MACROS2: Pragmatic Randomised Trial of the ESC 0/1 Versus 0/3 Hour Troponin Pathway

Sponsor
Liverpool University Hospitals NHS Foundation Trust (Other)
Overall Status
Recruiting
CT.gov ID
NCT05322395
Collaborator
northwest coast academic science network (Other), Quidel Corporation (Industry), Siemens Corporation, Corporate Technology (Industry), Abbott Diagnostics Division (Industry)
3,536
1
2
25
141.4

Study Details

Study Description

Brief Summary

The primary objective of this study is to assess the feasibility and impact of implementing the ESC 0-1 hour high sensitive troponin pathway in clinical practice and with specific reference to the 0-3 hour pathway currently in use.

The principal outcome measure will be the safety of the 0-1 hour protocol (which is less established and has limited data on safety when implemented in clinical practice)

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: ESC 0/1 hour troponin pathway
N/A

Detailed Description

  1. the investigators propose to compare 2 'gold standard' NICE recommended/ESC guideline-backed pathways; the accelerated 0-1 hour troponin clinical pathway versus the conventional 0-3-hour pathway, in a randomised multicentre controlled study.

  2. The primary outcome is to compare percentage safe (with the emphasis and sample size calculation on safety) discharge by 4 hours from presentation by means of the 0-3 hours versus the 0-1-hour (with the 0 hour in both pathways incorporating discharge using the limit of detection).

  3. the investigators propose to use high sensitivity troponin T (hs cTnT) (ROCHE, Elecsys assay as this is currently in routine clinical use at the site) for this purpose and also perform comparative analyses using a high sensitivity troponin I (hs cTnI) assay (ABBOTT, Architect).

  4. Redundant blood sample will also be used to evaluate point of care testing (POCT), with additional blood sample taken for POC. These samples will be undertaken as part of routine clinical care and will not require additional venepuncture (and will only be analysed if consent is gained for tissue use in research) population. A co-primary endpoint will be single sample rule-out by point of care troponin (POCT) (with a value of <4ng/l in those with chest pain onset >3 hours from presentation) as assessed in the recent APACE study of triage true POC.11 A comparison of this rule-out in terms of effectiveness (percentage discharge) and safety (sensitivity) will be made with ROCHE lod (<5ng/l)12 and the optimised rule-out of Abbott architect (HSTNI<5ng/l)13

2.2 Secondary objectives

  1. The relative performance of the Abbott Architect high sensitivity troponin I (hs TnI) , Quidel's TriageTrue and Siemens Attellica troponin I assay will also be assessed in terms of the primary and secondary endpoints by reference to high sensitivity troponin T (hs cTnT) with cut-points for Abbott hs-cTn I from the BACC study used for the 0-1-hour pathway.14

  2. The performance of the novel machine learning algorithm, the Myocardial Ischemic Injury Index (MI3, Abbott) will also be assessed retrospectively with regard to safety and efficacy. This sub study using fully anonymized data will be performed in association with coinvestigators from Abbott Diagnostics (appendix 1).

  3. To understand if low levels of Growth Differentiation Factor (GDF-15), could expand safe discharge beyond the LOD. This will be tested for retrospectively in stored plasma samples.

  4. To assess if point of care troponin samples at time points at 1 to 3 hours (additional samples) mirror gold standard high sensitive troponin analysis with respect to diagnosis of acute or chronic myocardial injury and/or type 1 or type 2 myocardial infarction.

  1. Hypothesis That an accelerated 0-1-hour troponin protocol, when implemented into clinical practice as a pragmatic RCT, will effect safe discharge with greater numbers discharged, by 4 hours from presentation, compared to the use of the more conventional 0-3 hour troponin protocol.

Means to test hypothesis: A two-arm parallel group, two-centre randomised controlled trial of 0-1-hour high sensitivity troponin T (hs cTnT) compared to a 0-3-hour pathway as rules for rapid discharge of suspected ACS. (both incorporating single presentation sample limit of detection (LOD) high sensitive troponin as a rule for discharge, or cut-off selected by manufacturer).

The power of the study is on safety rather than percent discharge achieved by 4 hours as this is the primary focus for clinicians and health care institutions. (By virtue of the earlier sampling the 0-1 hour troponin sampling is likely to allow greater discharges by 4 hours and the sample size for safety easily accommodates this aspect).

  1. Outcomes: 4.1 Primary endpoint
  1. the investigators will compare safe discharge by each strategy (ie the ESC 0-1 hour pathway versus 0-3 pathway) and the proportion actually discharged by each pathway at 4 hours. The exact definition of safety will be percentage (of cohort randomised to each pathway) safely discharged by 4 hours of presentation to accident and emergency (Safety will be judged by type 1 myocardial infarction, cardiovascular death by 4 weeks with sensitivity

98% - the study will be powered on safety to establish whether 0-1-hour performance is equivalent to 0-3-hour sampling by means of a non-inferiority analysis- see statistics).

