MICRA-SYNK: Cardiac Synchronization and Tricuspid Regurgitation With Leadless Pacemaker

Sponsor
First People's Hospital of Hangzhou (Other)
Overall Status
Recruiting
CT.gov ID
NCT05817695
Collaborator
Second Affiliated Hospital, School of Medicine, Zhejiang University (Other)
40
1
15
2.7

Study Details

Study Description

Brief Summary

Comparison of cardiac synchronization and tricuspid regurgitation with or without leadless pacemaker pacing in different site

Condition or Disease Intervention/Treatment Phase
  • Device: Leadless pacemaker

Detailed Description

Right ventricular pacing might lead to pacing-induced cardiomyopathy by dyssynchrony and tricuspid regurgitation. Pacing at various sites had different effects on synchrony and tricuspid regurgitation. This study is to observe the effect of leadless pacemaker implantation in different regions on ventricular synchronization and tricuspid regurgitation. Ultrasound and ECG parameter indices are applied.

Study Design

Study Type:
Observational [Patient Registry]
Anticipated Enrollment :
40 participants
Observational Model:
Case-Only
Time Perspective:
Prospective
Official Title:
Effect of Different Pacing Sites on Cardiac Synchronization and Tricuspid Regurgitation After Leadless Pacemaker Implantation
Actual Study Start Date :
Mar 1, 2022
Anticipated Primary Completion Date :
May 1, 2023
Anticipated Study Completion Date :
May 31, 2023

Outcome Measures

Primary Outcome Measures

  1. The evaluation of cardiac electrical synchrony [1 month]

    the QRS duration after pacing

  2. The evaluation of cardiac mechanical synchrony [1 month]

    ①Synchronization analysis between left and right ventricles: interventricular mechanical delay (IVMD) in millisecond. ②Left ventricle synchrony analysis: septal-to-posterior wall motion delay (SPWMD) in millisecond,left pre-ejection interval(LPEI) in millisecond.

Secondary Outcome Measures

  1. Age may affect synchronization [1 month]

    Age in years

  2. BMI may affect synchronization [1 month]

    BMI in kg/m^2

  3. Blood pressure may affect synchronization [1 month]

    Systolic and diastolic blood pressure in mmHg

  4. The pacemaker sensing may affect synchronization [1 month]

    pacemaker sensing in millivolt

  5. The pacemaker lead impedance may affect synchronization [1 month]

    lead impedance in ohm

Eligibility Criteria

Criteria

Ages Eligible for Study:
N/A and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:

patients consent to LP implantation surgery

Exclusion Criteria:
  1. Patients with inferior vena cava thrombus, a cancer thrombus, an abnormal inferior vena cava;

  2. Patients with femoral vein stenosis and tortuosity failed to accommodate the pacemaker delivery system;

  3. Patients with myocardial infarction;

  4. Patients who have been implanted with devices that affect the pacemaker delivery system, such as vena cava filters or tricuspid valve mechanical valves;

  5. cannot understand or are unwilling to give informed consent.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Yi zhou XU Hangzhou Zhejiang China 310006

Sponsors and Collaborators

  • First People's Hospital of Hangzhou
  • Second Affiliated Hospital, School of Medicine, Zhejiang University

Investigators

  • Principal Investigator: Yi zhou XU, First People's Hospital of Hangzhou

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
First People's Hospital of Hangzhou
ClinicalTrials.gov Identifier:
NCT05817695
Other Study ID Numbers:
  • MICRA-SYNK-001
First Posted:
Apr 18, 2023
Last Update Posted:
Apr 18, 2023
Last Verified:
Dec 1, 2022
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by First People's Hospital of Hangzhou
Additional relevant MeSH terms:

Study Results

No Results Posted as of Apr 18, 2023