BVS-OCT Imaging Study

Sponsor
Icahn School of Medicine at Mount Sinai (Other)
Overall Status
Completed
CT.gov ID
NCT03194711
Collaborator
(none)
40
1
10.6
3.8

Study Details

Study Description

Brief Summary

The single center retrospective study evaluates the acute and long term outcomes of bioabsorbable drug-eluting scaffolds (BVS) implantation in 50 consecutive coronary artery disease (CAD) patients using optical coherence tomography (OCT) imaging.

Condition or Disease Intervention/Treatment Phase
  • Device: BVS implantation

Detailed Description

  1. INTRODUCTION Bioabsorbable drug-eluting scaffolds ("BVS") have emerged as a potential major breakthrough for treatment of coronary artery lesions providing a possibility to overcome the long term limitations of conventional stent implantation which precludes future surgical revascularization, eliminates reactive vasomotion, impairs noninvasive imaging and exposes patients to the risk of very late stent thrombosis. BVS have been extensively studied in clinical trials. Treatment of noncomplex obstructive coronary artery disease with BVS was within the prespecified margin for noninferiority compared to Xience stent with respect to target lesion failure at 1 year in the latest large-scale randomized trial (ABRORB III). Although the concept of self-degrading stent is attractive and the results from clinical trials have been promising, there is a paucity of data regarding the use of BVS in "real world" patients undergoing percutaneous intervention ("PCI"). The outcomes from a large BVS registry of patients with relatively unselected clinical characteristics and lesions were comparable to those reported for the second generation drug eluting stents ("DES"), however, the scaffold thrombosis rate in the first 30 days after implantation resembled that of the first generation DES suggesting that the lesion selection and procedure optimization require further improvement. BVS development has required new imaging modalities, assessment methodologies, and treatment strategies because their design, degradation rate, coating, changes in mechanical properties may affect safety and efficacy of the device. Due to its high resolution, Optical Coherence Tomography ("OCT") imaging has played a central role in understanding the short and long term performance of bioresorbable scaffolds.

  2. STUDY AIM To evaluate the acute and long term outcomes of BVS implantation in consecutive coronary artery disease ("CAD") patients using OCT imaging.

  3. STUDY POPULATION Fifty (50) consecutive patients who underwent PCI with BVS implantation and OCT imaging for treatment of CAD.

  4. STUDY DESIGN This is a single center retrospective analysis of data collected under the EXEMPT database (GCO# 02-0178) at the Cardiac Catheterization Laboratory at Mt. Sinai Hospital.

  5. STUDY PROCEDURES Patients with stable CAD who underwent PCI with BVS implantation. Lesions were treated with pre-dilatation using conventional semicompliant or non-compliant balloon. The use of additional devices, cutting balloons or rotablator, were performed at the operator's discretion. The operator made the decision on BVS length and size. First OCT pullback (OCT-PRE) was performed before BVS implantation to analyze lesion stenosis, references, and plaque morphology including the extent and location of calcification. In addition, online co-registration of OCT with coronary angiogram was performed to confirm the correct spatial orientation of OCT findings. The second OCT pullback (OCT - POST) was performed after BVS implantation followed by post-dilatation (20 atm). Angio-OCT co-registration was used to assess acute post-procedural results.

  6. STUDY OUTCOMES

  • Acute lumen gain after BVS implantation by quantitative coronary angiography ("QCA") and OCT; effect of coronary calcification on lumen gain, BVS apposition and expansion.

  • Review of the clinical follow up data which was collected at 1 month and 12 months after the procedure

  1. IMAGE ANALYSIS

QCA analysis. In each patient, the treated segment (in-scaffold) and the peri-scaffold segment (defined as 5 mm proximal and distal to the scaffold edge) will be analyzed by QCA in paired matched angiographic views before and after procedure using metallic markers at the proximal and distal ends of the device. Minimal lumen diameter (MLD), reference vessel diameter, percentage of area stenosis, and lesion length will be measured by two experienced analysts using dedicated software (QCA-QAngioXA 7.3; Medis) as previously described. Acute lumenal gain will be defined as the difference between MLD immediately after procedure and MLD before BVS implantation. In addition, the presence of angiographic calcification will be assessed. Calcification will be identified by angiography as readily apparent radiopacities within the vascular wall at the site of stenosis and will be classified as none/mild or moderate (radiopacities noted only during the cardiac cycle before contrast injection)/severe (radiopacities visible without cardiac motion before contrast injection usually compromising both sides of the lumen).

