Clinical Feasibility of Brain Radiotherapy Using Synthetic CTs in an MRI-only Workflow

Sponsor
University of Erlangen-Nürnberg Medical School (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT06106997
Collaborator
(none)
54
1
1
19
2.8

Study Details

Study Description

Brief Summary

The goal of this observational study is to show the feasibility of an MRI-only workflow in brain radiotherapy. The main question it aims to answer is:

  • Is an MRI-only workflow based on deep learning sCTs feasible in clinical routine? Participants will be treated as in clinical routine, but treatment planning will be based on sCTs, that are generated from MRI images. The dosimetrical equivalence to the standard CT based workflow will be tested at several points in the study.
Condition or Disease Intervention/Treatment Phase
  • Radiation: brain radiotherapy
N/A

Detailed Description

The purpose of this clinical study is to investigate the clinical feasibility of a deep learning-based MRI-only workflow for brain radiotherapy, that eliminates the registration uncertainty through calculation of a synthetic CT (sCT) from MRI data.

A total of 54 patients with an indication for radiation treatment of the brain and stereotactic mask immobilization will be recruited. All study patients will receive standard therapy and imaging including both CT and MRI. All patients will receive dedicated RT-MRI scans in treatment position. An sCT will be reconstructed from an acquired MRI DIXON-sequence using a commercially available deep learning solution on which subsequent radiotherapy planning will be performed. Through multiple quality assurance (QA) measures and reviews during the course of the study, the feasibility of an MRI-only workflow and comparative parameters between sCT and standard CT workflow will be investigated holistically. These QA measures include feasibility and quality of image guidance (IGRT) at the linear accelerator using sCT derived digitally reconstructed radiographs in addition to potential dosimetric deviations between the CT and sCT plan. The aim of this clinical study is to establish a brain MRI-only workflow as well as to identify risks and QA mechanisms to ensure a safe integration of deep learning-based sCT into radiotherapy planning and delivery.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
54 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Other
Official Title:
Feasibility Study of an MRI-only Workflow: Use of Synthetic CTs Generated From MRI Data for MRI-based Radiotherapy
Anticipated Study Start Date :
Jan 1, 2024
Anticipated Primary Completion Date :
Dec 1, 2024
Anticipated Study Completion Date :
Aug 1, 2025

Arms and Interventions

Arm Intervention/Treatment
Other: sCT workflow

sCT workflow

Radiation: brain radiotherapy
brain radiotherapy planned on synthetic CTs

Outcome Measures

Primary Outcome Measures

  1. Proportion of patients that can successfully be treated in an MRI-only workflow [12 month]

    All criteria have to be met for the MRI-only workflow to be classified as successful: Verification criteria that will be assessed: Can the sCT be generated and is the sCT clinically utilizable? Are the three rotations needed for CT-MRI registration each ≤ 3°? Can a treatment plan be generated and verified using the sCT? Is the dosimetric difference between sCT and CT based treatment plan in the planning target volume ≤ 3%? Is the dosimetric difference between the sCT and CT based treatment plan in affected organs at risk (receiving > 10% of prescribed dose) ≤ 3%? Are the couch correction parameters during patient positioning in the rotational degrees of freedom ≤ 3°?

Secondary Outcome Measures

  1. Reasons that lead to unfeasibility of an MRI-only workflow [12 month]

    Presence (Yes/No) of individual reasons responsible for the unfeasibility of the MRI-only workflow, as assessed with a predefined checklist.

  2. Dosimetric differences between MRI-only and standard workflow for radiotherapy treatment planning [12 month]

    Paired difference in Dose-volume-histogram parameters (Target coverage, mean, median, near maximum and minimum dose) between MRI-only and standard radiotherapy treatment workflow.

  3. Measurement of intra-MRI patient positional changes [12 month]

    Patient shift (vector magnitude) and rotational errors occuring during the course of MRI acquisition due to patient movement, as assessed by rigid registration of the last acquired MRI sequence in reference to the first sequence.

  4. Organ at risk contouring accuracy on MRI data [12 month]

    Similarity of organ at risk segmentations defined in MRI compared to reference segmentations defined in CT as assessed by the volumetric and surface Dice score, as well as mean surface and Hausdorff distances.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Written informed consent

  • Patient older than 18 years

  • Tumor or metastases in the brain

  • Immobilization with stereotactic mask

  • Treatment on stereotactic linear accelerator (2.5 mm leafs) equipped with 2D/2D X-ray system

Exclusion Criteria:
  • Metal in the body, metal implants, pacemakers or other patient-specific factors that are a contraindication to an MRI scan

  • Metal implants, pacemakers or other patient-specific factors associated with increased risk from an MRI scan

  • Renal insufficiency (eGFR < 60 ml/min), allergy or other patient-specific factors that constitute a contraindication to contrast administration

  • Renal insufficiency (eGFR < 60 ml/min), allergy or other patient-specific factors associated with an increased risk from contrast administration

  • Patients who are institutionalized in care facilities, prisons or other supervised facilities.

  • Patients under guardianship

  • Non-consenting patients

  • Pregnant or breastfeeding patients

Contacts and Locations

Locations

Site City State Country Postal Code
1 Erlangen, Universitätsklinikum Strahlenklinik Erlangen Germany 91054

Sponsors and Collaborators

  • University of Erlangen-Nürnberg Medical School

Investigators

  • Principal Investigator: Christoph Bert, Prof. Dr. rer. nat, Universitätsklinikum Erlangen, Strahlenklinik
  • Principal Investigator: Florian Putz, PD Dr. med., Universitätsklinikum Erlangen, Strahlenklinik

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
University of Erlangen-Nürnberg Medical School
ClinicalTrials.gov Identifier:
NCT06106997
Other Study ID Numbers:
  • sCT-Feasibility
First Posted:
Oct 30, 2023
Last Update Posted:
Oct 30, 2023
Last Verified:
Oct 1, 2023
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Oct 30, 2023