PINNACLE I Clinical Study: A Clinical Trial to Assess the Elixir Medical LithiX Coronary Hertzian Contact Lithotripsy Catheter for Treatment of Moderately to Severely Calcified, Stenotic de Novo Coronary Artery Lesions

Sponsor
Elixir Medical Corporation (Industry)
Overall Status
Not yet recruiting
CT.gov ID
NCT05828173
Collaborator
(none)
60
1
12

Study Details

Study Description

Brief Summary

The objective of the PINNACLE I Clinical Study is to assess safety and performance of the LithiX Coronary Hertzian Contact Lithotripsy Catheter (LithiX Coronary HCLC; LithiX) to treat moderately to severely calcified coronary artery lesions by percutaneous transluminal coronary angioplasty (PTCA).

Condition or Disease Intervention/Treatment Phase
  • Device: LithiX Coronary Hertzian Contact Lithotripsy Catheter (LithiX Coronary HCLC; LithiX)
N/A

Detailed Description

This study is a prospective, multicenter, single-arm clinical study. Enrollment of up to 60 patients requiring percutaneous coronary intervention (PCI) on up to two de novo coronary artery lesions with reference vessel diameters ≥ 2.25 mm and ≤ 3.5 mm, and lesion lengths of ≤ 34 mm, with moderate to severe calcification.

The LithiX Coronary HCLC is a proprietary Hertzian contact lithotripsy catheter delivered through the coronary arterial system to visualize and treat calcified stenoses potentially resistant to full stent expansion. The LithiX Coronary HCLC consists of a semi-compliant balloon featuring multiple rows of stainless-steel hemispheres which are intended to atraumatically disrupt calcium via Hertzian Contact Lithotripsy.

In the Optical Coherence Tomography (OCT) imaging subgroup, approximately 30 patients will undergo OCT imaging at pre-procedure, post-LithiX Coronary HCLC treatment, and the end of procedure following stent deployment.

Subjects will be followed through hospital discharge and will have clinical follow-up conducted by phone at 30 days and 6 months post-index procedure.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
60 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
PINNACLE I Clinical Study: A Clinical Trial to Assess the Elixir Medical LithiX Coronary Hertzian Contact Lithotripsy Catheter for Treatment of Moderately to Severely Calcified, Stenotic de Novo Coronary Artery Lesions
Anticipated Study Start Date :
May 1, 2023
Anticipated Primary Completion Date :
Nov 1, 2023
Anticipated Study Completion Date :
May 1, 2024

Arms and Interventions

Arm Intervention/Treatment
Experimental: LithiX Coronary Hertzian Contact Lithotripsy Treatment

Device: LithiX Coronary Hertzian Contact Lithotripsy Catheter (LithiX Coronary HCLC; LithiX)
Vessel preparation of moderately to severely calcified coronary artery lesions prior to stenting allows for full stent expansion and apposition to the vessel wall

Outcome Measures

Primary Outcome Measures

  1. Major adverse cardiovascular events (MACE) [30 days]

    This is the primary safety endpoint and defined as a per-subject composite endpoint of cardiovascular death, myocardial infarction, and target vessel revascularization.

  2. Clinical success [At the end of procedure]

    This is the primary performance endpoint and defined as residual stenosis <50% after final treatment (with or without stenting) with no evidence of in-hospital MACE.

Secondary Outcome Measures

  1. Angiographic success [During the procedure]

    defined as success in facilitating stent delivery with <50% residual stenosis and without serious angiographic complications

  2. Optical Coherence Tomography (OCT) imaging [During the procedure]

    assessment of the lesion and stent in a subset of patients

  3. All myocardial infarction [Through study completion, an average of 6 months]

    Q-wave and non-Q-wave

  4. Target vessel revascularization [Through study completion, an average of 6 months]

    defined as any repeat percutaneous intervention or surgical bypass of any segment of the target vessel including the target lesion.

  5. Target lesion revascularization [Through study completion, an average of 6 months]

    defined as any repeat percutaneous intervention of the target lesion or bypass surgery of the target vessel performed for restenosis or other complication of the target lesion

  6. Target lesion failure [Through study completion, an average of 6 months]

    defined as a per-subject composite endpoint of cardiovascular death, target vessel myocardial infarction, and clinically-indicated target lesion revascularization

  7. Stent thrombosis [Through study completion, an average of 6 months]

    definite and probable stent thrombosis

  8. All-cause death [Through study completion, an average of 6 months]

    Cardiovascular and non-cardiovascular death

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
General Inclusion Criteria:
  1. Subject is ≥ 18 years of age.

