European Resuscitation Council (ERC) Guidelines for Resuscitation 2010 emphasize high quality chest compressions .They propose minor changes for pregnant women: manual left deviation of the uterus or a left-lateral incline of 15-30to alleviate pressure on the inferior vena cava. We will examine the performance of the Glidescope (GVL), the Pentax-AWS Airwayscope(AWS) and Macintosh laryngoscope (McL) for airway management during chest compressions on 15 and 30 degree left-lateral tilt (15 &30 LLT) custom-made hard wedges.
Condition or Disease | Intervention/Treatment | Phase |
---|---|---|
|
N/A |
Detailed Description
Materials
-
Sim Mom manikin (Laerdal, Stavanger, Norway)
-
Stryker ST104-747(Transport stretcher®, 760 x 2110 mm, 228 kg, Stryker Co., Kalamazoo, Michigan, US)
-
LUCAS Chest Compression System( LUCAS Chest Compression System, Physio-Control/Jolife AB)
-
Backboard(450 ×600 ×10 mm, 3 kg Lifeline Plastic, Sung Shim Medical Co., Bucheon, Korea)
Study Design
Arms and Interventions
Arm | Intervention/Treatment |
---|---|
Experimental: Direct laryngoscope Macintosh laryngoscope |
Device: 15 degree left-lateral tilt wedges
The wedges are made of aluminium
Other Names:
Device: 30 degree left-lateral tilt wedges
The wedges are made of aluminium
Other Names:
|
Experimental: Videolaryngoscope-1 Glidescope |
Device: 15 degree left-lateral tilt wedges
The wedges are made of aluminium
Other Names:
Device: 30 degree left-lateral tilt wedges
The wedges are made of aluminium
Other Names:
|
Experimental: Videolaryngoscope-2 Airwayscope |
Device: 15 degree left-lateral tilt wedges
The wedges are made of aluminium
Other Names:
Device: 30 degree left-lateral tilt wedges
The wedges are made of aluminium
Other Names:
|
Outcome Measures
Primary Outcome Measures
- Time to intubation [1day]
We will check the times from inserting blade to mouth to exposing vocal cord and from exposing vocal cord to first ambu-bagging.
- Success rate of intubation [1day]
Definition of failed intubation Time to intubation is longer than 90 seconds. Wrong placement of endotracheal tube (For example : Esophageal intubation etc.)
Secondary Outcome Measures
- Laryngeal View during intubation [1day]
We will record the best laryngeal View during intubation. We will record according to the Cormack-Lehane Grade system.
- The preference for laryngoscopes [1day]
The preference for laryngoscope regardless of tilting degree of wedges The preference for laryngoscope in 15 degree left-lateral tilt situation . The preference for laryngoscope in 30 degree left-lateral tilt situation . (Participants will select only 1 of 3 laryngoscopes and the preference will be displayed as histogram)
Eligibility Criteria
Criteria
Inclusion Criteria:
-
Experience of intubation > 50 times
-
Postgraduates year 1,2,3,4 and Emergency physicians in emergency department
Exclusion Criteria:
- Wrist or Low back disease
Contacts and Locations
Locations
Site | City | State | Country | Postal Code | |
---|---|---|---|---|---|
1 | Hanyang University Seoul Hospital | Seoul | Korea, Republic of | 133792 |
Sponsors and Collaborators
- Hanyang University Seoul Hospital
Investigators
- Principal Investigator: Sang hyun Lee, M.D, Hanyang University Seoul Hospital
Study Documents (Full-Text)
None provided.More Information
Publications
None provided.- HYI-14-004-1