Transcranial Magnetic Stimulation (TMS) to Treat Depression in Autism Spectrum Disorder

Sponsor
Yale University (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT06142955
Collaborator
(none)
60
1
8
36
1.7

Study Details

Study Description

Brief Summary

This study will assess clinical and behavioral measures along with electroencephalogram (EEG), event-related potentials (ERPS), and eye-tracking (ET) prior to and following a single intermittent Theta Burst Stimulation (iTBS) session to provide preliminary insight into the potential of TMS as an intervention for depression in individuals with Autism Spectrum Disorder (ASD).

Condition or Disease Intervention/Treatment Phase
  • Device: MAGSTIM Rapid2 TMS system
N/A

Detailed Description

Participants will complete two separate sessions, approximately one week apart, with each session including: 1) a baseline assessment of neuropsychological, cognitive and behavioral function, 2) neural and visual attentional social response (EEG/ET paradigm), 3) a single iTBS session or sham stimulation to the left DLPFC, and 4) poststimulation assessment of neural and visual attentional social response (EEG/ET paradigm). The order of active stimulation versus sham will be randomized such that half of the participants in each group get the sham stimulation during the first session and half will get active stimulation in the first session then crossover. EEG and eye-tracking will take approximately 60-minutes and will be collected pre-and-post TMS administration.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
60 participants
Allocation:
Randomized
Intervention Model:
Crossover Assignment
Intervention Model Description:
Typically developing (TD) controls and ASD participants with and without depression will receive both active and sham TMS in a randomized crossover assignment involving two study sessions.Typically developing (TD) controls and ASD participants with and without depression will receive both active and sham TMS in a randomized crossover assignment involving two study sessions.
Masking:
Double (Participant, Care Provider)
Primary Purpose:
Prevention
Official Title:
Neuromodulation for Depression in Autism Spectrum Disorder
Anticipated Study Start Date :
Dec 1, 2023
Anticipated Primary Completion Date :
Dec 1, 2026
Anticipated Study Completion Date :
Dec 1, 2026

Arms and Interventions

Arm Intervention/Treatment
Experimental: ASD with depression, iTBS then Sham

Participants having ASD with depression will undergo EEG and ET with TMS prior to and following a single iTBS session. Participants first received iTBS then sham approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: ASD with depression, Sham then iTBS

Participants having ASD with depression will undergo EEG and ET with TMS prior to and following a single iTBS session.Participants first received sham then iTBS approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: ASD without depression, iTBS then Sham

Participants having ASD without depression will undergo EEG and ET with TMS prior to and following a single iTBS session. Participants first received iTBS then sham approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: ASD without depression, Sham then iTBS

Participants having ASD without depression will undergo EEG and ET with TMS prior to and following a single iTBS session.Participants first received sham then iTBS approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: TD with depression, iTBS then Sham

Participants that are TD with depression will undergo EEG and ET with TMS prior to and following a single iTBS session. Participants first received iTBS then sham approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: TD with depression, Sham then iTBS

Participants that are TD with depression will undergo EEG and ET with TMS prior to and following a single iTBS session. Participants first received sham then iTBS approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: TD without depression, iTBS then Sham

Participants that are TD without depression will undergo EEG and ET with TMS prior to and following a single iTBS session. Participants first received iTBS then sham approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Experimental: TD without depression, Sham then iTBS

Participants that are TD without depression will undergo EEG and ET with TMS prior to and following a single iTBS session. Participants first received sham then iTBS approximately one week apart.

Device: MAGSTIM Rapid2 TMS system
The device will administer TMS pulses in bursts at fixed intervals for a total of 600 pulses over 190 seconds after first assessing the participants motor threshold (MT). During the sham stimulation condition, the TMS coil will be tilted 90° tangential to the scalp during the administration so that the orientation is not biologically active and will not elicit a muscle contraction. This sham condition will look and sound just like real TMS.

Outcome Measures

Primary Outcome Measures

  1. Change in Electroencephalogram (EEG) brain responses to sad faces [baseline and up to week 2]

    As measured by amplitude and latency of event related potentials (ERP) (the right lateralized P100, P200 and amplitude of N170) to sad faces. EEG: an electrophysiological assay that measures brain activity from the scalp.

