Clinical Investigation of the Safety and Performance of HiResTM Ultra Cl HiFocusTM SlimJ Electrode (Cl-1600-05) and HiResTM Ultra 3D Cl HiFocusTM SlimJ Electrode (Cl-1601-05) (Ultra X) in Adults With Severe-to-profound Hearing Loss

Sponsor
Advanced Bionics AG (Industry)
Overall Status
Recruiting
CT.gov ID
NCT04929470
Collaborator
(none)
30
2
6.9
15
2.2

Study Details

Study Description

Brief Summary

This is a prospective study designed to evaluate the safety and performance of the HiResTM Ultra Cl HiFocusTM SlimJ Electrode and HiResTM Ultra 3D Cl HiFocusTM SlimJ Electrode (Ultra

  1. under normal conditions of use as it is approved for this device. Participants receive interventions as part of routine medical care.
Condition or Disease Intervention/Treatment Phase
  • Device: cochlear implantation

Detailed Description

This study is set up to document any adverse events and comparing pre- to post-implant benefit to subjects. Any adverse events associated with the device will be documented via Advanced Bionics complaint handling system for the lifetime of the device. A within-subjects repeated-measures design will be employed. Speech perception will be evaluated preoperatively with conventional amplification to determine candidacy and to establish baseline performance. Efficacy parameters are speech perception data which will be collected according to clinical routine with a 6 month follow up period. Subjects will be implanted unilaterally with the Ultra X according to standard clinical care.

The primary efficacy objective is to demonstrate that mean monosyllabic word recognition score with the Ultra X used in combination with a sound processor programmed with the latest fitting software six months after activation is at least 20% better than the mean word score at baseline with conventional amplification in the same ear.

The primary efficacy endpoint is reached six months after device activation.

Study Design

Study Type:
Observational
Anticipated Enrollment :
30 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Clinical Investigation of the Safety and Performance of HiResTM Ultra Cl HiFocusTM SlimJ Electrode (Cl-1600-05) and HiResTM Ultra 3D Cl HiFocusTM SlimJ Electrode (Cl-1601-05) (Ultra X) in Adults With Severe-to-profound Hearing Loss
Actual Study Start Date :
Jul 6, 2021
Anticipated Primary Completion Date :
Jan 31, 2022
Anticipated Study Completion Date :
Jan 31, 2022

Outcome Measures

Primary Outcome Measures

  1. Speech recognition score (word score) [6 months]

    The primary efficacy objective is to demonstrate that mean monosyllabic word recognition score (Minimum Score 0 percent and maximum score 100 percent wheras 0 percent is worse and 100 is better) with the Ultra implants used in combination with a sound processor programmed with the latest fitting software is at least 20 percent better than the mean monosyllabic word score at baseline with conventional amplification in the same ear.

  2. Analysis of participants with device failure [6 months]

    A maximum of one device failure that require device replacement during the first six months following device activation (activation approximately one to eight weeks after surgery).

Secondary Outcome Measures

  1. Analysis of Speech reception threshold [6 months]

    50 percent speech reception threshold in the Oldenburger Sentence Test (OlSa) in noise in the implanted ear six months after device activation compared to baseline performance with conventional amplification in the same ear.

Other Outcome Measures

  1. Device fitting data [6 months]

    M-level [CU] CU=Clinical Units

  2. Device verification data [6 months]

    Impedances [Kilo Ohm]

  3. Professional feedback from the audiologist using the latest fitting software to program the latest processor [6 months]

    Feedback will be collected with a structured questionnaire

  4. Feedback from the surgeon on handling of the device and tools during implantation [6 months]

    Feedback will be collected with a structured questionnaire

  5. hours of usage [6 months]

    hours of usage as summarized in the logging of the processor

  6. using habits of participants [6 months]

    Assessement with a structured patient questionnaire

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Inclusion Criteria:
  • No previous experience with any auditory implant

  • 18 years of age or older

  • Postlingual onset of severe hearing loss (≥ 4 years of age)

  • Limited benefit from appropriately fitted hearing aids, defined as scoring 60% or less in Freiburger Monosyllabic word test

  • German language proficiency

  • Willingness to participate in all scheduled procedures outlined in the protocol

Exclusion Criteria:
  • Cochlear malformation or obstruction that would preclude full insertion of electrode array.

  • Presence of additional disabilities that would prevent or interfere with participation in the required study procedures

  • Medical or psychological conditions that contraindicate surgery or impact the ability to manage an implanted device or the study related procedures

  • Evidence of central auditory lesion or compromised auditory nerve

  • Pregnancy at time of surgery.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Unfallkrankenhaus Berlin (UKB Berlin Germany 12683
2 HNO-Klinik Düsseldorf Düsseldorf Germany 40225

Sponsors and Collaborators

  • Advanced Bionics AG

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Advanced Bionics AG
ClinicalTrials.gov Identifier:
NCT04929470
Other Study ID Numbers:
  • ABIntl-19-45
First Posted:
Jun 18, 2021
Last Update Posted:
Nov 29, 2021
Last Verified:
Nov 1, 2021
Individual Participant Data (IPD) Sharing Statement:
Undecided
Plan to Share IPD:
Undecided
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Additional relevant MeSH terms:

Study Results

No Results Posted as of Nov 29, 2021