Validity of Fractional Exhaled Nitric Oxide and Impulse Oscillometry in Patients With Cough Variant Asthma

Sponsor
Zhujiang Hospital (Other)
Overall Status
Completed
CT.gov ID
NCT03573284
Collaborator
(none)
146
1
1
10.6
13.8

Study Details

Study Description

Brief Summary

The aim of the research is to evaluate the clinical value of fractional exhaled nitric oxide(FeNO) ,impulse oscillometry(IOS) and mid-expiratory flow (MEF) in patients with cough variant asthma.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: fractional exhaled nitric oxide(FeNO)
  • Diagnostic Test: impulse oscillometry(IOS)
N/A

Detailed Description

The present study has the following objectives:

to evaluate the relationship between BHR and mid-expiratory flow, to assess the diagnostic accuracy of fractional exhaled nitric oxide,impulse oscillometry and mid-expiratory flow in CVA with special regard to its discriminating value between CVA and other causes of a chronic cough, to estimate prognostic value of BHR and fractional exhaled nitric oxide (FeNO) count in predicting response to asthma treatment.

Study Design

Study Type:
Interventional
Actual Enrollment :
146 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Evaluating the Efficacy of Fractional Exhaled Nitric Oxide and Impulse Oscillometry in Patients With Cough Variant Asthma
Actual Study Start Date :
Aug 12, 2018
Actual Primary Completion Date :
Jun 30, 2019
Actual Study Completion Date :
Jun 30, 2019

Arms and Interventions

Arm Intervention/Treatment
Experimental: Asthma group

Patients with chronic nonproductive cough for more than 8 weeks based on physician's opinion will be subjected to FeNO, impulse oscillometry(IOS) and pulmonary function. Receiver operating characteristic (ROC) curves to evaluate the clinical value of FeNO and small airways indices in CVA diagnosis. The optimal cutoff point for the level of FeNO and IOS is also determined.

Diagnostic Test: fractional exhaled nitric oxide(FeNO)
FeNO level was evaluated according to the American Thoracic Society (ATS)/ERS recommendations using a NIOX MINO analyzer (Aerocrine, Solna, Sweden) .Subjects were informed to deeply inhale NO-free air and immediately exhale in full via a mouthpiece at a constant flow rate (50 ml/s) for 10s.

Diagnostic Test: impulse oscillometry(IOS)
The patient take seats, body relax, make sure the mouthpiece is fully covered by mouth, then clip nose with both hands to cover both sides of the cheek, and then calm breathing 1 minutes, the computer is automatically collected data calculation and print out the measurement results.

Outcome Measures

Primary Outcome Measures

  1. the value of fractional exhaled nitric oxide(FeNO) in patients with cough variant asthma [at least 4 weeks of treatment]

    FENO will be performed by using a hand-held portable machine (NIOX MINO, Aerocrine AB, Solna, Sweden) at a standard flow rate of 50 mL/s, in accordance with ATS/ERS recommendations.

  2. the value of impulse oscillometry(IOS) in patients with cough variant asthma [at least 4 weeks of treatment]

    R5-R20(respiratory resistance)is measure by Jaeger MasterScreen Pulmonary

Secondary Outcome Measures

  1. the value of forced mid-expiratory flow (MMEF) in patients with cough variant asthma [at least 4 weeks of treatment]

    MMEF will be performed with a spirometer (Jaeger, Hoechberg, Germany) in accordance with the specifications and performance criteria recommended in the American Thoracic Society (ATS)/European Respiratory Society (ERS) Standardization of Spirometry

  2. the value of BHR and fractional exhaled nitric oxide (FeNO) count in predicting response to asthma treatment [at least 4 weeks of treatment]

    MCH bronchial provocation tests will be performed with the Jaeger APS Pro system.Provocative dose causing a 20% fall in FEV1(PD20) will be recorded, and BHR is defined as present if PD20≤0.48 mg. FENO is measure by a hand-held portable machine(NIOX MINO, Aerocrine AB, Solna, Sweden)

  3. the relationship between BHR and mid-expiratory flow [at least 4 weeks of treatment]

    BHR is measure by Jaeger APS Pro system.MMEF will be performed with a spirometer (Jaeger, Hoechberg, Germany)

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 65 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:

age 18-65 years old. Cough as the sole or predominant symptom lasting for at least 8 weeks, with no radiographic evidence of lung diseases.

Exclusion Criteria:

treatment of any oral corticosteroid in the last 4 weeks, and respiratory tract infection within 8 weeks.

smoking (min. 6 months) had asthma or other lung diseases, including obliterative bronchiolitis, bronchiectasis,and cystic fibrosis.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Huapeng Yu Guangzhou Guangdong China

Sponsors and Collaborators

  • Zhujiang Hospital

Investigators

  • Principal Investigator: Yu Hupeng, Southern Medical University, China

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Zhujiang Hospital
ClinicalTrials.gov Identifier:
NCT03573284
Other Study ID Numbers:
  • 2018-HXNK-002
First Posted:
Jun 29, 2018
Last Update Posted:
Jul 28, 2021
Last Verified:
Jul 1, 2021
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Zhujiang Hospital
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jul 28, 2021