Comparisons of the Astigmatic Power of Toric Intraocular Lens Using Three Toric Calculators: AcrySof, TECNIS, and iTrace Toric Calculator

Sponsor
Yonsei University (Other)
Overall Status
Completed
CT.gov ID
NCT01978106
Collaborator
(none)
100
1
3
33.8

Study Details

Study Description

Brief Summary

Purpose of this study is to compare the astigmatic power of the toric IOL obtained from the AcrySof toric calculator, TECNIS toric calculator, and iTrace toric calculator in a group of patients with preoperative with-the-rule (WTR) and against-the-rule (ATR) corneal astigmatism. The study included 100 eyes with cataract and greater than 0.75 diopter of corneal astigmatism, and the subjects were divided into WTR and ATR group. Keratometric value was measured using autokeratometry, IOLMaster partial coherence interferometry (PCI), iTrace incorporating corneal topography and ray-tracing aberrometry. Based on measured values, toric IOL power calculations were performed using AcrySof, TECNIS and iTrace toric calculators.

Condition or Disease Intervention/Treatment Phase

    Study Design

    Study Type:
    Observational
    Actual Enrollment :
    100 participants
    Observational Model:
    Cohort
    Time Perspective:
    Retrospective
    Study Start Date :
    Jan 1, 2013
    Actual Primary Completion Date :
    Apr 1, 2013
    Actual Study Completion Date :
    Apr 1, 2013

    Arms and Interventions

    Arm Intervention/Treatment
    a WTR corneal astigmatism group

    Corneal astigmatism was defined as WTR when the steep corneal cylinder axis was within 30 degrees of the horizontal axis.

    an ATR corneal astigmatism group

    Corneal astigmatism was defined as ATR when the cylinder axis was within 30 degrees of the vertical axis.

    Outcome Measures

    Primary Outcome Measures

    1. Difference of toric intraocular lens power between three toric calculators [Immediately after measurement]

      Comparison of the toric intraocular lens power calculated from Acrysof and TECNIS toric calculators using keratometric values measured by autokeratometry or IOLMaster PCI and that from iTrace toric calculator with keratometric value measurement using iTrace ray tracing wavefront aberrometry and iTrace simulated keratometry.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    33 Years to 87 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    Yes
    Inclusion Criteria:
    • Subjects who planned to undergo cataract removal by phacoemulsification

    • Subjects with preoperative corneal astigmatism greater than 0.75 D, as determined by autokeratometry

    Exclusion Criteria:
    • Subjects with more than 2.74 D of corneal keratometric value from autokeratometry

    • a history of intraocular or corneal surgery and ocular trauma

    • biomicroscopic evidence of corneal disease that could affect corneal astigmatisms

    • contact lens wearer

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine Seoul Korea, Republic of 120-752

    Sponsors and Collaborators

    • Yonsei University

    Investigators

    None specified.

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Yonsei University
    ClinicalTrials.gov Identifier:
    NCT01978106
    Other Study ID Numbers:
    • 1-2013-0041
    First Posted:
    Nov 7, 2013
    Last Update Posted:
    Nov 7, 2013
    Last Verified:
    Nov 1, 2013
    Keywords provided by Yonsei University
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Nov 7, 2013