Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease

Sponsor
Sino Medical Sciences Technology Inc. (Industry)
Overall Status
Not yet recruiting
CT.gov ID
NCT05509296
Collaborator
Peking University First Hospital (Other)
136
2
4.6

Study Details

Study Description

Brief Summary

The objective of this study is to evaluate safety and effectiveness of the SINOMED CBC coronary dilatation catheter during PCI in subjects with stenotic coronary arteries.

Condition or Disease Intervention/Treatment Phase
  • Device: SINOMED CBC
  • Device: NSE Coronary Dilatation Catheter
N/A

Detailed Description

The investigation is a prospective, multi-center, randomized control, non-inferiority clinical study. The study will be conducted in up to 8 investigational sites in the China This study will enroll and treat 136 subjects, including in-stent restenosis (ISR). The population for this study is subjects with stenotic coronary artery disease who are suitable candidates for PTCA.

After screening for initial inclusion and exclusion criteria, eligible subjects will be asked to participate in the study by signing a consent form. Following consent, subjects will undergo a baseline visit where eligibility criteria will be assessed. Then, subjects will be randomized to either trial balloon (Sino Medical Sciences Technology Inc. ) or to a NSE Coronary Dilatation Catheter (Goodman Co.,Ltd). Angiograms will be performed before and after intervention.

Subjects will be followed through hospital discharge.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
136 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Intervention Model Description:
A prospective, multicenter, randomized control,non-inferiority clinical studyA prospective, multicenter, randomized control,non-inferiority clinical study
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
A Prospective, Multicenter, Randomized Control, Non-inferiority to Investigate the Effectiveness and Safety of SINOMED CBC for Endovascular Treatment of Stenotic Coronary Artery Disease
Anticipated Study Start Date :
Aug 23, 2022
Anticipated Primary Completion Date :
Dec 31, 2022
Anticipated Study Completion Date :
Jan 10, 2023

Arms and Interventions

Arm Intervention/Treatment
Experimental: SINOMED CBC

Cutting balloon catheter (Sino Medical Sciences Technology Inc.)

Device: SINOMED CBC
The Coronary Dilatation Balloon Catheter is indicated for the treatment of hemodynamically significant coronary artery stenosis, including in-stent restenosis and complex type C lesions, for the purpose of improving myocardial perfusion.
Other Names:
  • cutting balloon catheter
  • scoring balloon catheter
  • Active Comparator: NSE Coronary Dilatation Catheter

    NSE Coronary Dilatation Catheter (Goodman Co.,Ltd)

    Device: NSE Coronary Dilatation Catheter
    The Coronary Dilatation Balloon Catheter is indicated for the treatment of hemodynamically significant coronary artery stenosis, including in-stent restenosis and complex type C lesions, for the purpose of improving myocardial perfusion.
    Other Names:
  • Lacrosse NSE
  • Outcome Measures

    Primary Outcome Measures

    1. Rate of Device procedural success (lesion level) [immediate post-intervention(approximately 1.4 hour)]

      Defined as: Successful delivery, inflation, deflation, and withdrawal of the study balloon; and ≤30% final diameter stenosis following completion of the interventional procedure, including adjunctive stenting (For ISR or DCB related stenosis, Final diameter stenosis<50%)

    Secondary Outcome Measures

    1. Rate of Procedural success (patient level) [during the hospital stay, an average of 7 days post-procedure]

      Defined as: ≤30% final diameter stenosis following completion of the interventional procedure, including adjunctive stenting (For ISR or DCB related stenosis, Final diameter stenosis<50%); and freedom from major adverse cardiac events (MACE) during hospitalization

    2. Rate of Target lesion failure (TLF) [during the hospital stay, an average of 7 days post-procedure]

      a composite of cardiac death, target vessel myocardial infarction, or clinically-driven target lesion revascularisation (CI-TLR)

    3. Rate of Patient-oriented composite endpoint (POCE) [during the hospital stay, an average of 7 days post-procedure]

      a composite of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization

    4. Incidence of any AE and SAE incidence [during the hospital stay, an average of 7 days post-procedure]

      report any AE results from a device deficiency or other device issue as related to the use of the study device. Such as Balloon burst、vascular perforation, dissection, acute occlusion, vasospasm, thrombosis (including stent thrombosis), arrhythmia requiring intervention, and so on.

    5. Rate of device defect [during the hospital stay, an average of 7 days post-procedure]

      report any device defect during hospitalization

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 75 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    1. The patient is at least 18 to 75 years of age, male or not pregnant female.

    2. Evidence of myocardial ischemia without symptoms, stable or unstable angina, silent ischemia demonstrated by positive territorial functional study, or old myocardial infarction.

    3. De novo or restenotic lesion(s) in native coronary arteries, including in-stent restenosis.

    4. Reference vessel diameter (RVD) must be visually estimated ≥ 2.5 and ≤ 5.0mm, and the vessel length must be no more than 30mm.

    5. Target lesion(s) must have a diameter stenosis of (a) ≥70% by visual estimation or (b)

    50% with evidence of ischemia.

    1. The patient has a planned intervention at no more than two de novo lesions, in different epicardial vessels.

    2. Investigators believe that target lesion atherosclerotic plaques require spinous balloon treatment and balloon can be passed through by pre-dilation.

    3. Able to understand the purpose of the trial, voluntarily participate and sign the informed consent.

    Exclusion Criteria:
    1. Evidence of ongoing acute myocardial infarction within a week.

    2. Chronic total occlusion (TIMI 0), left main lesion, intervention-required three-vessel lesions, and bypass lesion.

    3. Severe calcification and Target lesion in a severe angulation (> 45 degrees).

    4. Patient has serious heart failure symptoms (NYHA level III or IV), or Left ventricular ejection fraction (LVEF) <40%.

    5. Patient with renal dysfunction, as Cr>176.82umol/L or Cr >2.0 mg/dl.

    6. Patient with active gastrointestinal bleeding history, any other evidence based bleeding, such as suspected liver failure disease, suffered from cerebral bleeding history, stroke during the last 6 months, with contra-indication of anti-platelet or anti-coagulation.

    7. Patients with allergies to heparin and contrast media.

    8. Target lesion demonstrating severe dissection prior to planned deployment of the trial device.

    9. Visible thrombus at the target lesion.

    10. Patients received heart transplantation.

    11. Participation in another clinical trial (12 months after index procedure).

    12. Those who participated in another clinical trials, but did not reach the primary endpoint.

    Contacts and Locations

    Locations

    No locations specified.

    Sponsors and Collaborators

    • Sino Medical Sciences Technology Inc.
    • Peking University First Hospital

    Investigators

    • Principal Investigator: jianping li, M.D/Ph.D, Peking University First Hospital

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Sino Medical Sciences Technology Inc.
    ClinicalTrials.gov Identifier:
    NCT05509296
    Other Study ID Numbers:
    • SN-CBC-202201
    First Posted:
    Aug 22, 2022
    Last Update Posted:
    Aug 25, 2022
    Last Verified:
    Aug 1, 2022
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by Sino Medical Sciences Technology Inc.
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Aug 25, 2022