  2. Subject or a legally authorized representative must provide written informed consent prior to any study related procedures.

  3. Subject must agree not to participate in any other clinical study during the course of the study that would interfere with the endpoints of this study.

  4. Subjects must have a single or double vessel coronary artery disease (CAD) and clinical evidence of ischemic heart disease, such as CAD, silent ischemia, stable / unstable angina, and NSTEMI if biomarkers are stable or falling at time of inclusion.

Angiographic Inclusion Criteria:
  1. Subject must have de novo lesion(s) in native coronary arteries suitable for percutaneous coronary intervention.

  2. Up to 2 de novo coronary artery lesions in separate epicardial vessels, which are moderately to severely calcified, meeting all of the following criteria visually assessed by angiography:

  • ≥70% diameter stenosis by visual estimation

  • reference vessel diameters of 2.25 mm - 3.5 mm

  • lesion length of ≤ 34 mm

  • TIMI flow ≥ 1 at baseline

  1. Any non-target lesion must be located in different coronary artery from a target lesion. Treatment of non-target lesion, if any, must be completed prior to treatment of target lesion and must be deemed a clinical angiographic success as visually assessed by the physician.
General Exclusion Criteria:
  1. Subject with a known hypersensitivity or contraindication to aspirin, heparin, bivalirudin, anti-platelet medications, or sensitivity to contrast media which cannot be adequately pre-medicated.

  2. Subject with known diagnosis of STEMI at index presentation or within 7 days of study screening.

  3. Patient refusing or not a candidate for emergency coronary artery bypass grafting (CABG) surgery.

  4. Subject with known pregnancy or is nursing. Women of child-bearing potential should have a documented negative pregnancy test within 7 days before index procedure.

  5. Planned use of atherectomy, laser, lithoplasty, thrombectomy, scoring or cutting balloon, or any investigational device other than LithiX in the target lesion during the index procedure.

  6. Patients on renal dialysis or with known eGFR < 30 ml/min.

  7. NYHA class III or IV heart failure.

  8. Patient has active systemic infection.

  9. Cerebrovascular accident (CVA) or transient ischemic attach (TIA) within the past 6 months.

  10. Active peptic ulcer or active gastrointestinal (GI) bleeding within the past 6 months.

  11. Subject has a known left ventricular ejection fraction (LVEF) <30% (LVEF may be obtained at the time of the index procedure if the value is unknown, if necessary).

  12. Subject is a member of a vulnerable population as defined GCP E6, including individuals with mental disability, persons in nursing homes, children, impoverished persons, persons in emergency situations, homeless persons, nomads, refugees, and those incapable of giving informed consent. Vulnerable populations also may include members of a group with a hierarchical structure such as university students, subordinate hospital and laboratory personnel, employees of the Sponsor, members of the armed forces, and persons kept in detention.

Angiographic Exclusion Criteria:
  1. More than two target lesions or more than 1 target and 1 non-target lesion requiring treatment.

  2. Extreme angulation (90º or greater) proximal to or within the target lesion.

  3. Previous percutaneous intervention of lesions in a target vessel (including side branches) conducted within 6 months before the study procedure, or any prior lesion treated within 10 mm (proximal or distal) from the current target lesion.

  4. Previous percutaneous intervention of lesions in a non-target vessel (including side branches) conducted within 30 days before the study procedure.

  5. Angiographic evidence of a target lesion dissection prior to LithiX Hertzian Contact Lithotripsy.

  6. Visible thrombus (by angiography) at target lesion site.

  7. Unprotected left main coronary artery disease (Greater than 50% diameter stenosis).

  8. Target lesion is located in a native vessel distal to anastomosis with a saphenous vein graft or LIMA/RIMA bypass.

  9. Evidence of aneurysm in target vessel.

  10. Coronary artery spasm of the target vessel in the absence of a significant stenosis.

  11. Target lesion involves a bifurcation requiring treatment with more than one stent or pre-dilatation of a side branch >2.0 mm in diameter

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • Elixir Medical Corporation

Investigators

  • Principal Investigator: Stefan Verheye, MD, PhD, AZ Middelheim, Antwerp, Belgium
  • Principal Investigator: Johan Bennett, MD, PhD, Universitaire Ziekenhuizen Leuven, Leuven, Belgium

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Elixir Medical Corporation
ClinicalTrials.gov Identifier:
NCT05828173
Other Study ID Numbers:
  • ELX-CL-2202
First Posted:
Apr 25, 2023
Last Update Posted:
Apr 25, 2023
Last Verified:
Apr 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Elixir Medical Corporation
Additional relevant MeSH terms:

Study Results

No Results Posted as of Apr 25, 2023