XEN Glaucoma Gel Stent Versus Trabeculectomy

Sponsor
Prof. Dr. Herbert Reitsamer (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT05439161
Collaborator
(none)
196
2
40

Study Details

Study Description

Brief Summary

Multicentric evaluation of best corrected visual acuity of the XEN implant versus classic trabeculectomy in open angle glaucoma subjects

Condition or Disease Intervention/Treatment Phase
  • Device: surgery
N/A

Detailed Description

The objective of this study is to evaluate the postoperative best corrected visual acuity and refraction in 2 different filtering glaucoma surgeries: XEN implant standalone procedure versus classic trabeculectomy standalone procedure. Both procedures are standard of care in surgical treatment of glaucoma. The XEN implant is a minimally invasive procedure and spares out the dissection of the conjunctiva, while the classic trabeculectomy is a procedure ab externo and supposed to be more invasive.

Up to 196 eyes will be enrolled in both surgery groups. Patients have to be legible for both procedures and are randomly allocated to both groups. Patients, who need a combined cataract procedure are not legible.

A prospective, randomized, multicenter trial. Four study centers in Europe (Austria) will participate.

Patients with open angle glaucoma will be screened for eligibility, and informed consent will be obtained from those who meet screening criteria and are interested in participating in the study. Eligible patients will be examined preoperatively to obtain a medical history and to establish a baseline for the ocular condition. During screening it will be determined via randomization if the subject will be included in group 1 where the XEN implant will be implanted in a standalone procedure or in group 2 where the trabeculectomy will be performed in a standalone procedure. Regardless of study group, all eligible patients will have the same inclusion/exclusion criteria, effectiveness endpoints and follow up exams. An inclusion of both eyes of the same patient is not possible.

Postoperatively, subjects will undergo ophthalmic evaluations at regular intervals as specified in this protocol.

The objective of this study is to evaluate the postoperative best corrected distance and near visual acuity and refraction in 2 different filtering glaucoma surgeries: XEN Implant standalone procedure versus classic trabeculectomy standalone procedure.

The primary endpoint is the proportion of patients with a best corrected distance visual acuity > 0.3 (logMAR) after 1 week.

Secondary objectives are the distance and near best corrected visual acuity measured at postoperative visits (e.g. day 1, month 1, 3, 12) and relative change of visual acuity at postoperative visits compared to baseline in both groups (e.g. month 1). The proportion of patients with a loss of best corrected distance visual acuity ≥ 2 lines at postoperative visits (e.g. day 1), the proportion of patients with a best corrected distance visual acuity (logMAR) > 0.3 and > 0.5 will be assessed at different postoperative visits (e.g. week 1, 2, month 1 and 3). Additionally, the time of recovery of visual acuity and the postoperative changes of refraction after the procedures will be compared. Secondary endpoints also include efficacy and safety of both procedures.

Subjects will undergo study visits at the following times: Preoperative Visit 1 (Screening), Operative Visit 2, 1 Day, 1 Week, 2 Weeks, 1 Month, 3, 6 Months, 12 Months Visit.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
196 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
Multicentric Evaluation of Best Corrected Visual Acuity of the XEN Implant Versus Classic Trabeculectomy in Open Angle Glaucoma Subjects
Anticipated Study Start Date :
Aug 1, 2022
Anticipated Primary Completion Date :
Apr 1, 2025
Anticipated Study Completion Date :
Dec 1, 2025

Arms and Interventions

Arm Intervention/Treatment
Active Comparator: XEN Glaucoma Gel Microstent (AbbVie) Device

Implantation of XEN Glaucoma Gel Microstent (Device, AbbVie) for the treatment of glaucoma will be performed in this arm. It is a newer filtering glaucoma surgery. XEN Glaucoma Gel Microstent implantation accounts to the filtering glaucoma surgeries.

Device: surgery
2 types of filtering glaucoma surgeries (classic trabeculectomy as gold standard, and newer XEN glaucoma microstent) are compared against each other in a prospective multicentric randomized study

Active Comparator: Trabeculectomy

Trabeculectomy will be performed in this arm. Trabeculecomy is the classic filtering glaucoma surgery since more than 50 years for the treatment of glaucoma (gold standard within the filtering glaucoma surgery group).

Device: surgery
2 types of filtering glaucoma surgeries (classic trabeculectomy as gold standard, and newer XEN glaucoma microstent) are compared against each other in a prospective multicentric randomized study

Outcome Measures

Primary Outcome Measures

  1. Best Corrected Distance Visual Acuity at 1 Week [Week 1]

    The primary endpoint is the proportion of patients with a best corrected distance visual acuity > 0.3 (logMAR) after 1 week.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. Diagnosis of open angle glaucoma (Primary open angle glaucoma, Pseudoexfoliation glaucoma, Pigmentary dispersion glaucoma)

  2. Clinically eligible for both surgeries (Trabeculectomy and XEN) on the discretion of the surgeon (area of healthy, free and mobile conjunctiva in the superior nasal target quadrant)

  3. VA logMAR ≤ 1 (VA dec ≥ 0.1)

  4. Trabecular meshwork must be visible (with Shaffer angle grade > 1 in the target quadrant)

  5. Age 18 years or older

  6. Patient understands the nature of the procedure, is willing to comply with associated follow-up evaluations, and provides written informed consent

Exclusion Criteria:
  1. Clinical significant cataract

  2. Subject has had prior cataract surgery in study eye ≤ 1 months (count to operation)

  3. Subject has had prior (incisional) glaucoma surgery (XEN, trabeculectomy, viscocanalostomy, canaloplasty, shunts of any type, collagen implants, etc.). Prior iridotomy is acceptable.

  4. Phacic Angle Closure Glaucoma

  5. Subject has neovascular, uveitic or angle recession glaucoma or any glaucoma associated with vascular disorders

  6. Active inflammation (e.g., blepharitis, conjunctivitis, keratitis, uveitis)

  7. Anterior chamber intraocular lens

  8. Vitreous present in the anterior chamber

  9. Presence of intraocular silicone oil

  10. History of corneal surgery, corneal opacities, or corneal disease

  11. Impaired episcleral venous drainage (e.g. Sturge-Weber or nanophthalmos)

  12. History of dermatologic keloid formation

  13. Active diabetic retinopathy, proliferative retinopathy, choroidal neovascularization, branch retinal vein occlusion, central retinal vein occlusion, or other ophthalmic disease or disorder that could confound study results

  14. Known or suspected allergy or sensitivity to drugs required for the surgical procedure or any of the device components (e.g., porcine products or glutaraldehyde),

  15. Pregnant or nursing women

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • Prof. Dr. Herbert Reitsamer

Investigators

  • Study Chair: Herbert Reitsamer, MD, Paracelsus Medical University Salzburg/ Salzburger Landeskliniken

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Prof. Dr. Herbert Reitsamer, Prof. Dr. Herbert Reitsamer, Paracelsus Medical University
ClinicalTrials.gov Identifier:
NCT05439161
Other Study ID Numbers:
  • A.08242018-v2.15122021
First Posted:
Jun 30, 2022
Last Update Posted:
Jun 30, 2022
Last Verified:
Jun 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jun 30, 2022