Comparison of Penile Oxygen Pressure.
Study Details
Study Description
Brief Summary
Aim of this study is to compare novel 3D printed cycling saddle with the best selling saddle from two major cycling manufacturers in terms of effects on blood circulation in the peritoneal region.
Condition or Disease | Intervention/Treatment | Phase |
---|---|---|
|
Detailed Description
The aim of this thesis is to investigate whether Joyseat's 3D printed and custom-made bicycle saddles provide a benefit in terms of increased penile blood flow compared to the best-selling saddles from two major bicycle manufacturers. The method chosen to measure blood flow, which is commonly used in studies of this type, is referred to as Near Infrared Spectroscopy. Measurement of tcpO2 and tcpCO2 in cyclists will be performed while riding on a cycling trainer using Radiometer TCM5 Flex (Radiometer Medical ApS, Brønshøj, Denmark) and a tc 84 electrode placed on the glans penis. Prior to the actual penile blood flow measurements, the sensitivity level of the n. pudendus (n. dorsalis penis) will be verified using biothesiometry (electronic tuning fork test, vibration), which is again commonly used in studies of this type. The pressure of the rider's contact surfaces on the saddle will be evaluated with pressure mat (Gebiomized GmbH, Münster, Germany). The Wahoo Bike (Wahoo Fitness, Limited Liability Company, Atlanta, Georgia, United States of America) will be used in the study, which, in addition to the possibility of individual seating adjustment, also allows to record the cyclist's power and heart rate using a chest strap. The cyclist's position on the bike will be measured and evaluated by infrared sensors and Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America). The test will be performed on the described instrumentation in the Applied Kinesiology Laboratory at Charles University in Prague, Faculty of Physical Education and Sports and will involve a maximum of 3x 20 min rides on the cycle trainer at 65-85% of the cyclist's maximum individual heart rate during one visit. All measurement methods and devices are non-invasive and painless. The choice of instruments was based on their use in previously published studies of similar type and on their quality, i.e., the parameters of validity, reliability, sensitivity, specificity and availability.
Study Design
Arms and Interventions
Arm | Intervention/Treatment |
---|---|
Group 1 Order of saddle testing: Joyseat saddle - Specialized Power saddle - Fizik Tundra M5 saddle |
Device: Biothesiometry
Biothesiometry using Biothesiometer (Bio Medical Instrument Co, Ohio, United States of America), placed on glans penis and second finger of nondominant hand.
Other Names:
Device: Near Infrared Spectroscopy
Penile oxygen pressure using TCM5 Flex and tc84 electrode (Radiometer Medical ApS, Brønshøj, Denmark) placed on glans penis.
Device: Cycling on a home trainer
Riding a static bike Wahoo Bike (Wahoo Fitness LLC, Atlanta, Georgia, United States of America) for 3x 10 minutes at 65-85% of each individual subjects maximal heart rate.
Device: Bike Fitting
Setting standardized posture of the rider on the bike using Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America)
|
Group 2 Order of saddle testing: Joyseat saddle - Fizik Tundra M5 saddle - Specialized Power saddle |
Device: Biothesiometry
Biothesiometry using Biothesiometer (Bio Medical Instrument Co, Ohio, United States of America), placed on glans penis and second finger of nondominant hand.
Other Names:
Device: Near Infrared Spectroscopy
Penile oxygen pressure using TCM5 Flex and tc84 electrode (Radiometer Medical ApS, Brønshøj, Denmark) placed on glans penis.
Device: Cycling on a home trainer
Riding a static bike Wahoo Bike (Wahoo Fitness LLC, Atlanta, Georgia, United States of America) for 3x 10 minutes at 65-85% of each individual subjects maximal heart rate.
Device: Bike Fitting
Setting standardized posture of the rider on the bike using Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America)
|
Group 3 Order of saddle testing: Specialized Power saddle - Fizik Tundra M5 saddle - Joyseat saddle |
Device: Biothesiometry
Biothesiometry using Biothesiometer (Bio Medical Instrument Co, Ohio, United States of America), placed on glans penis and second finger of nondominant hand.
