Tolerability and Background Fluorescence of the MediBeacon Transdermal GFR Measurement System

Sponsor
MediBeacon (Industry)
Overall Status
Completed
CT.gov ID
NCT03810833
Collaborator
(none)
12
1
1
7
52.2

Study Details

Study Description

Brief Summary

This study is designed to evaluate background fluorescence of participants of different ages, gender, and skin color. In addition, 48-hour tolerability of the sensor and adhesive will be evaluated.

Condition or Disease Intervention/Treatment Phase
  • Device: Brilliance device sensor
N/A

Detailed Description

The MediBeacon Transdermal GFR Measurement System investigational is intended to measure the Glomerular Filtration Rate (GFR) in patients with normal or impaired renal function by noninvasively monitoring fluorescent light emission from an exogenous tracer agent (MB-102) over time. The device utilized in this study is the Brilliance device. Approximately 1 male and 1 female from each age cohort (18-50 years; 51+ years) and clustered Fitzpatrick Skin Scale groups (I-II [Light, pale white; white, fair]; III-IV [Medium, white to olive; olive, moderate brown]; and V-VI [Brown, dark brown; black, very dark brown to black]) will be recruited, for a total of 12 participants. Participants will have Brilliance device sensors placed on two locations on their skin, which will remain for 48 hours. The sensor location will be prepared through shaving and cleaning (as applicable), placed on the skin via standard single-use adhesive pads, and baseline measurements collected. Participants may undergo activities of daily living while measurements are being collected. Light pressure and other minor perturbations may be applied to the sensors to evaluate the effect on background fluorescence. Adverse events associated with sensor placement (such as skin irritations) will be recorded.

Study Design

Study Type:
Interventional
Actual Enrollment :
12 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Device Feasibility
Official Title:
A Study of Tolerability and Background Fluorescence of the MediBeacon Transdermal GFR Measurement System
Actual Study Start Date :
Sep 16, 2019
Actual Primary Completion Date :
Sep 23, 2019
Actual Study Completion Date :
Sep 23, 2019

Arms and Interventions

Arm Intervention/Treatment
Experimental: Participants with Brilliance sensor placement

Brilliance device sensors placed on the left and right pectoralis major, remaining for 48 hours

Device: Brilliance device sensor
Two separate sensors will be attached via standard, single-use adhesive pads to the left and right pectoralis major on each participant.

Outcome Measures

Primary Outcome Measures

  1. Mean Background Fluorescence [From the time of sensor placement to 48 hours after placement]

    Two separate Brilliance device sensors will be attached via standard adhesive pads to the left and right pectoralis major on each participant. Fluorescence measurements will be collected directly by the MediBeacon Transdermal GFR Measurement System Brilliance device, and will be continuously collected throughout the 48 hour study.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 99 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Healthy male and female adults age 18 and older

  • 2 age cohorts to be recruited: 18 - 50 years of age and 51+ years or older

  • Skin color groups to be recruited in accordance with the Fitzpatrick Skin Scale (I - VI)

  • Participants willing to sign the Institutional Review Board (IRB) approved informed consent form prior to the initiation of any study specific procedures.

Exclusion Criteria:
  • History of skin sensitivity to adhesives (e.g. Band-Aids, surgical tape)

  • Any characteristics which, in the opinion of the investigator, makes the participant a poor candidate for participation in the clinical trial

  • Significant scarring, tattoos or alterations in pigmentation on the standardized sensor locations that would alter sensor readings versus other areas of the skin

Contacts and Locations

Locations

Site City State Country Postal Code
1 St. Louis Clinical Trials Saint Louis Missouri United States 63141

Sponsors and Collaborators

  • MediBeacon

Investigators

  • Study Director: Richard B Dorshow, PhD, MediBeacon

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
MediBeacon
ClinicalTrials.gov Identifier:
NCT03810833
Other Study ID Numbers:
  • ORFM Sensor 100-01
First Posted:
Jan 22, 2019
Last Update Posted:
Jan 10, 2020
Last Verified:
Jan 1, 2020
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
Yes
Keywords provided by MediBeacon
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jan 10, 2020