Phase II Study of the Role of Anti-CEA Antibody Immunoscintigraphy & Positron Emission Tomography in the Localization of Recurrent Colorectal Carcinoma in Patients With Rising Serum CEA Levels in the Absence of Imageable Disease by Conventional Modalities

Sponsor
National Cancer Institute (NCI) (NIH)
Overall Status
Completed
CT.gov ID
NCT00001568
Collaborator
(none)
200
1
67.9
2.9

Study Details

Study Description

Brief Summary

Positron Emission Tomography (PET scanning) is performed using a total dose of less than 50 mRad per patient visit. Fludeoxyglucose F 18 (FDG) is injected intravenously over 2 min. Initial dynamic images will be obtained over the heart. Emission imaging will work from the midcervical region down to the perineal region.

For CEA scanning, radiolabeled antibody, arcitumomab (IMMU-4), is injected intravenously over 5 min. A single photon emission computed tomography (SPECT) transmission scan is performed over the same regions as the emission scans. Total dose from transmission scans should be no more than 20 mRad per patient visit.

Patients then undergo exploratory laparotomy performed by two surgeons, one blinded to the results of the CEA-Scan and PET scan.

At the completion of all exploration, all identified disease is biopsied for pathologic analysis and any resectable disease is removed.

Patients are followed every 3 months for 1 year, every 6 months for the second year, and then after 3 years.

Condition or Disease Intervention/Treatment Phase
Phase 2

Detailed Description

Recurrences following resection for colorectal carcinoma occur in 50% of patients. Early detection and management of recurrences results in improved survival. Post-operative surveillance consists of serial CT scans, chest x-rays, colonoscopy and CEA determinations. Elevations in the serum CEA level can be the earliest and most sensitive indicator of recurrence. A rise in the serum CEA level in the absence of imageable disease presents a particular diagnostic challenge. Advanced imaging modalities such as Positron Emission Tomography (PET) and anti-CEA antibody immunoscintigraphy have been proposed as a way of localizing disease in these patients. This study will evaluate the sensitivity, specificity, accuracy and predictive value of FDG-PET scans and anti-CEA immunoscintigraphy in patients following resection of colorectal carcinoma who have rising serum CEA values in the absence of imageable disease by conventional modalities. Patients who meet inclusion criteria will undergo FDG-PET scan and anti-CEA immunoscintigraphy followed by an exploratory laparotomy. Abdominal explorations will be conducted by two surgeons, one of whom will be blinded to the results of the FDG-PET and CEA scans. All suspicious lesions will be biopsied and if possible resected. Results at operation will be correlated with the results of the scans. The goal of the study is to determine the role of FDG-PET scanning and anti-CEA immunoscintigraphy in the localization of recurrent colorectal carcinoma in patients with rising serum CEA levels.

Study Design

Study Type:
Interventional
Primary Purpose:
Treatment
Official Title:
Phase II Study of the Role of Anti-CEA Antibody Immunoscintigraphy & Positron Emission Tomography in the Localization of Recurrent Colorectal Carcinoma in Patients With Rising Serum CEA Levels in the Absence of Imageable Disease by Conventional Modalities
Study Start Date :
Feb 1, 1997
Study Completion Date :
Oct 1, 2002

Outcome Measures

Primary Outcome Measures

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    N/A and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No

    All patients greater than 18 years old who have had a prior resection of colorectal cancer and are suspected of having recurrent disease.

    Rising serum CEA levels greater than 6 on two successive tests.

    Resectable residual or recurrent disease. Patients in the occult arm (Arm 1) must have no visible residual disease in the abdomen at the time of the last surgical exploration. In addition, there must be no imageable definitive site of recurrent disease using conventional imaging modalities including; CT scan of chest/ abdomen/ pelvis with contrast, MRI scan, and chest x-ray. Patients in arm 2 may have a single site of recurrent or metastatic disease which is resectable but in whom additional sites of disease are not known and no imageable disease other than a solitary site of potentially resectable disease is identified.

    Patients must have an ECOG performance status of 0-1.

    Patients must be willing to return to NIH for follow-up.

    Patients must be able to provide informed consent as demonstrated by the signed consent.

    Patients must be 2 or more months from abdominal or thoracic surgery.

    No patients with medical contraindication to abdominal exploration.

    No patients with recurrent disease detected by conventional imaging studies as outlined above. Metastatic disease localized outside of the abdominal cavity by conventional imaging studies as outlined above. Patients must weigh less than 136 kgs. which is the weight limit for the scanner tables.

    No patients with previous injection of murine monoclonal antibodies: Human anti-mouse assay (HAMA) will be performed in patients with prior history of receiving murine monoclonal antibodies.

    No patients that are pregnant or breast feeding.

    Patients who are HIV + will be excluded.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 National Cancer Institute (NCI) Bethesda Maryland United States 20892

    Sponsors and Collaborators

    • National Cancer Institute (NCI)

    Investigators

    None specified.

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    Responsible Party:
    , ,
    ClinicalTrials.gov Identifier:
    NCT00001568
    Other Study ID Numbers:
    • 970068
    • 97-C-0068
    First Posted:
    Nov 4, 1999
    Last Update Posted:
    Mar 4, 2008
    Last Verified:
    Oct 1, 2002
    Keywords provided by , ,
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Mar 4, 2008