Evaluation of Safety and Efficacy of Lumason/SonoVue in Subjects Undergoing Pharmacologic Stress BR1-142

Sponsor
Bracco Diagnostics, Inc (Industry)
Overall Status
Completed
CT.gov ID
NCT02552238
Collaborator
(none)
174
13
1
28.5
13.4
0.5

Study Details

Study Description

Brief Summary

The purpose of this study was to assess the safety and efficacy of Lumason-enhanced dobutamine stress echo (DSE) in subjects having a suboptimal left ventricular endocardial border delineation (LV EBD) at rest and who were scheduled for coronary angiography.

Condition or Disease Intervention/Treatment Phase
Phase 3

Detailed Description

The study was designed to assess the safety and efficacy of Lumason at improving the visualization of the LV EBD during pharmacologic stress echocardiography examinations and for detection or exclusion of the coronary artery disease (CAD). The study population consisted of adult subjects referred for pharmacological stress echocardiography and with suboptimal image quality during unenhanced ultrasound imaging at rest who had known or suspected CAD. Subjects enrolled in the study represented subjects who could benefit most from CEUS stress echocardiography.

Study Design

Study Type:
Interventional
Actual Enrollment :
174 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
A Prospective Multicenter Phase III Clinical Evaluation of the Safety and Efficacy of Lumason™/SonoVue® in Subjects Undergoing Pharmacologic Stress Echocardiography With Dobutamine for the Diagnosis of Coronary Artery Disease
Actual Study Start Date :
Oct 12, 2015
Actual Primary Completion Date :
Jun 22, 2017
Actual Study Completion Date :
Feb 25, 2018

Arms and Interventions

Arm Intervention/Treatment
Experimental: Lumason

Lumason (sulfur hexafluoride lipid-type A microspheres) 2 mL IV injection

Drug: Lumason
Lumason (sulfur hexafluoride-type A microspheres) an ultrasound contrast agent was administered as 2 single 2-mL IV injections during rest and stress echocardiography
Other Names:
  • SonoVue
  • Outcome Measures

    Primary Outcome Measures

    1. Sensitivity and Specificity of Lumason Enhanced Dobutamine Stress Echo (DSE) for Detection or Exclusion of Coronary Artery Disease (CAD) [Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography were performed]

      The diagnostic performance of the echocardiographic images was compared to the truth standard to determine sensitivity and specificity. A diagnosis of CAD was determined for both the echo images and truth standard (positive diagnosis for CAD is defined as >/= 50% stenosis of any vessel on coronary angiography or if no coronary angiography was performed the occurence of a cardiac event based on clinical information for up to 6 months post dose; otherwise the diagnosis was negative). Results for sensitivity and specificity are reflected based on difference between contrast enhanced stress echo and unenhanced stress echo. Results for analysis of data based on majority assessment from the three off-site blinded readers are presented. Sensitivity and specificity are the percentages of correctly diagnosed subjects by stress echo over the total positive and negative subjects according to the truth standard respectively.

    2. Reader-Specific Percentages of Participants Identified as Having a Critical Shift From Suboptimal to Optimal Echocardiographic Images [Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography was performed]

      The percentage of subjects with suboptimal images (defined as >= 2 adjacent segments with inadequate LV EBD in any of the 3 apical views) at unenhanced stress echo converted to adequate (reduction of suboptimal segments in any of the 3 apical views) at contrast-enhanced stress echo

    Secondary Outcome Measures

    1. Change in Total LV EBD [Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography was performed]

      Measured as the change in the total LV EBD score based on the 17 segments, from peak stress unenhanced vs. peak stress contrast-enhanced. Total LV EBD score ranges from 0 to 34 and higher score is better outcome.

    2. Number of Participants With Adverse Events [72 hours post dose]

      To obtain safety data in subjects administered Lumason during echocardiography

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Provided written Informed Consent and comply with protocol requirements;

    • Was at least 18 years of age;

    • Had suspected of having CAD and undergoing coronary angiography within 6 months after the LUMASON DSE.

    • Had undergone a previous echocardiography prior to enrollment; resulting in suboptimal unenhanced images at rest, defined as ≥ 2 suboptimal adjacent segments in any apical view.

