Evaluation of the BD OneFlow Acute Leukemia Panel on the BD FACSLyric Flow Cytometer

Sponsor
Becton, Dickinson and Company (Industry)
Overall Status
Recruiting
CT.gov ID
NCT05035615
Collaborator
(none)
200
7
17.9
28.6
1.6

Study Details

Study Description

Brief Summary

This study is a multi-site, prospective performance study to determine equivalency between the investigational OneFlow Acute Leukemia Panel on the FACSLyric system versus the final clinical diagnosis.

Condition or Disease Intervention/Treatment Phase
  • Other: IUO Acute Leukemia Panel

Detailed Description

Hematology laboratories rely on flow cytometry technology (in addition to classic hematological methods) to aid in screening, diagnosing, and monitoring patients with hematological disorders. High speed and broad applicability of flow cytometry allows for the diagnosis. Currently, there are no consensus panels being used; consequently, the leukemia & lymphoma (L&L) testing remains a single-vial antibody being used, with various in-house laboratory developed tests (LDTs) being used to test patient specimens. Furthermore, the analysis of flow cytometer generated data is not standardized and requires a high level of expertise and training for interpretation of complex data. Therefore, optimized and standardized immunostaining protocols for the diagnosis, classification, and prognostic sub-classification of hematological malignancies are needed.

Enrollment will occur at up to 8 investigational sites . Data will be acquired from Eligible remnant/leftover specimens on the BD FACSLyric flow cytometer and evaluated by site personnel and expert analysts .

The final diagnosis and the affected cell population will be determined by site standard of care .

Analysis of data will evaluate identification of 1) normal vs abnormal cell populations and 2) BCP-ALL, AML, and less certain diseases by the expert & site analysts as compared to the final diagnosis.

Study Design

Study Type:
Observational
Anticipated Enrollment :
200 participants
Observational Model:
Cohort
Time Perspective:
Cross-Sectional
Official Title:
Evaluation of the BD OneFlow Acute Leukemia Panel (BD OneFlow ALOT, BCP-ALL T1, and AML T1-T4) on the BD FACSLyric Flow Cytometer Using Leftover, De-identified Specimens
Actual Study Start Date :
Nov 2, 2021
Anticipated Primary Completion Date :
Apr 30, 2023
Anticipated Study Completion Date :
Apr 30, 2023

Arms and Interventions

Arm Intervention/Treatment
Remnant/ Leftover specimens

Specimens that meet inclusion/exclusions criteria, are leftover from routine flow cytometry testing, and are from subjects having or suspected of having a hematological or non-hematological disorder.

Other: IUO Acute Leukemia Panel
This Investigational Panel , comprised of 6 reagents , is intended for in vitro diagnostic use for qualitative flow-cytometric immunophenotyping of immature hematopoietic cell populations. These reagents are used as an aid in the differential diagnosis of hematologically abnormal patients having, or suspected of having, B-cell acute lymphoblastic leukemia or acute myeloid leukemia.

Outcome Measures

Primary Outcome Measures

  1. Comparison between expert analysts' determination of normal and abnormal specimen and final diagnosis (Sensitivity Analysis) [Within 24 Hours of specimen collection]

    Determine equivalence between the investigational OneFlow Acute Leukemia Panel on the BD FACSLyric system results analyzed by two independent experts versus the final clinical diagnosis for Normal (lymphoid and myeloid) or Abnormal (neoplastic lymphoid or myeloid) phenotypes. Sensitivity will be calculated

  2. Comparison between expert analysts' determination of normal and abnormal specimen and final diagnosis (Specificity Analysis) [Within 24 Hours of specimen collection]

    Determine equivalence between the investigational OneFlow Acute Leukemia Panel on the BD FACSLyric system results analyzed by two independent experts versus the final clinical diagnosis for Normal (lymphoid and myeloid) or Abnormal (neoplastic lymphoid or myeloid) phenotypes. Specificity will be calculated

Eligibility Criteria

Criteria

Ages Eligible for Study:
3 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. Specimen collected/handled prior to enrollment in accordance with site policies and procedures.

  2. Specimen with adequate volume (1 mL) to complete protocol tests.

  3. Specimen is leftover PB and BM from routine flow cytometry laboratory testing for having or suspected of having acute leukemia disorders (i.e. AML, BCP-ALL, ALAL, etc.), myelodysplastic syndrome (MDS), other hematological, or non-hematological disorders.

  4. Specimen from newly diagnosed or relapsed subject.

  5. Only one specimen type (PB or BM) shall be enrolled per given subject.

  6. Specimen is stored at room temperature, upon receipt by the site.

  7. Specimens are collected in EDTA (K2 or K3) or heparin (sodium or lithium).

  8. Age of specimen (BCP ALL T1: time of collection to start of first pre-wash; ALOT, AML T1-T4: time of collection to start of staining): ≤ 24 hours.

  9. Specimens are from subjects irrespective of race, gender, and ethnicity

Exclusion Criteria:
  1. Specimen is from healthy subject.

  2. Specimen from subject <3 years of age.

  3. Specimen is from subject undergoing any treatment for any form of leukemia.

  4. Specimen is from subject with minimal residual disease (MRD) as determined by the site.

  5. Specimen is from subject suspected of plasma cell disorders.

  6. Visibly clotted specimen.

  7. Visibly hemolyzed specimen.

  8. Frozen specimen.

  9. Refrigerated specimen.

  10. Fixed specimen.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Childrens Hospital Los Angeles Los Angeles California United States 90027
2 University Of North Carolina Chapel Hill North Carolina United States 27514
3 CorePath Laboratories San Antonio Texas United States 78229
4 Fleury Group San Paolo Brazil 01323--020
5 Motol University Hospital, Childhood Leukemia Investigation Prague Czechia
6 University of Salamanca Salamanca Spain 37007
7 Cambridge University Cambridge United Kingdom CB2 0QQ

Sponsors and Collaborators

  • Becton, Dickinson and Company

Investigators

  • Study Director: Imelda Omana-Zapata, MD, PHD, Becton, Dickinson and Company

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Becton, Dickinson and Company
ClinicalTrials.gov Identifier:
NCT05035615
Other Study ID Numbers:
  • CAS-OFLYRICALL-IVDR
First Posted:
Sep 5, 2021
Last Update Posted:
Jul 18, 2022
Last Verified:
Jul 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results