Normothermic Machine Perfusion (NMP) Versus Hypothermic Machine Perfusion (HMP) in Human Kidney Transplantation

Sponsor
Zhang Tianyu (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT05743751
Collaborator
(none)
60
1
2
30.1
2

Study Details

Study Description

Brief Summary

Due to the rising incidence of renal failure and the improvement of organ transplantation technology, the shortage of donor organs has become one of the main problems limiting the development of kidney transplantation. Marginal donor is one of the important ways to extend the donor pool. Normothermic mechanical perfusion (NMP) is a new generation of organ preservation technology, which can maintain the blood supply and at the same time evaluate the marginal kidney function during the organ preservation. However, the clinical effect has not been proved. Hypothermic Machine Perfusion (HMP) is the mainstream organ perfusion technology. This study aims to compare the effectiveness of NMP with the HMP.

Condition or Disease Intervention/Treatment Phase
  • Device: Normothermic machine perfusion
  • Device: Hypothermic machine perfusion
N/A

Detailed Description

The main purpose of the study is to improve the utilization rate of marginal donors through normothermic perfusion, and reduce the incidence of infection, severe rejection and even graft failure caused by implantation of marginal donors. This study aims at the following aspects:

  1. To compare the effects of two methods and perfusion parameters on the quality of marginal donors: normal temperature pulse perfusion and low temperature mechanical perfusion;

  2. Explore the methods of evaluating the function of donor organs;

  3. Exploring the effects of different mechanical perfusion methods and perfusion conditions on marginal donors;

  4. The effect of broad-spectrum antibiotics on improving donor infection through different administration routes and different drug doses during perfusion and preservation.

A single-center prospective randomized controlled study was used to compare the prognosis of renal transplantation between 50 patients with normothermic pulse perfusion and 50 patients with hypothermic mechanical perfusion who were enrolled in our hospital for allograft kidney transplantation.

Assessment factors:
  1. Donor parameters: age, sex, creatinine, diabetes, cause of death, length of stay in ICU, calcification of donor renal artery (CRP expression level)

  2. Perfusion pressure, perfusion time, perfusion temperature, perfusion vessel resistance index

  3. Receptor factors: age, gender, height, weight, BMI, cause of kidney disease (hypertension, diabetes glomerulonephritis, polycystic kidney disease), dialysis time (month), dialysis type (blood/peritoneum), HLA mismatch number, smoking, diabetes, hypertension, heart disease, hyperlipidemia, anemia, complication index (CCI), ASA score (>3 or ≤ 3), operation time, number of donor renal artery branches, number of donor renal vein branches, donor creatinine, cold ischemia time (mins), and the perfusion of the transplanted kidney ( judged by the fluorescence intensity after indocyanine green injection). Laboratory results: PRA (panel-reactive antibody), blood creatinine, estimated glomerular filtration rate (eGFR), blood lactate level, postoperative urine volume. Graft loss, culture result of irrigation solution (bacteria). Sample acquisition: obtaining the blood and urine samples of the recipient and measuring the expression level of globulin A in the serum. In the process of kidney transplantation, the donor's renal artery vessel wall and the recipient's external iliac artery vessel wall were obtained. The blood vessel wall was stained with calcification, CRP to evaluate the calcification of the donor and recipient vessels.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
60 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Masking:
Double (Participant, Care Provider)
Masking Description:
Participant and care provider were blinded to the interventions.
Primary Purpose:
Treatment
Official Title:
Prospective Randomized Controlled Study Normothermic Pulse Perfusion Comparing and Hypothermic Machine Perfusion in Margin Deceased Donor Kidney Transplantation
Anticipated Study Start Date :
Mar 3, 2023
Anticipated Primary Completion Date :
Dec 3, 2024
Anticipated Study Completion Date :
Sep 3, 2025

Arms and Interventions

Arm Intervention/Treatment
Active Comparator: Hypothermic machine perfusion

After organ acquisition, the donor kidney was trimmed, and then the donor kidney was connected to the cryoperfusion machine (lifeport, which has been used in routine clinical practice in our hospital) for continuous low temperature mechanical perfusion (<8 ℃). The perfusion solution was extracted for proteomic study at 10 min after perfusion and at the end of perfusion.

