zLAP: Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study

Sponsor
Abbott Medical Devices (Industry)
Overall Status
Completed
CT.gov ID
NCT00632372
Collaborator
(none)
8
10
95
0.8
0

Study Details

Study Description

Brief Summary

The purpose of this study is to collect and analyze electrical measurements, timing, and signals from a CRT-D device in heart failure patients who either already have an implanted left atrial pressure sensor or will undergo a simultaneous implantation of a left atrial pressure sensor and a CRT-D device. These devices may be placed at the same time or separately (staged procedure) at the discretion of the investigator. A comparison will be made between the information gathered from the CRT-D system and the information gathered by the left atrial pressure sensor.

Condition or Disease Intervention/Treatment Phase
  • Device: Cardiac Resynchronization Therapy
  • Device: HeartPOD™ System

Detailed Description

This is a multi-center feasibility study.

.

Study Design

Study Type:
Observational
Actual Enrollment :
8 participants
Observational Model:
Case-Only
Time Perspective:
Prospective
Official Title:
CRT-D Based Heart Failure Monitoring Study
Study Start Date :
Jan 1, 2008
Actual Primary Completion Date :
Sep 1, 2011
Actual Study Completion Date :
Dec 1, 2015

Arms and Interventions

Arm Intervention/Treatment
HeartPOD™ System with Cardiac Resynchronization Therapy

All patients will receive both a HeartPod device and a CRT-D device.

Device: Cardiac Resynchronization Therapy
Pacing of the left ventricle to resynchronize ventricular contraction.
Other Names:
  • CRT-D
  • Device: HeartPOD™ System
    Left atrial pressure monitoring.

    Outcome Measures

    Primary Outcome Measures

    1. Determine which heart failure monitoring feature acquired by the CRT device correlates most closely with simultaneously measured left ventricular filling pressure, as measured by left atrial pressure. [12 months]

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 85 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Age > 18 and ≤ 85.

    • Have an approved indication per ACC/AHA/HRS guidelines for implantation of a CRT-D. Alternatively, the patient may already have in place an existing Promote CRT-D or other SJM CRT device with similar functions, or have a CRT-D device that requires a generator change. In addition, the patient may be already enrolled in HOMEOSTASIS I or II and completed the 12-month follow-up.

    • Central venous vascular access.

    • Have a legally marketed right atrial bipolar pacing lead, a right ventricular bipolar defibrillation lead, and a left ventricular bipolar pacing lead.

    • Demonstrate capability of Valsalva maneuver with airway pressure > 40 mm Hg for ≥10 seconds.

    • The subject and the treating physician agree that the subject is geographically stable and willing to comply with all required post-procedure follow-up, and that the patient is capable of correct device use as outlined in the protocol.

    • The subject has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board or Ethics Committee of the respective clinical site

    Exclusion Criteria:
    • Intractable HF with resting symptoms despite maximal medical therapy (AHA/ACC Stage D) or active listing for cardiac transplantation (<6 months survival expected).

    • Resting systolic blood pressure < 90 or > 180 mm Hg.

    • Acute Myocardial Infarction (MI), unstable ischemic syndrome within the last 6 weeks.

    • Percutaneous coronary intervention (PCI) or cardiac surgery performed or planned within ± 6 weeks.

    • Coexisting stenotic valve lesions, vegetations, hypertrophic cardiomyopathy, amyloidosis or other infiltrative heart disease, constrictive, restrictive disease, tamponade, or moderate or large pericardial effusion.

    • Subject has a history of deep venous thrombosis or pulmonary embolism within the last 6 months.

    • Surgical correction of congenital heart disease involving atrial septum that will prevent safe implantation of the SJM HeartPOD ISL.

    • Cerebral Vascular Accident (CVA) or Transient Ischemic Attacks (TIA's) within the last 6 months. History of uncorrected cerebral vascular disease.

    • Atrial or ventricular thrombus, tumor or systemic thromboembolism.

    • Atrial septal defect or clinically significant patent foramen ovale.

    • Life expectancy less than one year from malignancy, primary pulmonary hypertension, renal, hepatic, or neurological condition, etc.

    • Gastrointestinal bleeding during the last 6 months.

    • Coagulopathy or uninterruptible anticoagulation therapy or unable to take antiplatelet medications.

    • Creatinine > 2.4 gm/dl (212 µmol/L) at enrollment.

    • Active systemic infection.

    • The subject is currently participating in an investigational drug or another device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints.

    • Have a contraindication for an emergency thoracotomy

    • Have a hypersensitivity to a single 1.0mg dose of dexamethasone sodium phosphate or short term contact with heparin.

    • Positive pregnancy test at enrollment or planning a pregnancy in the next 12 months.

    • Patient is pacemaker dependent, where cessation of pacemaker function consistently results in syncope or ventricular asystole.

    • Incompatible previously implanted intracardiac devices.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 University of Southern California Los Angeles California United States 90033
    2 Cedars-Sinai Medical Center Los Angeles California United States 90048
    3 Massachusetts General Hospital Boston Massachusetts United States 02114
    4 University of Rochester Medical Center Rochester New York United States 14642
    5 Sanger Clinic Charlotte North Carolina United States 28203
    6 The Cleveland Clinic Foundation Cleveland Ohio United States 44195
    7 Ohio State University Columbus Ohio United States 43210
    8 Oklahoma Heart Hospital Oklahoma City Oklahoma United States 73120
    9 Medical Univserity of South Carolina Charleston South Carolina United States 29403
    10 Christchurch Hospital Christchurch New Zealand

    Sponsors and Collaborators

    • Abbott Medical Devices

    Investigators

    • Principal Investigator: Richard Troughton, MD, Christchurch Hospital - Christchurch, New Zealand

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Abbott Medical Devices
    ClinicalTrials.gov Identifier:
    NCT00632372
    Other Study ID Numbers:
    • 60015786
    First Posted:
    Mar 10, 2008
    Last Update Posted:
    Oct 12, 2020
    Last Verified:
    Oct 1, 2020
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Studies a U.S. FDA-regulated Device Product:
    Yes
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Oct 12, 2020