Comparison Between the Subglotic Diameter and the Epiphyseal Diameter of the Radius in Children for Prediction of Appropriate Endotracheal Tube Sizes

Sponsor
Mansoura University (Other)
Overall Status
Unknown status
CT.gov ID
NCT03713385
Collaborator
(none)
147
1
10
14.7

Study Details

Study Description

Brief Summary

Background: In pediatric anesthesia, selection of the appropriate endotracheal tube (ETT) size is an important task because the inappropriate one may lead to much complication. The aim of this study is to compare between the subglotic diameter and the epiphysis diameter of radius measured by ultrasonography for prediction of optimum endotracheal tube size in children.

Methods: Patients aged from 1 to 6 years will be scheduled for elective surgery under general anesthesia and intubation, were enrolled in this study. Patients were randomly divided into three groups according to method of choosing the tube size.

Aged group (n =49): determined the optimal endotracheal tube size according to age of the child (internal diameter [ID] in mm = [age in years + 16] /4) suggested by Cole.4 Subglottic diameter group (n =49): The subglottic transverse diameter was estimated with ultrasonography on the middle of the anterior region of the neck at the level of cricoid cartilage.

Epiphyseal diameter group (n =49): the epiphyseal transverse diameter of the distal radius was estimated with ultrasonography.

Patient descriptive data, size of the selected ETT, number and size of the optimum tube, number of re-intubation due to incorrect size of ETT either smaller or larger were recorded. Subglottic transverse diameter (mm) and time of intubation were measured. After intubation, pulse, respiratory rate, arterial blood saturation, capnograghy and airway pressure were recorded during surgery.

Any airway complications after extubation as edema, stenosis or stridor were also recorded.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    Introduction:

    In pediatric anesthesia, selection of the appropriate endotracheal tube (ETT) size is an important task because the inappropriate one may lead to much complication. Oversized tubes cause airway edema, post- extubation stridor, subglottic stenosis, or cartilaginous ischemia, smaller ones increase the resistance to gas flow and risk of aspiration, insufficient ventilation, and poor monitoring of end tidal gases.Therefore, many methods have been suggested recently to precisely predict the optimal size of ETT in children to avoid any harmful complication.

    Most of the anesthesiologists choose the appropriate ETT size by using calculating formulae which are based on the children's descriptive data such as weight, height or age. The Cole's equation (internal diameter [ID] in mm = [age in years + 16] / 4) is still considered as one of the prevalent methods in spite of its poor prediction power.

    Bone and cartilage growth of the body are supposed to be related to each other, therefore some measurements of body growth as bony cartilage growth of the hand are worthy of attention as a marker of tracheal diameter specially bone measurements for the hand is generally accepted as the indicator of growth.

    Also, the transverse diameter or width of the child's fifth fingernail has been used to select the size of ETT. However, a few reports have stated that it is unreliable method to predict the correct tube.

    The epiphyseal transverse diameter of the distal radius measured by ultrasonography is a good predictor of the appropriate ETT size. This formula can be rephrased in a tidy way as follows: ETT (mm) = (29.5 + EpiRad [mm])/8.

    The ultrasonography could be a reliable, safe, and non-invasive modality for evaluation of the upper airway at the level of subglottic region which considered the narrowest diameter of upper airway and may be helpful to estimate the proper size endotracheal tube. Ultrasound offers a number of advantages compared to other competitive imaging modalities.

    Our proposal:

    Is to find the best, easier way and most safe method to select the optimum ETT size for children.

    Aim of the work:

    To compare between the subglotic diameter and the epiphysis diameter of radius measured by ultrasonography for prediction of optimum endotracheal tube size in children.

    Research Gap:

    To our knowledge, it is the first study conducted in Egypt to evaluate the value of ultrasonography in selecting the appropriate endotracheal tube size in children.

    Hypothesis:

    Selecting the ideal endotracheal tube size is a challenging issue needing more appropriate method for selection. Up till now, no ideal method is present and most physicians depend upon roughly calculated formulas for choosing the size. These methods depend mainly upon patients' age. Here, we used ultrasonography as a simple and accurate method.

    Patient & Methods:

    This study will be done at Mansoura University Children's Hospital over a three month duration starting from October 2018 till January 2019. Informed consents will be obtained from patients' guardians or parents and the participant data will be kept confidential. All participants are free not to participate in the research at any time without penalty.

    Sample size:

    Sample size was calculated using Medcalc 15.8 (https://www.medcalc.org/). The primary outcome of interest is the incidence of appropriate tube selection. Previous studies found that the incidence of appropriate tube selections were 74.7% using subglottic US, 45.3% for Cole's formula and 90% for epiphyseal diameter (Gnanaprakasam & Selvaraj, 2017; Rajanalini & Anitha, 2018). Using the difference between subglottic & cole's (29.4%): sample size = 49 per group.

    Patients aged from 1 to 6 years will be scheduled for elective surgery under general anesthesia and intubation, were enrolled in this study. Patients were randomly divided into three groups (49 patients each) according to method of choosing the tube size.

    Aged group (n =49): determined the optimal endotracheal tube size according to age of the child (internal diameter [ID] in mm = [age in years + 16] /4) suggested by Cole.4 Subglottic diameter group (n =49): The subglottic transverse diameter was estimated with ultrasonography on the middle of the anterior region of the neck at the level of cricoid cartilage.

    Epiphyseal diameter group (n =49): the epiphyseal transverse diameter of the distal radius was estimated with ultrasonography.

    Study design:

    A cross sectional observational study.

