Prizvalve Pro™ Transcatheter Aortic Valve Replacement Study

Sponsor
Shanghai NewMed Medical Co., Ltd. (Industry)
Overall Status
Not yet recruiting
CT.gov ID
NCT05864456
Collaborator
The General Hospital of Northern Theater Command (Other), West China Hospital (Other)
73
1
1
60
1.2

Study Details

Study Description

Brief Summary

The purpose of this clinical trial is to evaluate the safety and efficacy of the Prizvalve Pro™ transcatheter aortic valve system in the treatment of patients with severe aortic stenosis who are at high risk of surgery or who are not suitable for surgery.

Condition or Disease Intervention/Treatment Phase
  • Device: Prizvalve Pro™ transcatheter aortic valve system
N/A

Detailed Description

This study is a multicenter, single-arm, prospective clinical study.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
73 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
Evaluation of the Safety and Efficacy of the Prizvalve Pro™ Transcatheter Aortic Valve System in the Treatment of Patients With Severe Aortic Valve Stenosis Disease at High Surgical Risk
Anticipated Study Start Date :
May 1, 2023
Anticipated Primary Completion Date :
Jun 1, 2024
Anticipated Study Completion Date :
May 1, 2028

Arms and Interventions

Arm Intervention/Treatment
Experimental: Transcatheter aortic valve replacement

Transcatheter aortic valve replacement with Prizvalve Pro™ transcatheter aortic valve system

Device: Prizvalve Pro™ transcatheter aortic valve system
Transcatheter Aortic Valve Replacement

Outcome Measures

Primary Outcome Measures

  1. Composite endpoint event rate at 30 days [30 days after procedure]

    Composite endpoint event includes all-cause death, stroke, myocardial infarction, permanent pacemaker implantation, serious vascular and access-related complications, surgical intervention for aortic valve reoperation, valve-in-valve surgery.

Secondary Outcome Measures

  1. Device success rate [Immediately after procedure]

    Device success is defined as The device enters the vascular approach, be transported, released and implanted successfully, and the delivery system is removed from the body successfully; The implanted valve achieves the desired efficacy (mean transvalvular pressure difference <20 mmHg or peak flow velocity <3 m/s in the aortic valve, no severe prosthetic aortic regurgitation or perivalvular leak).

  2. Procedural success rate [Immediately after procedure]

    Procedure success is defined as Implantation of ≤2 valves, with the implanted valves placed in the appropriate anatomic position; No intraoperative or immediate postoperative mortality; The intended purpose of the procedure was achieved without serious intraoperative complications (coronary occlusion, septal perforation, mitral valve damage or incompetence, pericardial tamponade, surgical termination, and open-heart surgical treatment for cardiac surgery).

  3. Delivery system and component performance evaluation [Immediately after procedure]

    Delivery system performance evaluation includes delivery, transvalve, release positioning, balloon filling and retrieval, visibility, and retrieval performance. (For each assessment: 1-4 points;1=excellent, 2=good, 3=fair, 4=poor).

  4. Valve function [Immediately after procedure, 1 day of discharge, 30 days, 1 year]

    Valve function includes aortic orifice area, transvalvular pressure difference, valvular regurgitation, and perivalvular leakage.

  5. Improvement in cardiac function [1 day of discharge, 30 days, 1-5 year]

    Cardiac function is based on the New York Heart Association (NYHA) classification scheme.

  6. Improvement in quality of life [30 days, 1 year]

    The SF-12 rating scale is used to assess quality of life.

  7. Incidence of all-cause mortality [Immediately after procedure, 1 day of discharge, 30 days, 1-5 year]

    Rate of all-cause mortality during the trial. All-cause mortality includes cardiovascular morality and non-cardiovascular morality.

  8. Incidence of myocardial infarction [Immediately after procedure, 1 day of discharge, 30 days, 1-5 year]

    Rate of patients with myocardial infarction during the trial.

  9. Incidence of disabling stroke [1 day of discharge, 30 days, 1-5 year]

    Rate of patients with disabling stroke during the trial.

  10. Incidence of permanent pacemaker implantation [1 day of discharge, 30 days, 1-5 year]

    Rate of patients with permanent pacemaker implantation during the trial.

  11. Incidence of serious vascular and access-related complications [Immediately after procedure, 1 day of discharge, 30 days, 1-5 year]

    Rate of patients with serious vascular and access-related complications during the trial.

  12. Incidence of serious bleeding [1 day of discharge, 30 days, 1-5 year]

    Rate of patients with serious bleeding during the trial.

