Axial Length Variability

Sponsor
Vienna Institute for Research in Ocular Surgery (Other)
Overall Status
Completed
CT.gov ID
NCT04580550
Collaborator
(none)
50
1
1
4
12.6

Study Details

Study Description

Brief Summary

The accuracy of IOL calculation relies on the one hand on axial length measurements and on the other hand on corneal and lens thickness measurements.

AL difference in pre and postoperative measurements may be caused by changes of lens parameters.

Aim of this study is to evaluate the magnitude of changes in pre and postoperative measurements of AL.

Condition or Disease Intervention/Treatment Phase
  • Other: Axial length variability
N/A

Detailed Description

This is a prospective observational, controlled and unmasked study that would include patients which undergo cataract presurgical examination, after patient signed written informed consent. For each patient only one eye will be included.

In total 50 eyes of 50 patients will be include. Due to missing previous data, the sample size is an approximation.

Prior to surgery, slit lamp examination and cataract grading (LOCS) is performed. Routine biometry is performed using the IOL Master 700 (Carl Zeiss Meditec AG, Jena, Germany) and Heidelberg Anterion (Heidelberg Engineering, Germany) for AL and lens measurement.

Additionally, evaluation of tilt and decentration will be performed using Purkinje meter device.

Follow-up examination will be performed three months after surgery and will contain: AL and lens measurement using the two ss-OCT biometery devices, lens evaluation (tilt and decentration of the IOL) using the Purkinje meter. Refractive outcome will be evaluated by determining best-corrected visual acuity and subjective refraction.

In women of childbearing age, a pregnancy test will be performed before inclusion into the study.

Main outcome variable:

• Extend of AL difference between pre- and postoperative measurements in both devices

Additional outcome variables:
  • Agreement between the two ss-OCT devices in AL measurement

  • Evaluation of lens parameter in AL differences between pre- and postoperative measurements

  • Limit of agreement in lens tilt and decentration using two ss-OCT devices and Purkinje meter

Study Design

Study Type:
Interventional
Actual Enrollment :
50 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Other
Official Title:
Evaluation of Axial Length Changes Between Pre and Postoperative Measurements
Actual Study Start Date :
Nov 1, 2019
Actual Primary Completion Date :
Mar 1, 2020
Actual Study Completion Date :
Mar 1, 2020

Arms and Interventions

Arm Intervention/Treatment
Other: Axial length variability

Aim of this study is to evaluate the magnitude of changes in pre and postoperative measurements of AL.

Other: Axial length variability
Biometry (axial length measurement)is performed using the IOL Master 700 (Carl Zeiss Meditec AG, Jena, Germany) and Heidelberg Anterion (Heidelberg Engineering, Germany) pre and postoperatively.

Outcome Measures

Primary Outcome Measures

  1. Axial length variability [3 months]

    Evaluation of changes in axial length pre and post cataract surgery using two ss-OCT biometers

Secondary Outcome Measures

  1. Lens tilt and decentration [3 months]

    Evaluation of lens tilt and decantation using the Purkinje meter and two ss-OCT devices

Eligibility Criteria

Criteria

Ages Eligible for Study:
21 Years to 100 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Uneventful cataract surgery

  • Age 21 and older

  • Axial length 24.00 mm and bigger

  • CT Asphina 409 M lens implanted

Exclusion Criteria:
  • Intra- or postoperative complication

  • Relevant other ophthalmic diseases that are likely to influence the measurement outcome (as: with severe corneal pathology, severe macular degeneration, severe diabetic retinopathy, dens cataract, PEX syndrome, previous ocular surgery or trauma)

  • Pregnancy

Contacts and Locations

Locations

Site City State Country Postal Code
1 Hanusch Hospital, Ophthalmology department Vienna Austria 1140

Sponsors and Collaborators

  • Vienna Institute for Research in Ocular Surgery

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Prim. Prof. Dr. Oliver Findl, MBA, Head of Department of Ophthalmology, Professor, Principal Investigator, MBA, Vienna Institute for Research in Ocular Surgery
ClinicalTrials.gov Identifier:
NCT04580550
Other Study ID Numbers:
  • Axial length variability
First Posted:
Oct 8, 2020
Last Update Posted:
Oct 8, 2020
Last Verified:
Oct 1, 2020
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Oct 8, 2020