  2. Change in eye tracking (ET) to sad faces [baseline and up to week 2]

    ET will measure participant attention to the screen and be used to ensure that participants are looking at the stimulus display screen during the course of the experimental paradigms. Change in Proportion of fixation (POF) to the eye region in sad faces as measured by ET.

  3. Change in Auditory Steady State Response (ASSR) [baseline and up to week 2]

    ASSR measures an electrophysiological response in the human cortex after presenting stimulation consisting of pure tones at certain frequencies. For assessment of ASSRs, subjects will sit in an acoustically shielded booth in front of a computer monitor with eyes open, while passively listening to click trains presented through Etymotic insert ER-1 earphones (Etymotic Research, Elk Grove Village, IL). Stimuli will consist of standard, unattended (nontarget) auditory click trains from a three-stimulus oddball tasks. The output is thus measured in the EEG recording which is analyzed in the frequency domain. Measures of inter-trial coherence (ITC) are used to determine neural synchrony through the ASSR task, by quantifying the degree of phase consistency across trials. ASSR Power is the magnitude of the brain's voltage response to a stimulus and the consistency across trials of the time course of this time-locked response.

Secondary Outcome Measures

  1. Change in neural processing on EEG to sad faces [baseline and up to week 2]

    The latency of the right lateralized N170, an ERP component that reflects the neural processing of faces, familiar objects, or words, to sad faces.

  2. Change in ET to different emotionally valenced faces [baseline and up to week 2]

    The amplitude and latency of the right lateralized N170 as measured from eye-fixation related potentials (EFRP) when participants are viewing different emotionally valenced faces.

  3. Change in ET to neutral faces and non-social stimuli [baseline and up to week 2]

    ET will measure participant attention to the screen and be used to ensure that participants are looking at the stimulus display screen during the course of the experimental paradigms. Change in proportion of fixation to eyes in neutral faces and non-social stimuli (i.e., houses).

  4. Change in Frith Happé Animations Task [baseline and up to week 2]

    The latency to look to the eye-region of faces relative to image onset, measured in milliseconds (ms) for sad and neutral faces and triangle pursuit duration in an anthropomorphic animated triangles test.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 40 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Individuals from Yale University and the surrounding community who are between the ages of 18 and 40 years old with or without a diagnosis of depression. Or individuals between the ages of 18 and 40 years old with a diagnosis of autism spectrum disorder, autistic disorder, PDD NOS, or Asperger syndrome with or without a diagnosis of depression.

  • A depression score on the HDRS-17 of at least 20 will be used as a cut-off for depression.

  • Participants are unmedicated or on stable medication treatment for at least two weeks.

  • Willingness and ability to participate in an EEG and eye-tracking procedure.

  • Provision of signed and dated informed consent.

Exclusion Criteria:
  • Participants reporting significant head trauma or serious brain illness.

  • Participants unable to provide signed informed consent.

  • Participants with major psychiatric illness that would preclude completion of study measures. Participants with diagnosis of a psychotic or bipolar illness with be excluded.

  • Participants with a history of serious medical illness, stroke, seizures, epileptiform EEG abnormalities, or family history of epilepsy.

  • Participants taking prescription medications that may affect cognitive processes under study.

  • Participants taking any medication that may increase their risk of seizures.

  • Participants who have taken alcohol or recreational drugs within the preceding 24 hours prior to the scheduled study visit as determined by the urine toxicology test.

  • Participants with a history of substance or alcohol abuse or dependence in the past 6 months.

  • Participants with a significant risk of suicide or a h/o suicide attempt in the last 6 months. Participants with active suicidal ideation will be excluded from the study.

  • Females of known/suspected pregnancy or who test positive on a pregnancy test.

  • Participants with a history of metalworking or injury by shrapnel or metallic objects.

  • Participants with a history of prior TMS therapy or use of an investigational drug within 12 weeks of visit

  • Participants with an IQ below 80 (as confirmed by the WASI, Wechsler Abbreviated Scale of Intelligence)

Contacts and Locations

Locations

Site City State Country Postal Code
1 Yale Psychiatric Hospital New Haven Connecticut United States 06520

Sponsors and Collaborators

  • Yale University

Investigators

  • Principal Investigator: Sherab Tsheringla, MD, Yale University

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Yale University
ClinicalTrials.gov Identifier:
NCT06142955
Other Study ID Numbers:
  • 2000035486
First Posted:
Nov 22, 2023
Last Update Posted:
Nov 22, 2023
Last Verified:
Nov 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Nov 22, 2023