  13. Incidence of acute kidney injury [1 day of discharge, 30 days, 1-5 year]

    Rate of patients with acute kidney injury during the trial.

  14. Incidence of major cardiovascular and cerebrovascular adverse events [1 day of discharge, 30 days, 1-5 year]

    Incidence of MACCE during the trial. MACCE is defined as death, stroke, myocardial infarction, arrhythmia, conduction block, and aortic valve reoperation (interventional or surgical).

  15. Incidence of other TAVI-related complications [Immediately after procedure, 1 day of discharge, 30 days, 1-5 year]

    Rate of patients with other TAVI-related complications during the trial. Other TAVI-related complications include conversion to surgery, valve-in-valve implantation, accidental cardiopulmonary mechanical assistance, coronary occlusion, ventricular septal perforation, mitral valve damage or loss of function, pericardial tamponade, endocarditis, valvular thrombosis, valvular ectopic (migration, embolization, erroneous release), etc.

Eligibility Criteria

Criteria

Ages Eligible for Study:
65 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. Age ≥ 65 years ;

  2. Patients with symptomatic severe aortic valve stenosis (evaluated by echocardiography: transaortic valve pressure gradient ≥40mmHg (1mmHg=0.133kPa), or transaortic valve blood flow rate ≥4m/s, or aortic Valve area<1.0cm², or AVA <0.5cm² /m²);

  3. Cardiac function NYHA ≥ II;

  4. Life expectancy> 12 months;

  5. Patients who are anatomically suitable for transcatheter aortic valve implantation;

  6. Patients who have been evaluated by two or more cardiovascular surgeons as unsuitable for conventional surgery; or patients who have refused conventional surgery after adequate communication from the surgeon and who are at high risk for conventional surgery;

  7. Patients who can understand the purpose of the trial and volunteer to participate in, sign the informed consent form and are willing to accept relevant examinations and clinical follow-ups.

Exclusion Criteria:
  1. Acute myocardial infarction occurred within 1 month before this treatment;

  2. Congenital unicuspid aortic valve;

  3. Any therapeutic cardiac operation that is performed within 30 days of the index procedure (Previous PCI or implantation of a permanent pacemaker are not considered exclusion criteria);

  4. Patients with other prosthetic heart valves, prosthetic rings already implanted in the heart, or severe mitral valve closure insufficiency (>3+);

  5. Patients with hematologic disorders or abnormalities that make surgical treatment inappropriate;

  6. Untreated severe coronary artery stenosis that requires revascularization;

  7. Patients with hemodynamic or respiratory instability, requiring continuous mechanical heart assistance or mechanical ventilation;

  8. Patients who need emergency surgery for any reason;

  9. Patients with hypertrophic cardiomyopathy with obstruction;

  10. Severe left ventricular dysfunction, left ventricular ejection fraction (LVEF) <20%;

  11. Echocardiographic evidence of intracardiac mass, thrombus or vegetation;

  12. Patients with left ventricular outflow tract obstruction;

  13. A history of acute peptic ulcer or upper gastrointestinal bleeding within 3 months;

  14. Patients who are allergy or resistance to cobalt-chromium alloy, contrast agents and related components;

  15. Patients who are unable to receive anticoagulation or antiplatelet therapy;

  16. Cerebrovascular accident occurred within 3 months, not including transient ischemic attack;

  17. Severe aortic diseases, including abdominal aortic or thoracic aortic aneurysm, etc;

  18. Active infective endocarditis or other active infections;

  19. Patients who have participated in clinical trials of other drugs or medical devices before enrollment and have not yet reached the primary outcome of research;

  20. The investigator judged that patient with poor compliance and could not complete the study as required.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Shanghai NewMed Medical Co., Ltd. Shanghai China

Sponsors and Collaborators

  • Shanghai NewMed Medical Co., Ltd.
  • The General Hospital of Northern Theater Command
  • West China Hospital

Investigators

  • Study Chair: Yaling Han, Professor, Principal coordinating investigator
  • Principal Investigator: Mao Chen, Professor, coordinating investigator
  • Study Director: Kai Xu, Professor, coordinating investigator

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Shanghai NewMed Medical Co., Ltd.
ClinicalTrials.gov Identifier:
NCT05864456
Other Study ID Numbers:
  • Prizvalve Pro-2023
First Posted:
May 18, 2023
Last Update Posted:
May 19, 2023
Last Verified:
May 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of May 19, 2023