Complementary Investigation of Perfusion and Anatomy Measures of the Heart With MRI and Combined PET/MRI

Sponsor
University of Zurich (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT05609214
Collaborator
(none)
200
48

Study Details

Study Description

Brief Summary

The goal of this observational study is to evaluate the complimentary information of anatomy, perfusion and viability of PET and MR. The main question[s] it aims to answer are:

  • to compare perfusion and anatomy measurements and perfusion related signals from PET and MR imaging and estimate its prognostic values.

  • to evaluate potential optimization of routine scanning procedure with re-gards to completeness and potential added value of quantitative measurements.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    Stress perfusion cardiac magnetic resonance (CMR), Cardiac Computed Tomography (CT) and Positron Emission Tomography (PET) are well-established non-invasive imaging tests that are in-creasingly being used for the assessment of patients with known or suspected ischemic heart dis-ease [1]. While all of these clinically established modalities have different characteristics and thus inherent advantages and disadvantages, none of them alone allows simultaneous exclusive visuali-zation of anatomic, functional, and metabolic features of the heart. Stress CMR provides an accu-rate assessment of cardiac function [2, 3], myocardial scar [4, 5], and myocardial ischemia [6-8]. However, stress perfusion CMR remains underutilized for the assessment of chest pain compared with other non-invasive methods [8]. This is in part due to cost, inadequate access to the technolo-gy, long scan times, and an insufficient number of physicians with expertise to interpret the images while automated analysis is not well established for CMR. On the other side, stress PET perfusion imaging can accurately assess myocardial scar and myocardial ischemia and has moreover the unique ability to quantify myocardial blood flow [9, 10].

    Given this discrepancy between the professional guidelines supporting the use of stress CMR and the lack of adoption into clinical practice, there is significant interest in developing: (A) more efficient and higher quality image acquisition and (B) more automated and quantitative image analysis approaches to improve the utilization of and access to stress CMR. One such improvement is the modification of the magnetic resonance imaging (MRI) pulse sequence currently used to assess myocardial perfusion so that it can also simultaneously be used to provide the information neces-sary to quantify myocardial blood flow [11]. Indeed when combined with a specially designed image analysis software, this modified pulse sequence provides images that can be used to automatically quantify myocardial blood flow on a pixel-by-pixel basis [12].

    Further improvements in the software used to acquire and analyse stress CMR images are needed to make this important diagnostic tool more accessible to patients that would benefit from it.

    Hence, the primary goal of this study is to compare in a larger patient sample perfusion and metabolism assessed by MR or complimentary by PET and MR in terms of identifying individuals with myocardial perfusion defects. Furthermore, in those patients where cardiac CT and invasive coro-nary angiography data is available (from clinical routine examinations), complimentary anatomy and perfusion measures of CT, PET, coronary angiography, and MR measurements will be as-sessed as well. Within this study a comparison of various assessments and possible readouts will be compared with regards values and parameters received. Typical readouts used in clinical routine and available automated algorithms will be used. The goal is to evaluate current clinical protocols, its benefits and potential optimization.

    Additionally, this study will submit data into a multi-centric data registry in order to efficiently test and validate potential of future technological developments in CMR. Therefore, the de-identified images and raw data acquired will be collected from multiple centers and stored at a HIPAA-compliant repository at University of Chicago Medicine and the University of Virgina. The images which would fulfill the criteria for this register will be further processed. The de-identified imaging and clinical data will be distributed to a Core Laboratory located at McGill University (Montreal, Canada) and also to other academic partners for image processing, image analysis, and software development. Additionally, downstream testing and patient outcomes will be collected as pilot data towards determining the clinical impact of automated quantitative myocardial blood flow analysis of stress CMR images.

    Study Design

    Study Type:
    Observational
    Anticipated Enrollment :
    200 participants
    Observational Model:
    Cohort
    Time Perspective:
    Prospective
    Official Title:
    COMPLEMENTARY INVESTIGATION OF PERFUSION AND ANATOMY MEASURES OF THE HEART WITH MRI AND COMBINED PET/MRI
    Anticipated Study Start Date :
    Dec 1, 2022
    Anticipated Primary Completion Date :
    Apr 1, 2026
    Anticipated Study Completion Date :
    Dec 1, 2026

    Outcome Measures

    Primary Outcome Measures

    1. Complimentary information on perfusion and metabolism [2 years]

      To evaluate complimentary information on perfusion and metabolism as-sessed by PET and MR imaging to better identify individuals with known or suspected coronary artery disease

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Male and Female participants over the age of 18 years

    • Written informed consent by the participant after information about the research project

    • Symptoms consistent with possible coronary artery disease

    • Clinical referral for a vasodilator stress CMR and/or PET exami-nation

    Exclusion Criteria:
    • Patients with high degree heart block

    • Contraindications to gadolinium-enhanced CMR examination

    • Severe claustrophobia

    • Specific implantable devices which are contraindicated for CMR

    • Current pregnancy

    • Advanced renal disease (GFR<30)

    • Uncontrolled obstructive pulmonary disease or asthma

    • Atrial fibrillation at the time of study enrolment

    Contacts and Locations

    Locations

    No locations specified.

    Sponsors and Collaborators

    • University of Zurich

    Investigators

    • Principal Investigator: Aju P Pazhenkottil, University of Zurich

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    University of Zurich
    ClinicalTrials.gov Identifier:
    NCT05609214
    Other Study ID Numbers:
    • 2021-02520
    First Posted:
    Nov 8, 2022
    Last Update Posted:
    Nov 8, 2022
    Last Verified:
    Nov 1, 2022
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by University of Zurich
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Nov 8, 2022