    Exclusion Criteria:

    • Was a pregnant or lactating female. Exclude the possibility of pregnancy: by testing on site at the institution (serum or urine βHCG) within 24 hours prior to the start of LUMASON administration(s), by surgical history (e.g., tubal ligation or hysterectomy), post menopausal with a minimum 1 year without menses;

    • Had any known hypersensitivity to 1 or more ingredients of LUMASON (sulfur hexafluoride or to any components of LUMASON);

    • Had any known hypersensitivity to dobutamine;

    • Had an ongoing or recent (within the last 30 days) acute myocardial infarction;

    • Had known right-to-left, bidirectional or transient cardiac shunt (ruled out with agitated saline study performed before administration of LUMASON);

    • Had electrolyte (especially potassium and magnesium) abnormalities;

    • Had unstable pulmonary and/or systemic hemodynamic conditions e.g.:

    decompensated or inadequately controlled congestive heart failure (NYHA Class IV);

    • hypovolemia;

    • uncontrolled hypertension, i.e. resting systolic blood pressure >200 mmHg or diastolic blood pressure >110 mmHg;

    • unstable angina;

    • acute coronary syndrome;

    • aortic dissection;

    • acute pericarditis,

    • myocarditis, or endocarditis;

    • stenosis of the main left coronary artery;

    • hemodynamically significant outflow obstruction of the left ventricle, including hypertrophic obstructive cardiomyopathy;

    • hemodynamically significant cardiac valvular defect;

    • acute pulmonary embolism;

    • Had uncontrolled cardiac arrhythmias;

    • Had significant disturbance in conduction;

    • Had hypertrophic subaortic stenosis;

    • Had an acute illness (e.g., infections, hyperthyroidism, or severe anemia);

    • Was previously entered into this study or received an investigational compound within 30 days before admission into this study;

    • Had been treated with any other contrast agent either intravascularly or orally within 48 hours of the first LUMASON administration;

    • Had any medical condition or other circumstances which would significantly decrease the chances of obtaining reliable data, achieving study objectives, or completing the study and/or postdose follow-up examinations;

    In addition, due to the use of Atropine in subjects who had not reached targeted heart rate with peak dobutamine infusion, subjects with the following were excluded:

    • Glaucoma;

    • Pyloric stenosis;

    • Prostatic hypertrophy.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 Coastal Multi-Specialty Research, Coastal Heart Medical Group Santa Ana California United States 92704
    2 Alfieri Cardiology Wilmington Delaware United States 19803
    3 Homestead Cardiac and Vein Center Homestead Florida United States 33030
    4 Ochsner Clinic Foundation New Orleans Louisiana United States 70121
    5 St. Louis University Hospital Saint Louis Missouri United States 63110
    6 University of Nebraska Medical Center Omaha Nebraska United States 68198
    7 Duke University Medical Center Cardiac Diagnostic Unit Durham North Carolina United States 27710
    8 University of Texas Medical Branch at Galveston Galveston Texas United States 77555
    9 Cliniques Universitaires Saint-Luc Unité de Pathologie Cardio-Vasculaire / Cardiologie Bruxelles Belgium 1200
    10 Antwerp University Hospital Edegem Belgium 2650
    11 St. Michael's Hospital Toronto Ontario Canada M5B 1W8
    12 Northwick Park Hospital Harrow Middlesex United Kingdom HA1 3UJ
    13 Hammersmith Hospital London United Kingdom W12 0HS

    Sponsors and Collaborators

    • Bracco Diagnostics, Inc

    Investigators

    • Study Director: Melda Dolan, MD, Bracco Diagnostics, Inc

    Study Documents (Full-Text)

    More Information

    Publications

    None provided.
    Responsible Party:
    Bracco Diagnostics, Inc
    ClinicalTrials.gov Identifier:
    NCT02552238
    Other Study ID Numbers:
    • BR1-142
    First Posted:
    Sep 17, 2015
    Last Update Posted:
    Jul 7, 2021
    Last Verified:
    Aug 1, 2018
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Keywords provided by Bracco Diagnostics, Inc
    Additional relevant MeSH terms:

    Study Results

    Participant Flow

    Recruitment Details
    Pre-assignment Detail
    Arm/Group Title Lumason
    Arm/Group Description Lumason (sulfur hexafluoride lipid-type A microspheres) 2 mL IV injection Lumason: Lumason (sulfur hexafluoride-type A microspheres) an ultrasound contrast agent was administered as 2 single 2-mL IV injections during rest and stress echocardiography
    Period Title: Overall Study
    STARTED 174
    COMPLETED 170
    NOT COMPLETED 4