(Type 1 myocardial infarction is due to acute coronary atherothrombotic myocardial injury with either plaque rupture or erosion and, often, associated thrombosis. A separate analysis will also be undertaken with inclusion of type 2 MI as well as type 1 MI as an endpoint

4.2 Co-primary endpoint: There will be a comparison of the real time performance of point of care troponin (POCT) assay to that of a sample sent for analysis in the laboratory (the current gold standard of central laboratory analysis using HS cTn).The primary interest will be in presentation sample POC rule-out (triage true (quidel) POC <4ng/l with CP onset >3 hours compared to LOD or optimised rule-out of ROCHE (elecsys) assay, siemens attelica and Abbott architect. There will be a similar comparison made with siemens VTLI troponin I POC assay using FDA approved cut-points for MI rule-out

4.3 Secondary Endpoints:

  1. Type 1 myocardial infarction (adjudicated with the use of Abbott hs cTnI) and cardiovascular death* at 4 weeks (target for safety negative predictive value (NPV)

99.5% and sensitivity >98%). (co-primary endpoint). This analysis will be repeated incorporating both type 1 and 2 MI definition. (prespecified secondary analysis)

  1. All cause death, type 1 myocardial infarction and urgent or emergency revascularisation. This analysis will be repeated incorporating both type 1 and 2 MI definition. (prespecified secondary analysis)

  2. Proportion with rule-out or rule-in MI in the 0-1 hour and 0-3 hour

  3. Prediction of MI with myocardial ischemic injury index (MI3) algorithm9

  4. HEART ≤3 and a modified HEART score for rule-out MI at 30 days15

  5. Proportion with repeat presentations to accident and emergency within 30 days

  6. Proportion undergoing coronary angiography and coronary revascularisation in 0-1 versus 0-3 hour pathway

  7. Performance of point of care troponin samples at time points at 1 to 3 hours (additional samples to 0 hour) with respect to diagnosis of acute or chronic myocardial injury and/or type 1 myocardial infarction

  8. Rule out of MI with GDF-15 (Growth Differentiation Factor 15)

  • Cardiovascular deaths include deaths that result from an myocardial infarctions (MI), sudden cardiac death, death due to heart failure (HF), death due to stroke, death due to cardiovascular procedures, death due to cardiovascular haemorrhage, and death due to other cardiovascular causes and deaths that do not have a clear non- cardiovascular cause.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
3536 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Intervention Model Description:
A two-arm parallel group, two-centre randomised controlled trial of 0-1-hour high sensitivity troponin T (hs cTnT) compared to a 0-3-hour pathway as rules for rapid discharge of suspected ACS. (both incorporating single presentation sample limit of detection (LOD) high sensitive troponin as a rule for discharge, or cut-off selected by manufacturer). The power of the study is on safety rather than percent discharge achieved by 4 hours as this is the primary focus for clinicians and health care institutions. (By virtue of the earlier sampling the 0-1 hour troponin sampling is likely to allow greater discharges by 4 hours and the sample size for safety easily accommodates this aspect).A two-arm parallel group, two-centre randomised controlled trial of 0-1-hour high sensitivity troponin T (hs cTnT) compared to a 0-3-hour pathway as rules for rapid discharge of suspected ACS. (both incorporating single presentation sample limit of detection (LOD) high sensitive troponin as a rule for discharge, or cut-off selected by manufacturer). The power of the study is on safety rather than percent discharge achieved by 4 hours as this is the primary focus for clinicians and health care institutions. (By virtue of the earlier sampling the 0-1 hour troponin sampling is likely to allow greater discharges by 4 hours and the sample size for safety easily accommodates this aspect).
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Safety and Feasibility of Triage and Rapid Discharge of Patients With Chest Pain From Accident and Emergency: a Pragmatic, Randomised, Multicentre, Non-inferiority Control Trial of the Accelerated European Society of Cardiology (ESC) 0-1 Hour Pathway vs. Conventional 0-3 Hour Accelerated Diagnostic Protocol.
Actual Study Start Date :
Dec 10, 2021
Anticipated Primary Completion Date :
Dec 10, 2023
Anticipated Study Completion Date :
Jan 10, 2024

Arms and Interventions

Arm Intervention/Treatment
Experimental: ESC 0/1 pathway

A two-arm parallel group, two-centre pragmatic randomised controlled trial of 0-1-hour high sensitivity troponin T (hs cTnT) compared to a 0-3-hour pathway as rules for rapid discharge of suspected ACS. (both incorporating single presentation sample limit of detection (LOD) high sensitive troponin as a rule for discharge, or cut-off selected by manufacturer). The power of the study is on safety rather than percent discharge achieved by 4 hours as this is the primary focus for clinicians and health care institutions. (By virtue of the earlier sampling the 0-1 hour troponin sampling is likely to allow greater discharges by 4 hours and the sample size for safety easily accommodates this aspect).