OCT lesion analysis will be performed offline at 1-mm interval according to previously validated criteria and as we previously described. The minimal and reference lumen diameter and area will be measured to calculate percent lumen area stenosis. Plaques will be classified as fibrous, lipid, or calcified. For each lipid plaque, the maximal lipid arc will be measured at 1-mm interval and the minimal thickness of the fibrous cap will be assessed. The degree of circumferential extent of calcification will be quantified at 1 mm interval by measuring the maximal calcification arc.

OCT analysis of BVS will be performed at 1-mm interval within the entire stented segment and at 5 mm proximal and distal to the BVS edge. For each cross section analyzed, the area, mean, minimal and maximal diameters of the BVS will be measured automatically with manual corrections if appropriate. The proximal and distal reference vessel area (RVA) will be calculated as the mean of the largest two lumenal areas 5 mm distal and proximal to the BVS edge. Acute strut fracture will be suspected if isolated struts are detected lying unopposed in the lumen with no connection to other surrounding stent struts. 3D OCT reconstruction with QAngio OCT RE software (Medis) will be performed to confirm the diagnosis. Incomplete strut apposition (ISA) will be defined as the presence of struts separated from the underlying vessel wall. The percentage of ISA will be calculated as a ratio of malapposed struts number to the total number of struts observed at 1-mm interval. Since abluminal border of the struts can be visualized in BVS, we will assess the ISA area for each frame with malapposed struts. The percentage of Residual Area Stenosis (RAS) will be calculated as: [(1 - (minimal lumen area/RVA))] ×50 ; the eccentricity index as the ratio between the minimal and the maximal diameter. The symmetry index will be defined as (maximal stent diameter - minimal stent diameter)/(maximal stent diameter). OCT analysis will be performed in Mount Sinai Cath Lab Core imaging laboratory.

  1. PROPENSITY-MATCHED COMPARISON BETWEEN BVS AND DES A retrospective analysis will be performed on 50 study patients who underwent PCI with BVS and consecutive patients who underwent DES implantation in Mount Sinai catheterization laboratory with the comparator sample size of 50. The DES patients will be selected from the Mount Sinai imaging database. Propensity score matching will be performed to reduce the effect of confounding factors in the retrospective study for two groups of patients with different recruitment periods.
Multiple logistic regression analysis will include the following variables as covariates:

previous MI, previous CABG, CAD family history, history of smoking, dyslipidemia, diabetes mellitus, use of atherectomy device, stent/BVS post-dilatation, stent/BVS diameter and length, maximal calcium arc by OCT and total number of treated vessels.

Study Design

Study Type:
Observational
Actual Enrollment :
40 participants
Observational Model:
Case-Only
Time Perspective:
Retrospective
Official Title:
Bioabsorbable Drug-eluting Scaffolds (BVS)-Optical Coherence Tomography (OCT) Imaging Study
Actual Study Start Date :
May 30, 2017
Actual Primary Completion Date :
Apr 17, 2018
Actual Study Completion Date :
Apr 17, 2018

Arms and Interventions

Arm Intervention/Treatment
Patients with stable CAD

Device: BVS implantation
BVS implantation using conventional semicompliant or non-compliant balloon

Outcome Measures

Primary Outcome Measures

  1. Acute lumen gain by quantitative coronary angiography (QCA) [1 year]

    Acute lumen gain after BVS implantation by quantitative coronary angiography (QCA)

  2. Acute lumen gain by Optical Coherence Tomography (OCT) [1 year]

    Acute lumen gain after BVS implantation by OCT

Secondary Outcome Measures

  1. Major adverse cardiac events [1 year]

    Major adverse cardiac events, defined as a composite of cardiac death, myocardial infarction, and target lesion

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Consecutive patients who underwent PCI with BVS implantation and OCT imaging for treatment of CAD
Exclusion Criteria:
  • None

Contacts and Locations

Locations

Site City State Country Postal Code
1 Icahn School of Medicine at Mount Sinai New York New York United States 10029

Sponsors and Collaborators

  • Icahn School of Medicine at Mount Sinai

Investigators

  • Principal Investigator: Annapoorna Kini, MD, MRCP, FACC, Icahn School of Medicine at Mount Sinai

Study Documents (Full-Text)

None provided.

More Information

Publications

Responsible Party:
Icahn School of Medicine at Mount Sinai
ClinicalTrials.gov Identifier:
NCT03194711
Other Study ID Numbers:
  • GCO 16-2757
First Posted:
Jun 21, 2017
Last Update Posted:
May 7, 2018
Last Verified:
May 1, 2018
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Icahn School of Medicine at Mount Sinai
Additional relevant MeSH terms:

Study Results

No Results Posted as of May 7, 2018