    Baseline Characteristics

    Arm/Group Title Lumason
    Arm/Group Description Lumason (sulfur hexafluoride lipid-type A microspheres) 2 mL IV injection Lumason: Lumason (sulfur hexafluoride-type A microspheres) an ultrasound contrast agent was administered as 2 single 2-mL IV injections during rest and stress echocardiography
    Overall Participants 172
    Age (Count of Participants)
    <=18 years
    0
    0%
    Between 18 and 65 years
    102
    59.3%
    >=65 years
    70
    40.7%
    Age (years) [Mean (Standard Deviation) ]
    Mean (Standard Deviation) [years]
    61.9
    (11.02)
    Sex: Female, Male (Count of Participants)
    Female
    67
    39%
    Male
    105
    61%
    Race (NIH/OMB) (Count of Participants)
    American Indian or Alaska Native
    0
    0%
    Asian
    21
    12.2%
    Native Hawaiian or Other Pacific Islander
    0
    0%
    Black or African American
    24
    14%
    White
    103
    59.9%
    More than one race
    24
    14%
    Unknown or Not Reported
    0
    0%
    Height (cm) [Mean (Standard Deviation) ]
    Mean (Standard Deviation) [cm]
    169.4
    (10.58)
    Weight (kg) [Mean (Standard Deviation) ]
    Mean (Standard Deviation) [kg]
    86.98
    (21.631)
    BMI (kg/m^2) [Mean (Standard Deviation) ]
    Mean (Standard Deviation) [kg/m^2]
    30.24
    (6.849)

    Outcome Measures

    1. Primary Outcome
    Title Sensitivity and Specificity of Lumason Enhanced Dobutamine Stress Echo (DSE) for Detection or Exclusion of Coronary Artery Disease (CAD)
    Description The diagnostic performance of the echocardiographic images was compared to the truth standard to determine sensitivity and specificity. A diagnosis of CAD was determined for both the echo images and truth standard (positive diagnosis for CAD is defined as >/= 50% stenosis of any vessel on coronary angiography or if no coronary angiography was performed the occurence of a cardiac event based on clinical information for up to 6 months post dose; otherwise the diagnosis was negative). Results for sensitivity and specificity are reflected based on difference between contrast enhanced stress echo and unenhanced stress echo. Results for analysis of data based on majority assessment from the three off-site blinded readers are presented. Sensitivity and specificity are the percentages of correctly diagnosed subjects by stress echo over the total positive and negative subjects according to the truth standard respectively.
    Time Frame Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography were performed

    Outcome Measure Data

    Analysis Population Description
    The analysis population for CAD included all subjects who received Lumason, had an overall diagnostic conclusion of CAD available at peak stress for both UE-DSE and CE-DSE, and had a definite truth standard diagnosis (Positive, Negative) for CAD (coronary angiography or 6 months collection of cardiac events follow-up data).
    Arm/Group Title CE-DSE - UE-DSE
    Arm/Group Description Difference between CE-DSE and UE-DSE (CE-DSE - UE-DSE)
    Measure Participants 168
    Sensitivity
    16.0
    9.3%
    Specificity
    37.9
    22%
    Statistical Analysis 1
    Statistical Analysis Overview Comparison Group Selection CE-DSE - UE-DSE
    Comments Sensitivity: superiority test comparing CE-DSE and UE-DSE based on the difference
    Type of Statistical Test Superiority
    Comments
    Statistical Test of Hypothesis p-Value 0.0067
    Comments
    Method McNemar
    Comments
    Statistical Analysis 2
    Statistical Analysis Overview Comparison Group Selection CE-DSE - UE-DSE
    Comments Specificity: superiority test comparing CE-DSE and UE-DSE based on the difference
    Type of Statistical Test Superiority
    Comments
    Statistical Test of Hypothesis p-Value <0.0001
    Comments
    Method McNemar
    Comments
    2. Primary Outcome
    Title Reader-Specific Percentages of Participants Identified as Having a Critical Shift From Suboptimal to Optimal Echocardiographic Images
    Description The percentage of subjects with suboptimal images (defined as >= 2 adjacent segments with inadequate LV EBD in any of the 3 apical views) at unenhanced stress echo converted to adequate (reduction of suboptimal segments in any of the 3 apical views) at contrast-enhanced stress echo
    Time Frame Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography was performed

    Outcome Measure Data

    Analysis Population Description
    The analysis population for EBD included all subjects who received Lumason and had EBD data available at peak stress for both UE-DSE and CE-DSE.
    Arm/Group Title Reader 1 Reader 2 Reader 3
    Arm/Group Description Reader 1 CE-DSE Reader 2 CE-DSE Reader 3 CE-DSE
    Measure Participants 167 167 167
    Number (95% Confidence Interval) [percentage of participants]
    93.2
    54.2%
    89.8
    NaN
    93.5
    NaN
    3. Secondary Outcome
    Title Change in Total LV EBD
    Description Measured as the change in the total LV EBD score based on the 17 segments, from peak stress unenhanced vs. peak stress contrast-enhanced. Total LV EBD score ranges from 0 to 34 and higher score is better outcome.
    Time Frame Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography was performed