Other Names:
Device: Near Infrared Spectroscopy
Penile oxygen pressure using TCM5 Flex and tc84 electrode (Radiometer Medical ApS, Brønshøj, Denmark) placed on glans penis.
Device: Cycling on a home trainer
Riding a static bike Wahoo Bike (Wahoo Fitness LLC, Atlanta, Georgia, United States of America) for 3x 10 minutes at 65-85% of each individual subjects maximal heart rate.
Device: Bike Fitting
Setting standardized posture of the rider on the bike using Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America)
|
Group 4 Order of saddle testing: Specialized Power saddle - Joyseat saddle - Fizik Tundra M5 saddle |
Device: Biothesiometry
Biothesiometry using Biothesiometer (Bio Medical Instrument Co, Ohio, United States of America), placed on glans penis and second finger of nondominant hand.
Other Names:
Device: Near Infrared Spectroscopy
Penile oxygen pressure using TCM5 Flex and tc84 electrode (Radiometer Medical ApS, Brønshøj, Denmark) placed on glans penis.
Device: Cycling on a home trainer
Riding a static bike Wahoo Bike (Wahoo Fitness LLC, Atlanta, Georgia, United States of America) for 3x 10 minutes at 65-85% of each individual subjects maximal heart rate.
Device: Bike Fitting
Setting standardized posture of the rider on the bike using Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America)
|
Group 5 Order of saddle testing: Fizik Tundra M5 saddle - Joyseat saddle - Specialized Power saddle |
Device: Biothesiometry
Biothesiometry using Biothesiometer (Bio Medical Instrument Co, Ohio, United States of America), placed on glans penis and second finger of nondominant hand.
Other Names:
Device: Near Infrared Spectroscopy
Penile oxygen pressure using TCM5 Flex and tc84 electrode (Radiometer Medical ApS, Brønshøj, Denmark) placed on glans penis.
Device: Cycling on a home trainer
Riding a static bike Wahoo Bike (Wahoo Fitness LLC, Atlanta, Georgia, United States of America) for 3x 10 minutes at 65-85% of each individual subjects maximal heart rate.
Device: Bike Fitting
Setting standardized posture of the rider on the bike using Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America)
|
Group 6 Order of saddle testing: Fizik Tundra M5 saddle - Specialized Power saddle - Joyseat saddle |
Device: Biothesiometry
Biothesiometry using Biothesiometer (Bio Medical Instrument Co, Ohio, United States of America), placed on glans penis and second finger of nondominant hand.
Other Names:
Device: Near Infrared Spectroscopy
Penile oxygen pressure using TCM5 Flex and tc84 electrode (Radiometer Medical ApS, Brønshøj, Denmark) placed on glans penis.
Device: Cycling on a home trainer
Riding a static bike Wahoo Bike (Wahoo Fitness LLC, Atlanta, Georgia, United States of America) for 3x 10 minutes at 65-85% of each individual subjects maximal heart rate.
Device: Bike Fitting
Setting standardized posture of the rider on the bike using Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America)
|
Outcome Measures
Primary Outcome Measures
- Difference in penile oxygen pressure on different types of saddles [Final comparison and data analysis of all anonymized values at the end of the research period within 4 months of end data collection]
Statistical comparison of values recorded in mmHg
Eligibility Criteria
Criteria
Inclusion Criteria:
- gender: male, age: 23-45years, discipline: road cycling, annual mileage: more than 7000km
Exclusion Criteria:
- Participants other than male, diagnosed with erectile dysfunction, acute or chronic back pain, acute (especially infectious) illness or injury, and in recovery from illness or injury are not eligible for inclusion in the research
Contacts and Locations
Locations
Site | City | State | Country | Postal Code | |
---|---|---|---|---|---|
1 | Charles University | Prague | Czechia | 162 52 |
Sponsors and Collaborators
- Charles University, Czech Republic
Investigators
- Principal Investigator: Jitka Malá, PhDr. Ph.D., Charles University
Study Documents (Full-Text)
None provided.More Information
Publications
None provided.- Snuparek, peritoneal area