Diagnostic Performance of Coronary CT Angiography With CT FFR in Kidney Transplantation Candidates

Sponsor
Stanford University (Other)
Overall Status
Terminated
CT.gov ID
NCT03248674
Collaborator
Siemens Medical Solutions (Industry)
26
1
28.9
0.9

Study Details

Study Description

Brief Summary

Patients with chronic kidney disease (CKD) before kidney transplantation require that obstructive coronary artery disease (CAD) is excluded, as cardiovascular complications are the leading cause of mortality in kidney transplant patients. However, in this patient population, the optimal method for the detection of obstructive CAD has not been identified. Noninvasive stress tests such as Dobutamine stress echocardiography or nuclear perfusion study have low diagnostic accuracy. CT fractional flow reserve measurement (CT FFR) is a novel non-invasive (FDA approved) imaging test to identify obstructive CAD. The goal of this project is to evaluate the diagnostic accuracy of CT FFR in the detection of obstructive coronary artery disease in patients with chronic kidney disease before kidney transplantation.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: CT FFR

Detailed Description

Transplantation is the therapy of choice for most patients with stage 5 chronic kidney disease (CKD) and end stage renal disease (ESRD). Kidney transplantation improves quality of life and overall survival rates. Cardiovascular disease is the most common complication and leading cause of death in the transplant population. In order to assess the risk of cardiac events perioperatively and after kidney transplantation, the majority of kidney transplantation candidates undergo cardiac evaluation, including non-invasive cardiac stress imaging or invasive coronary angiography before transplantation. Invasive coronary angiography is associated with small but definite risk of bleeding or myocardial infarction, making non-invasive cardiac stress imaging such as dobutamine stress echocardiography (DSE) or nuclear myocardial perfusion scintigraphy (MPS) the preferred method. However, non-invasive cardiac stress imaging in patients with stage 5 CKD and ESRD demonstrates only moderate accuracy. DSE and MPS showed only sensitivities ranging from 0.44 to 0.89 and from 0.29 to 0.92, respectively, for identifying one or more severe coronary artery stenosis (defined as coronary diameter stenosis of more than 70%). Due to the moderate accuracy, several transplant centers (including Stanford) still continue to rely on invasive coronary angiography for their populations instead of non-invasive cardiac testing. Thus improved non-invasive cardiac testing with higher sensitivities and specificity are highly desirable in this patient population.

A promising alternative is the use of coronary CT angiography (cCTA) in combination with CT based fractional flow reserve (CT-FFR). Non-invasive cCTA alone has recently been evaluated in kidney transplantation candidates. It demonstrated high sensitivity (0.93) but limited specificity (0.63) in the detection of obstructive coronary artery disease, most likely related to the high prevalence of coronary artery calcifications in patients with CKD and ESRD. The specificity of coronary CTA can be improved by a new image analysis techniques, which allow the calculation of the hemodynamic significance - expressed as the relative pressure drop across a lesion similar - based on computational fluid dynamics derived from the conventional coronary CTA (6). In various study populations, the combination of coronary CT angiography and CT FFR showed excellent correlation with invasive FFR derived from invasive coronary angiography, which is the current gold standard. The implementation of CT- FFR has shown an improvement of the specificity of coronary CTA , even in the presence of coronary artery calcifications. However, no study so far assessed the diagnostic accuracy of coronary angiography with CT-FFR in candidates for kidney transplantation.

Goal The objective of this project is to evaluate and establish a new non-invasive cardiac test in the detection of coronary artery disease for candidates before kidney transplantation.

Specific Aims We want to confirm the promising results of CT FFR in this specific patient population and want to establish an alternative non-invasive cardiac test.

Study Design This study is designed as a prospective observational cohort study with a study population of 50 -100 patients. All patients who are included in this study will undergo coronary CT angiography with CT-FFR (research part) and a clinically indicated invasive coronary angiography with invasive FFR (standard of care). Coronary angiography and invasive FFR will act as the reference standard.

Study Design

Study Type:
Observational
Actual Enrollment :
26 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Diagnostic Performance of Coronary Computed Tomography Angiography With Computed Tomography Fractional Flow Reserve in Kidney Transplantation Candidates
Actual Study Start Date :
Aug 28, 2017
Actual Primary Completion Date :
Jan 24, 2020
Actual Study Completion Date :
Jan 24, 2020

Outcome Measures

Primary Outcome Measures

  1. Diagnostic accuracy of CT FFR. [CT FFR and Invasive FFR are calculated immediately after coronary CT angiography and invasive coronary angiography]

    Diagnostic accuracy of CT FFR (per vessel) in the detection of hemodynamically significant CAD as compared to invasive FFR derived from invasive coronary angiography (reference standard). Presence or absence of hemodynamically significant coronary artery disease in concordance between CT FFR and invasive FFR. Hemodynamically significant stenosis is defined as CT FFR value below 0.8.

Eligibility Criteria

Criteria

Ages Eligible for Study:
21 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Candidates for kidney transplantation on dialysis without any residual kidney function AND referred to invasive coronary angiography for cardiac evaluation

  • Referral to invasive coronary angiography is based on algorithm used at the Transplant

Readiness Assessment Clinic (TRAC) at Stanford:
    1. Diabetic Candidates older than 45 years.
    1. Diabetic Candidates under 45 years old and any one of the following criteria is present:
    1. 25 year History of Diabetes
    1. 5 year Smoking History
    1. Abnormal EKG (ST-T wave changes)
Exclusion Criteria:
  • Hemodynamically and clinically unstable condition (angina at rest, malignant arrhythmias)

  • Known ischemic heart disease (prior, documented myocardial infarction, prior stenting or coronary artery bypass graft surgery)

  • BMI>30 kg/m2, or weight >120 kg.

  • Atrial fibrillation or other arrhythmia, >6 ectopic beats per minute

  • Known or suspected allergy to iodinated contrast medium

  • Pregnancy cannot be excluded

Contacts and Locations

Locations

Site City State Country Postal Code
1 Stanford Healthcare Stanford California United States 94305

Sponsors and Collaborators

  • Stanford University
  • Siemens Medical Solutions

Investigators

  • Principal Investigator: Dominik Fleischmann, M.D., Stanford Radiology

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Dominik Fleischmann, MD, Professor of Radiology, Stanford University
ClinicalTrials.gov Identifier:
NCT03248674
Other Study ID Numbers:
  • IRB-41455
First Posted:
Aug 14, 2017
Last Update Posted:
Jan 6, 2022
Last Verified:
Dec 1, 2021
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jan 6, 2022