    Outcome Measure Data

    Analysis Population Description
    The analysis population for EBD included all subjects who received Lumason and had EBD data available at peak stress for both UE-DSE and CE-DSE.
    Arm/Group Title UE-DSE CE-DSE Difference
    Arm/Group Description Unenhanced Stress Echocardiography Contrast-enhanced Stress Echocardiography CE-DSE - UE-DSE
    Measure Participants 167 167 167
    Reader 1
    16.6
    (7.32)
    30.7
    (4.30)
    14.1
    (7.35)
    Reader 2
    20.5
    (8.36)
    31.6
    (5.93)
    11.1
    (8.65)
    Reader 3
    12.1
    (8.00)
    29.5
    (7.06)
    17.3
    (9.20)
    4. Secondary Outcome
    Title Number of Participants With Adverse Events
    Description To obtain safety data in subjects administered Lumason during echocardiography
    Time Frame 72 hours post dose

    Outcome Measure Data

    Analysis Population Description
    Safety analysis population includes all subjects who received Lumason
    Arm/Group Title Lumason
    Arm/Group Description All patients were administered, Lumason (sulphur hexafluoride lipid-type A microspheres) an ultrasound contrast agent as a single 0.03 mL/kg bolus injection during echocardiography.
    Measure Participants 172
    Number of subjects with AEs
    18
    10.5%
    Number of subjects with AEs by intensity - Mild
    10
    5.8%
    Number of subjects with AEs by intensity -Moderate
    5
    2.9%
    Number of subjects with AEs by intensity - Severe
    3
    1.7%
    Number of subjects with serious AEs
    3
    1.7%
    Number of subjects who discontinued due to AE
    2
    1.2%

    Adverse Events

    Time Frame All AEs that occurred from the time the subject signed the ICF until 72 hours after the last administration of Lumason or until the subject underwent cardiac intervention, whichever came first, were [recorded] listed, [with predose AEs flagged in the subject data listings.]
    Adverse Event Reporting Description
    Arm/Group Title Lumason
    Arm/Group Description Lumason (sulfur hexafluoride lipid-type A microspheres) 2 mL IV injection Lumason: Lumason (sulfur hexafluoride-type A microspheres) an ultrasound contrast agent was administered as 2 single 2-mL IV injections during rest and stress echocardiography
    All Cause Mortality
    Lumason
    Affected / at Risk (%) # Events
    Total 0/172 (0%)
    Serious Adverse Events
    Lumason
    Affected / at Risk (%) # Events
    Total 3/172 (1.7%)
    Cardiac disorders
    Myocardial Ischemia 1/172 (0.6%) 1
    Ventricular Fibrillation 1/172 (0.6%) 1
    Investigations
    Electrocardiogram ST Segment Elevation 1/172 (0.6%) 1
    Other (Not Including Serious) Adverse Events
    Lumason
    Affected / at Risk (%) # Events
    Total 18/172 (10.5%)
    Cardiac disorders
    Atrial fibrillation 1/172 (0.6%) 1
    Gastrointestinal disorders
    Nausea 2/172 (1.2%) 2
    General disorders
    Chest pain 5/172 (2.9%) 5
    Infections and infestations
    Urinary tract infection 1/172 (0.6%) 1
    Investigations
    Blood creatinine increased 1/172 (0.6%) 1
    Blood glucose increased 1/172 (0.6%) 1
    Troponin increased 1/172 (0.6%) 1
    Nervous system disorders
    Dysgeusia 1/172 (0.6%) 1
    Headache 2/172 (1.2%) 2
    Hypoesthesia 2/172 (1.2%) 2
    Psychiatric disorders
    Panic attack 1/172 (0.6%) 1
    Respiratory, thoracic and mediastinal disorders
    Dyspnea 1/172 (0.6%) 1

    Limitations/Caveats

    [Not Specified]

    More Information

    Certain Agreements

    Principal Investigators are NOT employed by the organization sponsoring the study.

    There is NOT an agreement between Principal Investigators and the Sponsor (or its agents) that restricts the PI's rights to discuss or publish trial results after the trial is completed.

    Results Point of Contact

    Name/Title Melda S. Dolan, MD, FACC, FASE, Head, Medical Affairs and Cardiac Ultrasound
    Organization Bracco Diagnostics Inc.
    Phone 1-609-514-2506
    Email Melda.Dolan@diag.bracco.com
    Responsible Party:
    Bracco Diagnostics, Inc
    ClinicalTrials.gov Identifier:
    NCT02552238
    Other Study ID Numbers:
    • BR1-142
    First Posted:
    Sep 17, 2015
    Last Update Posted:
    Jul 7, 2021