Device: Hypothermic machine perfusion
LifePort Kidney Transporter is designed to integrate with the clinical environment by using readily available supplies, requiring minimal user intervention, and by being easy to use. LifePort Kidney Transporter is a portable, isolated kidney perfusion and transport system, designed to support a donated kidney and to maintain the organ in a near-normal physiologic state under hypothermic aseptic conditions. An insulated plastic housing encloses the kidney and perfusate within a LifePort Kidney Transporter Disposable Perfusion Circuit. LifePort Kidney Transporter components include an Ice Container, Pump Deck, Control Panel, Outer Display, Bubble Detectors, External Connections Panel, sensors, and four lithium-ion batteries. Two handles make the unit easy to lift and carry

Experimental: Normothermic machine perfusion

After conventional UW perfusion is obtained, the marginal donor kidney is immediately perfused without ischemia at normal temperature. The perfusion time is at least 4 hours (so as to repair the marginal donor kidney). The perfusion solution is as above, and the perfusion solution is loaded into the device authorized in Europe (XVIVO - KidneyAssist ®), Connect the transplanted renal artery with the device. Take 5ml perfusion solution in advance before perfusion, 5ml perfusion solution every 30min after perfusion, take perfusion solution at the end of perfusion (blood gas analysis for each perfusion solution, and finally perfusion solution for culture), and measure urine volume every hour. After perfusion, the transplanted kidney was disconnected from the perfusion device, and the donor kidney was perfused again with 2L HTK solution, followed by routine transplantation.

Device: Normothermic machine perfusion
XVIVO (perfusion company, Gothenburg, Sweden), functions to be included in perfusion equipment, cardiopulmonary bypass machine and neonatal cardiopulmonary bypass machine, including polyethylene pipeline, heating equipment (perfusion temperature 37 ℃), venous pool (venous pressure is 0 mmHg, adjust the height of perfusion pool), centrifugal pump (arterial pressure is set at initial 75 mmHg, maintain 65 mmHg). The perfusion solution contains 215ml of dextran/albumin solution and 400ml of hematocrit, 2ml of 10% calcium gluconate, 1300u/L heparin and 400mg of cefazolin sodium. The oxygen/carbon dioxide ratio is (95%/5%, 2L/min) for continuous perfusion, and pO2 is maintained at 650mmHg during perfusion. During perfusion, continue to use verapamil, amino acid, glucose and insulin. Lactic acid Ringer solution (10ml/h) was used to supplement the lost circulation volume due to urine production during perfusion.

Outcome Measures

Primary Outcome Measures

  1. Rate of delayed renal function (DGF) [1 week after surgery]

    At least one dialysis is required within one week after kidney transplantation

Secondary Outcome Measures

  1. Estimated glomerular filtration rate [3, 6, 12 months after surgery]

    Calculated from serum creatinine levels to assess kidney function.

  2. Rate of primary non-function (PNF) [1 months after surgery]

    Dialysis is required because the transplanted kidney is nonfunctional

  3. Graft survival and recipient survival [1 year follow-up]

    Incidence of the Graft survival and recipient survival

  4. Complications [within 90 days after operation]

    incidence of complications

  5. Patient death [1 year follow-up]

    Death date after surgery and the reasons

Other Outcome Measures

  1. Hospitalization expenses [3, 6, 12 months after surgery]

    Total expenses of kidney transplantation

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Age 18-60 years old, gender unlimited

  • Volunteer to participate in this clinical trial and sign the informed consent form

  • Suffering from end-stage renal disease

  • Planned kidney transplantation

  • The expanded standard donors (ECD) were obtained

  • The expanded standard kidney donor is defined as: aged cadaver donors over 60 years old or two or three of the following conditions between 50 and 60 years old: death due to cerebrovascular disease; Hypertension; The blood creatinine level before donation was greater than 133umol/L.

Exclusion Criteria:
  • Active infection

  • Living donor kidney recipient

  • Acute rejection

  • Second kidney transplantation

  • Combined transplantation (combined liver and kidney, combined pancreas and kidney)

  • Patients who take other clinical trial drugs or participate in other clinical studies

  • Unable to continue the research

  • Patients who are judged by the researcher to be unsuitable for this clinical trial

Contacts and Locations

Locations

Site City State Country Postal Code
1 China-Japan Friendship Hospital Beijing Beijing China

Sponsors and Collaborators

  • Zhang Tianyu

Investigators

  • Study Chair: Zhou Xiaofeng, MD, China-Japan Friendship Hospital

Study Documents (Full-Text)

None provided.

More Information

Publications

Responsible Party:
Zhang Tianyu, Principal Investigator, China-Japan Friendship Hospital
ClinicalTrials.gov Identifier:
NCT05743751
Other Study ID Numbers:
  • 2022-NHLHCRF-LX-03
First Posted:
Feb 24, 2023
Last Update Posted:
Feb 24, 2023
Last Verified:
Feb 1, 2023
Individual Participant Data (IPD) Sharing Statement:
Yes
Plan to Share IPD:
Yes
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Keywords provided by Zhang Tianyu, Principal Investigator, China-Japan Friendship Hospital
Additional relevant MeSH terms:

Study Results

No Results Posted as of Feb 24, 2023