of the vegetative symptoms is a sympathetic driven misbalance of the autonomous nervous system. To restore vegetative balance in alcohol withdrawal syndrome new neuro-modulatory methods, such as percutaneous auricular vagal stimulation (pVNS) could be used. Measuring the pupil size is a suitable method to assess imbalances or dysfunctions of the vegetative regulation in individuals. Objective: The objective of this study is to assess the pupil reaction to the cholinergic antagonist tropicamide in alcohol withdrawal syndrome as a biomarker of the vegetative balance before and after pVNS. Methods: 30 patients aged between 20 and 65 were recruited in this open-label, controlled pilot trial with repeated measure design. pVNS was administered at the left cymba conchae for 72 hours with intermitted stimulation. Pupillometric recording lasted about 60 min and was performed at baseline and following pVNS. The reaction of the pupil to an anticholinergic agent was measured as a receptor-test in terms of a psychophysiological feedback mechanism to pVNS.

Condition or Disease Intervention/Treatment Phase
  • Device: auriStim, for auricular vagal stimulation
N/A

Detailed Description

The chronic consumption of alcohol leads to a pathophysiological adaptation of the nervous system, by an increase in glutamatergic receptors and a decrease in GABAergic receptor functions. Autonomic and psychomotor hyperactive disorders, such as nausea, tremor, diaphoresis, hypersensitive reflexes, hypertension, and tachycardia, as well as negative emotional states, characterized by restlessness, anxiety, dysphoria, and irritability occur 6 to 24 hours after cessation of alcohol consumption. The cause of the vegetative symptoms is a sympathetic driven misbalance of the autonomous nervous system. The negative state of health can last for a very long time and is the main reason for relapses.

Pharmacological treatment of alcohol withdrawal syndrome consists of ether Benzodiazepines or GHB is an endogenous metabolite of γ-aminobutyric acid (GABA).

The rate of successful treatment is lowest for alcohol dependence among all psychiatric disorders. Therefore, it seems important to carry out further interdisciplinary investigations in the direction of new and effective treatment methods. To restore vegetative balance in alcohol-withdrawal syndrome novel neuromodulatory approaches, such percutaneous auricular vagal stimulation (pVNS) could be beneficial.

The pupil size changes, like other physiological markers, e.g., hyperventilation, blood pressure and heart rate, serves as psychophysiological marker of the autonomic nervous system (ANS). Beside the fact that pupil size is determined by balance between the parasympathetic ANS (PANS) and the sympathetic ANS (SANS), measuring the static and dynamic pupillary diameters are suitable parameters measuring imbalances or dysfunction of the vegetative regulation. The pupil diameter oscillates spontaneously at low frequencies, which is an almost constant oscillatory change in the pupil size. Like pupil size, it is generally assumed that pupil oscillation is regulated by a dynamic interaction between parasympathetic (cholinergic) and sympathetic (noradrenergic) activity.

In this study, the investigator assessed the pupil reaction to the cholinergic antagonist tropicamide in alcohol withdrawal syndrome as a biomarker of the vegetative balance before and after pVNS. The Investigator hypothesized that pVNS will enhance the parasympathomimetic tone represented by a reduction of pupillary diameter in a parasympatholytic pharmacological challenge with tropicamide after vagal stimulation.

Study Design

The pilot study applied an open-label, unblinded, repeated measures design with three time points of pupillometry measurements at two testing days. For baseline measurements, the static pupil measurement was taken with the head fixed in a position and with open eyes (0'). Followed by an administration one drop of 0.01% tropicamide-solution into the left eye. The dynamic pupil measure followed 20 minutes (20') and 40 minutes (40') after tropicamide application. In our protocol the investigator scheduled a 60' measurement, which was removed due to the finding, that a maximum dilation was measured after 40' and that patients became increasingly agitated and weary, often leading to biased recordings at baseline measurement. Absolute change (mm), and relative change (%) of the pupil diameter was calculated.

Next, auriStim (AU0115, Multisana GmbH, Vienna, Austria) was placed for percutaneous vagal stimulation (pVNS). Patients were stimulated for 72 hours, with an intermittent stimulation mode, switching from active to resting state all three hours. After the stimulation period, patients placed their head in a fixed position for the second pupil measurement. For dynamic measurements, tropicamide was induced and measures were taken after 20' and 40'. Again, the investigator calculated absolute and relative changes of the pupil diameter. For each recording the investigator analyzed pupillary oscillations with a Fourier analysis as biomarker of the central nervous activation. All patients were tested at the same time of the day (between 9:00 and 10:00 a.m.) to exclude diurnal variation in pupillary diameter at day two and day five of the inpatient alcohol withdrawal.

Percutaneous auricular vagal nerve stimulation (pVNS)

For auricular vagal stimulation the investigator used auriStim (AU0115, Multisana GmbH, Vienna, Austria). Using a green light-emitting diode (LEDs) flashlight, blood vessels in the cymba conchae of the left ear side were detected. Minimal invasive needles (penetrating 1-2mm) were placed close to the vessel-bifurcation to provide efficient stimulation of the auricular branch of the vagus nerve. The built-in microchip controls monophasic volt pulses of 1 ms, with alternating polarity, a frequency of 1 Hz and an amplitude of 4V. Stimulation lasted for 72h in total with alternating on/off periods of three hours. Thereafter, the device was removed, and patients continued their therapy consisting of anti-withdrawal medication.