    Technique:

    An intravenous cannula was inserted and secured. General anesthesia was induced by inhalation of sevoflurane or intravenous administration of intravenous anesthetic as thiopental sodium (5 mg/kg). Muscular relaxation was achieved with atracurium (0.5mg/kg) to facilitate ETT intubation under direct laryngoscopy. The lungs were ventilated with 100% oxygen via a facemask before intubation.

    Size of the initial tube was selected as follows: Aged group determined ETT size according to age of the child (internal diameter [ID] in mm = [age in years + 16]/4) suggested by Cole.4 In subglottic diameter group, the subglottic diameter was estimated with B-mode ultrasonography (Korean, Siemens, Acuson, x300) with a 10-13-MHz linear probe positioned on the midline of the anterior neck. The evaluation began by identifying the true vocal folds as paired hyperechoic linear structures that moved with respiration and swallowing before patients were paralyzed. The probe was then moved caudally to visualize the cricoid arch which appears as an arched, rounded and hypoechoic structure. The transverse air-column diameter was measured at the lower edge of the cricoid cartilage after patients were paralyzed.

    The measurements of the subglottic diameter was used to select the size of the outer diameter of ETT by the equation [ETT OD=0.55*(subglottic diameter) +1.16, R2= 0.90 for un-cuffed].9 In epiphyseal diameter group , The epiphyseal transverse diameter of the distal radius was measured by B-mode ultrasonography (Korean, Siemens, Acuson, x300) with a 10-13-MHz linear probe, the internal diameter of ETT was selected by using the equation internal diameter of ETT (mm) = (29.5 + EpiRad [mm])/8 (EpiRad: transverse diameter of the distal radius).

    All tracheas were intubated with an uncuffed Mallinckrodt ETT with a Murphy's eye. The tracheal tube place was confirmed by auscultation.

    The correct ETT size was considered optimal when an audible air leak around the tube at an inspiratory airway pressure was detected between 10-30 cmH2O, with the head and neck in a neutral position. The presence of an air leak was assessed by closing off the pop-off valve and allowing pressure to rise slowly until an audible leak was heard using a stethoscope. If there was no audible leak when the lung were inflated to a pressure of 30 cm H2O, the tube was exchanged with one that was 0.5 mm smaller. But if a leak occurred at an inflation pressure of less than ten cm H2O, the ETT was exchanged for one with the 0.5 mm larger tube.

    Patient descriptive data, size of the selected ETT, number and size of the optimum tube, number of re-intubation due to incorrect size of ETT either smaller or larger were recorded. Subglottic transverse diameter (mm) and time of intubation were measured. After intubation, pulse, respiratory rate, arterial blood saturation, capnograghy and airway pressure were recorded during surgery.

    Any airway complications after extubation as edema, stenosis or stridor were also recorded.

    Statistical analysis:

    All the data from the three groups will be tabulated and compared with each other using the appropriate statistical methods according to the type of values whether parametric or non-parametric. P value <0.05 will be considered statistically significant.

    Study Design

    Study Type:
    Observational
    Anticipated Enrollment :
    147 participants
    Observational Model:
    Case-Control
    Time Perspective:
    Cross-Sectional
    Official Title:
    Comparison Between the Subglotic Diameter and the Epiphyseal Diameter of the Radius in Children for Prediction of Appropriate Endotracheal Tube Sizes
    Actual Study Start Date :
    Oct 1, 2018
    Anticipated Primary Completion Date :
    Jul 1, 2019
    Anticipated Study Completion Date :
    Aug 1, 2019

    Arms and Interventions

    Arm Intervention/Treatment
    Aged group (n =49)

    Determined the optimal endotracheal tube size according to age of the child (internal diameter [ID] in mm = [age in years + 16] /4) suggested by Cole

    Subglottic diameter group (n =49)

    The subglottic transverse diameter was estimated with ultrasonography on the middle of the anterior region of the neck at the level of cricoid cartilage

    Epiphyseal diameter group (n =49)

    The epiphyseal transverse diameter of the distal radius was estimated with ultrasonography.

    Outcome Measures

    Primary Outcome Measures

    1. number of the optimum tube size [3 months]

      number of the optimum tube size used in pediatric patients in each group

    Secondary Outcome Measures

    1. number of re-intubation [3 months]

      number of re-intubation due to incorrect size of ETT either smaller or larger in each group

    Other Outcome Measures

    1. time of intubation [3 months]

      time was taken for intubation in each group

    2. airway complications [3 months]

      airway complications after extubation as edema, stenosis or stridor

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    1 Year to 6 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    Yes
    Inclusion Criteria:
    • Patients aged from 1 to 6 years

    • scheduled for elective surgery under general anesthesia and intubation

    Exclusion Criteria:
    • Patients refusal

    • An anticipated difficult airway,

    • Any respiratory disease that might cause airway narrowing

    • Pre-exiting laryngeal or tracheal pathology

    • Any lesion that could cause airway deformity due to fibrosis or the presence of a neck anatomical pathologies that could affect the ultrasound evaluation of the airway

    • Any abnormality in the wrist and radius bone

    • Any disease after epiphyseal diameter as Rickets or skeletal dysplasia

    • Prolonged surgery more than 90 minutes

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 Gamal Zakaria Mansourah Egypt

    Sponsors and Collaborators

    • Mansoura University

    Investigators

    None specified.

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Nevert Adel, lecturer of anesthesia, surgical ICU and pain management, Mansoura University
    ClinicalTrials.gov Identifier:
    NCT03713385
    Other Study ID Numbers:
    • MansouraU4
    First Posted:
    Oct 19, 2018
    Last Update Posted:
    Mar 7, 2019
    Last Verified:
    Mar 1, 2019
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No