Contrast Sensitivity Assessment in Pediatric Cataract Surgery With IOL Implantation

Sponsor
Iladevi Cataract and IOL Research Center (Other)
Overall Status
Completed
CT.gov ID
NCT01901744
Collaborator
(none)
25
1
1
48
0.5

Study Details

Study Description

Brief Summary

The study evaluates contrast sensitivity in older children following surgery for lamellar and posterior subcapsular cataracts. Often, pediatric surgeons tend to delay surgery in these children who present beyond the amblyogenic age group. These cataracts are often compatible with reasonable visual acuity and therefore some surgeons prefer to wait for surgery, whereas others tend to operate.

The study evaluates improvement in contrast sensitivity at different spatial frequencies following cataract surgery for lamellar and posterior subcapsular cataracts in older children.

Condition or Disease Intervention/Treatment Phase
  • Procedure: Cataract Surgery
N/A

Detailed Description

All patients undergoes temporal clear corneal incision, manual anterior continuous curvilinear capsulorhexis, bimanual irrigation/aspiration for lens removal and residual cortex, posterior capsule management based on the age of the patient either manual posterior capsulorhexis (PCCC) upto 6 years or leaving intact posterior capsule and implantation of single-piece AcrySof SN60WF (Alcon Laboratories, Forth Worth, Texas) hydrophobic acrylic IOL in-the-bag. Postoperatively, all the patients are examined first for high contrast sensitivity and then for low contrast at 1 week, 1 and 3 months respectively.

The results are analyzed for corrected distance visual acuity (CDVA) which is recorded in LogMAR units at preoperative and 1 and 3 months postoperatively. Monocular high-contrast Snellen visual assessment for distance is done with the Early Treatment Diabetic Retinopathy Study chart (Vector Vision acuity chart at 100% contrast) with Corrected distance visual acuity CDVA at 4 m under photopic condition.

Similarly at preoperative and 1 and 3 months postoperatively contrast sensitivity testing is also performed using the CSV 1000E sine wave grating test face (Vector Vision, USA) with the patient seated at a distance of 2.5 m from the chart. The test is performed after the patient is adapted to the room luminance for 5 minutes. The non viewing eye was occluded for each measurement, and the best spectacle refractive correction is placed in front of the viewing eye. Testing is being tested under two lighting conditions: photopic (85cd/m2) and mesopic (2.7cd/m2). The contrast sensitivity values are documented in log units. Sensitivity levels at each frequency range from 0.7 to 2.08 (3 cpd), 0.91 to 2.29 (6 cpd), 0.61 to 1.99 (12 cpd), and 0.17 to 1.55 (18 cpd) log units. This testing is performed with the patient wearing their refractive correction in form of spectacles.

Study Design

Study Type:
Interventional
Actual Enrollment :
25 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
Contrast Sensitivity Assessment in Pediatric Cataract Surgery With IOL Implantation: A Comparison of Preoperative and Early Postoperative Outcomes
Study Start Date :
Jan 1, 2009
Actual Primary Completion Date :
Jul 1, 2011
Actual Study Completion Date :
Jan 1, 2013

Arms and Interventions

Arm Intervention/Treatment
Experimental: Patients undergoing cataract surgery

Procedure: Cataract Surgery

Outcome Measures

Primary Outcome Measures

  1. Contrast Sensitivity at 3, 6, 12 and 18 cycles per degree under photopic and mesopic conditions pre and post cataract surgery [up to 3 months postoperatively]

    Preoperative and 1 and 3 months postoperatively contrast sensitivity testing would performed using the CSV 1000E sine wave grating test face (Vector Vision, USA) with the patient seated at a distance of 2.5 m from the chart. The test is performed after the patient was adapted to the room luminance for 5 minutes. The non viewing eye is occluded for each measurement, and the best spectacle refractive correction is placed in front of the viewing eye. Testing is performed at preoperative 3, 6, 12 and 18 cycles per degree, each spatial frequency being tested under two lighting conditions: photopic (85cd/m2) and mesopic (2.7cd/m2). The contrast sensitivity values are documented in log units. Sensitivity levels at each frequency range from 0.7 to 2.08 (3 cpd), 0.91 to 2.29 (6 cpd), 0.61 to 1.99 (12 cpd), and 0.17 to 1.55 (18 cpd) log units. This testing is performed with the patient wearing their refractive correction in form of spectacles.

Secondary Outcome Measures

  1. Improvement in Best Corrected Snellen's Visual Acuity following Cataract Surgery [1 and 3 months postoperatively]

    Corrected distance visual acuity (CDVA) which IS recorded in LogMAR units at preoperative and 1 and 3 months postoperatively. Monocular high-contrast Snellen visual assessment for distance would be done with the Early Treatment Diabetic Retinopathy Study chart (Vector Vision acuity chart at 100% contrast) with Corrected distance visual acuity CDVA at 4 m under photopic condition.

Eligibility Criteria

Criteria

Ages Eligible for Study:
1 Year to 15 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Children older than 4 years and lamellar and posterior subcapsular cataracts undergoing cataract surgery with IOL implantation
Exclusion Criteria:
  • eyes with traumatic or subluxated cataract,

Contacts and Locations

Locations

Site City State Country Postal Code
1 Iladevi Cataract & IOL Research Centre Ahmedabad Gujarat India 380 052

Sponsors and Collaborators

  • Iladevi Cataract and IOL Research Center

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Abhay R. Vasavada, Director, Iladevi Cataract and IOL Research Center, Iladevi Cataract and IOL Research Center
ClinicalTrials.gov Identifier:
NCT01901744
Other Study ID Numbers:
  • 12-008
First Posted:
Jul 17, 2013
Last Update Posted:
Jul 17, 2013
Last Verified:
Jul 1, 2013
Keywords provided by Abhay R. Vasavada, Director, Iladevi Cataract and IOL Research Center, Iladevi Cataract and IOL Research Center