Clinical Evaluation of the Panbio™ COVID-19/Flu A&B Rapid Panel Professional Use Product Using Mid-Turbinate Nasal Swabs

Sponsor
Abbott Rapid Dx (Industry)
Overall Status
Recruiting
CT.gov ID
NCT05630365
Collaborator
(none)
1,531
1
1
12.6
122

Study Details

Study Description

Brief Summary

This study is designed as an international, prospective, multicentric, clinical study to investigate the performance of the Panbio™ COVID-19/Flu A&B Rapid Panel for the qualitative detection of COVID-19 antigen, Influenza A antigen, and Influenza B antigen in human mid-turbinate nasal swabs collected by a trained health worker. This study is part of the performance evaluation to support the CE conformity assessment procedures.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: Panbio™
N/A

Detailed Description

A minimum of 1531 male and female subjects will be prospectively enrolled at multiple clinical sites to assess the performance of the Panbio™ Rapid Panel in detecting predominant Covid-19 and Flu variants currently in global circulation. A minimum of 120 Flu A reference positive subjects, a minimum of 120 Flu B reference positive subjects and a minimum of 300 SARS-CoV-2 reference positive subjects will be enrolled. In addition, a minimum of 991 reference negative subjects will be enrolled.

After informed consent has been obtained, operators will collect one mid-turbinate nasal swab sample from both nostrils from each subject. The nasal collection procedure will be a mid-turbinate nasal swab (deep nasal swab), by turning the swab five times in each nostril. Mid-turbinate nasal samples must be collected prior to the NP sampling. The collected mid-turbinate nasal swab will be tested with the Panbio™ Rapid Panel by an operator at the study site in a Near Patient Testing setting (e.g. GP centre or hospital clinic).

After the mid-turbinate nasal sampling, the operators will collect one NP swab sample from one nostril of each subject. NP sampling should be performed by trained healthcare professionals who routinely conduct NP sampling as part of their other standard of care and clinical duties. The collected NP swab will be eluted in UTM, provided by Abbott/the Core Laboratory, labelled and stored, according to the laboratory manual. UTM samples will be shipped to the Core Laboratory for testing with RT-PCR protocols for Flu A, Flu B and SARS-CoV-2, as per the laboratory manual. The RT-PCR methods used by the Core Laboratory will be CE marked and FDA cleared, with COVID-19 and Flu assay clearance for NP specimens. Leftover UTM from running RT-PCR should be labelled with subject ID and frozen at -80oC.Discordant results will be investigated as outlined in the laboratory manual.

All other aspects of the subject's care will remain the same with no deviation from prescribed practice. If additional Nasal/NP sampling is required, this must be done after the study procedures outlined in this clinical protocol.

Each operator who performs a Panbio™ COVID-19/Flu A&B Rapid Panel test will fill out a user evaluation questionnaire once, to assess the usability of the device.

Each subject's demographic information, symptomology data, and professionally performed test result and questionnaire will be recorded on source documentation and transferred to an Electronic Data Capture system.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
1531 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Clinical Evaluation of the Panbio™ COVID-19/Flu A&B Rapid Panel Professional Use Product Using Mid-Turbinate Nasal Swabs
Anticipated Study Start Date :
Dec 15, 2022
Anticipated Primary Completion Date :
Jan 1, 2024
Anticipated Study Completion Date :
Jan 1, 2024

Arms and Interventions

Arm Intervention/Treatment
Experimental: Nasal sampling/Testing (Professional Use)

operators will collect one mid-turbinate nasal swab sample from both nostrils from each subject. The collected mid-turbinate nasal swab will be tested with the Panbio™ Rapid Panel by an operator at the study site in a Near Patient Testing setting (e.g. GP centre or hospital clinic). After the mid-turbinate nasal sampling, the operators will collect one NP swab sample from one nostril of each subject.UTM samples will be shipped to the Core Laboratory for testing with RT-PCR protocols for Flu A, Flu B and SARS-CoV-2, as per the laboratory manual

Diagnostic Test: Panbio™
The Panbio™ COVID-19/Flu A&B Rapid Panel device, hereafter referred to as the Panbio™ Rapid Panel, is a visual lateral flow assay for the rapid immuno-chromatographic qualitative detection of COVID-19 antigen, Influenza A antigen, and Influenza B antigen in mid-turbinate nasal swabs
Other Names:
  • Panbio™ COVID-19/Flu A&B Rapid Panel Professional Use Product
  • Outcome Measures

    Primary Outcome Measures

    1. Primary Outcome: [immediate]

      Evaluate the clinical performance (sensitivity/specificity) of the Panbio™ COVID-19/Flu A&B Rapid Panel in fresh collected mid-turbinate nasal swab specimens from individuals suspected of respiratory viral infection consistent with COVID-19 and/or Flu by their healthcare provider within the first five days of the onset of symptoms in a Near Patient Testing setting, compared to Flu and SARS-CoV-2 RT-PCR tested using NP swab samples. Concordance analyisis of investigational device and reference method. Acceptance criterion: Sensitivity >80%, Specificity >95%

    Secondary Outcome Measures

    1. Secondary Outcome: [immediate]

      To assess the usability of the Panbio™ Rapid Panel when used by trained healthcare workers using a questionnaire.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    N/A and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Subjects from all age groups, able and willing to provide written informed consent or assent, suspected of having a respiratory viral infection consistent with COVID-19 and or Flu by their healthcare provider within the first five days of the onset of symptoms, and presenting at least two of the following symptoms: fever, headache, tiredness, dry cough, sore throat, runny or stuffy nose, muscle aches, loss of smell, loss of taste or shortness of breath, will be prospectively enrolled.
    Exclusion Criteria:
    • Subject has had a nasal or a NP swab taken within the last 4 hours and is not available for further testing after 4 hours has elapsed.

    • Subject has active nose bleeds or acute facial injuries/trauma.

    • Subject has received a nasal vaccine (i.e., FluMist®) within the previous fourteen (14) days.

    • Subject is currently taking or has taken an antiviral medication-e.g., Amantadine, Rimantadine, Relenza® (Zanamivir), Tamiflu® (Oseltamivir Phosphate), and Flumadine®-for influenza or COVID-19 within the previous thirty (30) days.

    • Subject is currently enrolled in a study to evaluate an investigational drug.

    • Subject is unwilling or unable to provide informed consent.

    • Vulnerable populations as deemed inappropriate for study by the site's PI and/or reviewing REC.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 UCCT @ Complete Health Partners- Nashville Nashville Tennessee United States 37209

    Sponsors and Collaborators

    • Abbott Rapid Dx

    Investigators

    None specified.

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Abbott Rapid Dx
    ClinicalTrials.gov Identifier:
    NCT05630365
    Other Study ID Numbers:
    • SDRD-H-027-P
    First Posted:
    Nov 29, 2022
    Last Update Posted:
    Dec 22, 2022
    Last Verified:
    Dec 1, 2022
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Dec 22, 2022