Quantitative pupillometry

Before recording, patients were acquainted to the test environment (160 lux) in a noise-protected room (3 x 4 meters) for three minutes. With head held steady in a chin- and forehead rest, the patients positioned their left eye in front of the camera and fixed a black dot, at 1.6m distance, to prevent accommodation. Pupillometry was performed using a non-invasive, personal computer-based infrared digital video pupillometer system (TV pupillometer 1050, Whittaker Corporation., California, Los Angeles). Incorporated five milliwatts, infra-red LEDs provide continuous illumination of the eye, with a wavelength of 850nm to achieve high contrast filming condition, and to which the pupil does not respond. The system integrates a calibrated light stimulation of fixed intensity (145 lux) and duration (300ms) to induce a light-evoked pupillary reaction. The system allows a precise (0.01mm limit) and rapid (50Hz) measure of the vertical diameter, and automatically determines static pupil size (averaged over the first 25.6sec of recording) and a series of dynamic pupillary parameters after light stimulation. Dynamic parameters include resting pupil diameter (pupil diameter just before light-stimulation), the latency for constriction (the latency time from the light flash exposure to the start of pupillary constriction), the amplitude of constriction (the value of the resting diameter minus the maximum constriction diameter), the constrictive ratio (amplitude of constriction/resting pupil diameter), the duration of constriction (time interval between the start of constriction, and the time point of maximum constriction) and peak constriction velocity. The recording of the pupillary diameter and response curve is shown as a graph of the pupillary diameter against time. Based on the measurement of static pupillary diameter (first 25.6sec) the pupillometer calculates pupillary oscillations by Fourier analysis (FA), reflecting the activation of the central nervous system. Prior to Fourier Analysis a linear interpolation was applied to artefacts such as blinking and missing data by a built-in noise removal program. For FA the investigator used five individual frequency bands: 0.0 - 0.2, 0.21 - 0.4, 0.41 - 0-6, 0.61 - 0.8, 0.81 - 1 Hz and whole power spectrum 0.0 - 1 Hz.

Study Design

Study Type:
Interventional
Actual Enrollment :
30 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Auricular Vagus Nerve Stimulation (auriStim) Against Alcohol-craving Measured by Pupillary Reaction - Pilotstudy
Actual Study Start Date :
Oct 1, 2018
Actual Primary Completion Date :
Jan 31, 2019
Actual Study Completion Date :
Feb 1, 2019

Arms and Interventions

Arm Intervention/Treatment
Other: intervention group

The pilot study applied an open-label, unblinded, repeated measures design with three time points of pupillometry measurements at two testing days. Patient serving as their own controls

Device: auriStim, for auricular vagal stimulation
For auricular vagal stimulation we used auriStim (AU0115, Multisana GmbH, Vienna, Austria). Using a green light-emitting diode (LEDs) flashlight, blood vessels in the cymba conchae of the left ear side were detected. Minimal invasive needles (penetrating 1-2mm) were placed close to the vessel-bifurcation to provide efficient stimulation of the auricular branch of the vagus nerve. The built-in microchip controls monophasic volt pulses of 1 ms, with alternating polarity, a frequency of 1 Hz and an amplitude of 4V. Stimulation lasted for 72h in total with alternating on/off periods of three hours. Thereafter, the device was removed, and patients continued their therapy consisting of anti-withdrawal medication.

Outcome Measures

Primary Outcome Measures

  1. mean pupillary diameter [3 days]

    change of the mean pupillary diameter in millimeter (mm), provoked by the parasympatholytic agent tropicamide (1 drop of 0.01% tropicamide solution administered into the left eye)

Secondary Outcome Measures

  1. resting pupillary diameter (millimeter) [3 days]

    pupil diameter just before light-stimulation

  2. latency (milliseconds) [3 days]

    the latency time from the light flash exposure to the start of pupillary constriction

  3. amplitude of constriction (millimeter) [3 days]

    the value of the resting diameter minus the maximum constriction diameter

  4. constrictive ratio (percent) [3 days]

    amplitude of constriction/resting pupil diameter

  5. duration of constriction (milliseconds) [3 days]

    time interval between the start of constriction, and the time point of maximum constriction

  6. Pupillary oscillations (Hz) [3 days]

    Calculation of the pupillary oscillations by Fourier analysis.

Eligibility Criteria

Criteria

Ages Eligible for Study:
20 Years to 65 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • diagnosis of alcohol dependence according to ICD-10 and DSM-V

  • aged between 20 and 65

  • Ability to perform oral and written informed consent to the study protocol

Exclusion Criteria:
  • age under 20 or over 65 years

  • taking medication affecting the pupillary measurements (opioids, acetylcholinesterase inhibitors, sympathomimetics)

  • positive pregnancy test

  • diagnosed anxiety disorders

  • multiple substance abuse disorder

  • ocular disease

  • delirious patients

  • biochemical implants

  • hemophilia

  • psoriasis vulgaris

Contacts and Locations

Locations

Site City State Country Postal Code
1 Medical University of Vienna, Department of Psychiatry and Psychotherapy Vienna Austria 1090

Sponsors and Collaborators

  • Medical University of Vienna

Investigators

  • Principal Investigator: Henriette Walter, Prof., Department of Psychiatry and Psychotherapy, Medical University of Vienna

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Michael Treiber, Principal Investigator, Medical University of Vienna
ClinicalTrials.gov Identifier:
NCT05131334
Other Study ID Numbers:
  • 2284/2017
First Posted:
Nov 23, 2021
Last Update Posted:
Nov 23, 2021
Last Verified:
Nov 1, 2021
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Michael Treiber, Principal Investigator, Medical University of Vienna

Study Results

No Results Posted as of Nov 23, 2021