Ankura™ TAA Stent Graft System Post-Market Clinical Follow-up Study

Sponsor
Lifetech Scientific (Shenzhen) Co., Ltd. (Industry)
Overall Status
Not yet recruiting
CT.gov ID
NCT05639569
Collaborator
(none)
145
8
60
18.1
0.3

Study Details

Study Description

Brief Summary

The purpose of this study is to collect clinical data on patient outcomes, evaluate the safety and performance of AnkuraTM TAA Stent Graft System and SurpassTM Super Stiff Guidewire, and build clinical evidence for patients with Descending Thoracic Aneurysm (DTA) or Type B Aortic Dissection (TBAD).

Condition or Disease Intervention/Treatment Phase
  • Device: Ankura™ TAA Stent Graft Systems

Detailed Description

The study is a multi-center, multi-national, prospective, observational, post-market clinical follow-up study conducted in 14 investigational centers.

Study Design

Study Type:
Observational
Anticipated Enrollment :
145 participants
Observational Model:
Other
Time Perspective:
Prospective
Official Title:
Ankura™ TAA Stent Graft System Post-Market Clinical Follow-up Study -- Multi-center, Prospective, Observational, Post-Market Follow-up Study
Anticipated Study Start Date :
Dec 30, 2022
Anticipated Primary Completion Date :
Dec 30, 2024
Anticipated Study Completion Date :
Dec 30, 2027

Arms and Interventions

Arm Intervention/Treatment
Patients with Descending Thoracic Aneurysm (DTA) or Type B Aortic Dissection (TBAD)

All patients who signed informed consent and are used with Ankura™ TAA Stent Graft Systems will undergo follow-up (FU) evaluations as per local hospital standards and corresponding IFU which is expected to be at the following time points post-implant: Before discharge, 30days after the procudure, 3-6 months after the Procedure, 12 months after the procedure, 24 months after the procedure, 36 months after the procedure

Device: Ankura™ TAA Stent Graft Systems
All patients will be implanted with Ankura™ TAA Stent Graft Systems in accordance with the instructions for use (IFU).

Outcome Measures

Primary Outcome Measures

  1. Incidence of major adverse events [Timeframe: within 30-day post-implantation]

    Incidence of major adverse events.

  2. Freedom from stent graft-related events [Timeframe: within 12-month post-implantation]

    Freedom from stent graft-related events (12 months)

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 85 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Patient has descending thoracic aortic aneurysm (DTA) or type B aortic dissection (TBAD), who needs endovascular repair (TEVAR).

  • Life expectancy > 1 year.

  • Patient or legally authorized representative understands the nature of the clinical trial, agrees to its provisions, agrees to comply with the requirements of the study including a 3-year follow-up, and signed applicable Informed Consent Form.

  • Patient's characteristics consistent with Ankura™ Stent Graft System IFU and sizing guidelines, which indicate as following:

  1. For descending thoracic aortic aneurysm (DTA) patient:
  • Adequate iliac/femoral access vessel that is compatible with the required delivery system.

  • Aortic inner diameter in the range of 18-42mm.

  • ≥15mm non-aneurysmal aorta proximal and distal to the lesion.

  • Morphology suitable for endovascular repair.

  1. For type B aortic dissection (TBAD) patient:
  • Adequate iliac/femoral access vessel that is compatible with the required delivery system.

  • ≥15mm landing zone proximal to the primary entry tear; proximal extent of the landing zone must not be dissected. Diameter at proximal extent of proximal landing zone in the range of 16-44mm.

  • ≥15mm landing zone distal to the primary entry tear; distal extent of the landing zone must not be dissected. Diameter at distal extent of distal landing zone in the range of 16-44mm.

  • Morphology suitable for endovascular repair.

Exclusion Criteria:
  • Patient with any contraindications mentioned in the Ankura™ Stent Graft System IFU:

  • Patients with acute systemic infection;

  • Patients who have had other devices implanted in the cardiovascular cavity, which will interfere with the placement of this device;

  • Patients with mesenteric blood flow mainly supplied by the inferior mesenteric artery;

  • Patients who have allergic reaction to the device;

  • Patients who are not suitable for endovascular repair in vascular morphology;

  • Patients who cannot tolerate contrast agents due to severe renal insufficiency;

  • Patients who are allergic to contrast agents;

  • Aneurysms neck with thrombus;

  • Non-aneurysmal aortic proximal neck length <1.5cm;

  • Non-aneurysmal aortic distal anchorage zone <1.5cm;

  • For aneurysms, Non-aneurysmal aortic diameter <18mm or >42mm. For Type B dissections, Non-aneurysmal aortic diameter <16mm or >44mm.

  • Patient with traumatic aortic injury;

  • Patient with uncorrectable coagulopathy;

  • Patient with hereditary connective tissue disease, including but not limited to Marfan Syndrome or Ehlers-Danlos Syndrome;

  • Patient with morbid obesity, weight greater than 350 Pounds (150kg), or who cannot undergo accurate fluoroscopy examination due to obesity;

  • Age<18 Years or Age> 85 Years;

  • Pregnant or plan to be pregnant or breast feeding;

  • Myocardial infarction or stroke within 3 months prior to the procedure;

  • American Society of Anesthesiologists Physical Status Classification (ASA) classification 5 or higher;

  • Patient with an unstable angina pectoris or hearth insufficiency New York Heart Association Functional Classification (NYHA) 3 or 4

  • Participant in other drug or medical device clinical trials;

  • Patient with access vessel which are to tortuous, narrow or any kind of reasons that would lead to failure of introduction and advancing an introducer sheath;

  • Any condition (medical or anatomic) which makes the patient not suitable for endovascular repair according to the opinion of the investigator.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Hospital Espanol de Mendoza Mendoza Argentina
2 Asklepios Klinik Nord Heidberg Hamburg Germany
3 St. Franziskus Hospital Münster Muenster Germany
4 LMU Klinikum Munich Germany
5 Evaggelismos General Hospital Athens Greece
6 University General Hospital - Attikon Athens Greece
7 Hospital S. Martino Genova Italy
8 Hospital Mauriziano Turin Italy

Sponsors and Collaborators

  • Lifetech Scientific (Shenzhen) Co., Ltd.

Investigators

  • Principal Investigator: Jan Stana, LMU Munich

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Lifetech Scientific (Shenzhen) Co., Ltd.
ClinicalTrials.gov Identifier:
NCT05639569
Other Study ID Numbers:
  • LT/TS/12C-2021-01
First Posted:
Dec 6, 2022
Last Update Posted:
Dec 6, 2022
Last Verified:
Nov 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Dec 6, 2022