Diagnostic Test: ESC 0/1 hour troponin pathway
randomisation to 0/1 versus 0/3 hour pathway
Other Names:
  • esc 0/3 hour troponin pathway
  • Active Comparator: ESC 0/3 hour pathway

    A two-arm parallel group, two-centre pragmatic randomised controlled trial of 0-1-hour high sensitivity troponin T (hs cTnT) compared to a 0-3-hour pathway as rules for rapid discharge of suspected ACS. (both incorporating single presentation sample limit of detection (LOD) high sensitive troponin as a rule for discharge, or cut-off selected by manufacturer). The power of the study is on safety rather than percent discharge achieved by 4 hours as this is the primary focus for clinicians and health care institutions. (By virtue of the earlier sampling the 0-1 hour troponin sampling is likely to allow greater discharges by 4 hours and the sample size for safety easily accommodates this aspect).

    Diagnostic Test: ESC 0/1 hour troponin pathway
    randomisation to 0/1 versus 0/3 hour pathway
    Other Names:
  • esc 0/3 hour troponin pathway
  • Outcome Measures

    Primary Outcome Measures

    1. percentage safe discharge by 4 hours. safety defined as type 1 MI and CV deah [4 hours]

      We will compare safe discharge by each strategy (ie the ESC 0-1 hour pathway versus 0-3 pathway) and the proportion actually discharged by each pathway at 4 hours. The exact definition of safety will be percentage (of cohort randomised to each pathway) safely discharged by 4 hours of presentation to accident and emergency (Safety will be judged by type 1 myocardial infarction, cardiovascular death by 4 weeks with sensitivity >98% - the study will be powered on safety to establish whether 0-1-hour performance is equivalent to 0-3-hour sampling by means of a non-inferiority analysis- see statistics). (Type 1 myocardial infarction is due to acute coronary atherothrombotic myocardial injury with either plaque rupture or erosion and, often, associated thrombosis. A separate analysis will also be undertaken with inclusion of type 2 MI as well as type 1 MI as an endpoint

    2. point of care troponin performance compared to laboratory performance [4 hours]

      largely rule-out of Quidel triage true and siemens VTLI

    Secondary Outcome Measures

    1. Type 1 myocardial infarction [30 days]

    2. All cause death, type 1 myocardial infarction and urgent or emergency revascularisation. This analysis will be repeated incorporating both type 1 and 2 MI definition. (prespecified secondary analysis) [30 days]

    3. Proportion with rule-out or rule-in MI in the 0-1 hour and 0-3 hour [30 days]

    4. Prediction of MI with myocardial ischemic injury index (MI3) algorithm [30 days]

    5. HEART ≤3 and a modified HEART score for rule-out MI at 30 days [30 days]

    6. Proportion with repeat presentations to accident and emergency within 30 days [30 days]

    7. Proportion undergoing coronary angiography and coronary revascularisation in 0-1 versus 0-3 hour pathway [1 year]

    8. Performance of point of care troponin samples at time points at 1 to 3 hours (additional samples to 0 hour) with respect to diagnosis of acute or chronic myocardial injury and/or type 1 myocardial infarction [30 days]

    9. Rule out of MI with GDF-15 (Growth Differentiation Factor 15) [30 days]

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Chest pain with moderate or high suspicion chest pain (see chest pain evaluation chart at end) or any patient the clinician deems suspicious for myocardial ischaemia thus requesting a troponin sample (between daytime hours 0800hrs to 1800hrs)

    • Presentation <12 hours since onset of chest pain (or unknown duration)

    • Age >18 years of age

    Exclusion Criteria:
    • ST elevation myocardial infarction (STEMI) infarct on the presenting electrocardiogram (ECG)

    • Symptoms considered definitely non-cardiac

    • Trauma

    • Pregnancy

    • Comorbid conditions requiring hospital admission

    • Coronary artery bypass graft surgery (CABG) <1 month

    • coexistent clinical conditions likely to preclude follow-up.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 liverpool university Hospital nhs foundation trust Liverpool GB United Kingdom L186JR

    Sponsors and Collaborators

    • Liverpool University Hospitals NHS Foundation Trust
    • northwest coast academic science network
    • Quidel Corporation
    • Siemens Corporation, Corporate Technology
    • Abbott Diagnostics Division

    Investigators

    • Study Director: Heather Rodgers, Liverpool University Hospitals NHS Foundation Trust

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Liverpool University Hospitals NHS Foundation Trust
    ClinicalTrials.gov Identifier:
    NCT05322395
    Other Study ID Numbers:
    • SPO635
    First Posted:
    Apr 11, 2022
    Last Update Posted:
    Apr 11, 2022
    Last Verified:
    Dec 1, 2021
    Individual Participant Data (IPD) Sharing Statement:
    Undecided
    Plan to Share IPD:
    Undecided
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by Liverpool University Hospitals NHS Foundation Trust
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Apr 11, 2022