Genosvid Diagnostic Test for Early Detection of COVID-19

Sponsor
Gadjah Mada University (Other)
Overall Status
Completed
CT.gov ID
NCT04558372
Collaborator
(none)
1,999
8
3
8.4
249.9
29.8

Study Details

Study Description

Brief Summary

Electronic-nose had been used to diagnose other infectious lung diseases, such as tuberculosis. Universitas Gadjah Mada has developed an electronic-nose device which is easy-to-use, portable, and can be manufactured at a low price. Here the investigators test the electronic-nose to diagnose COVID-19 in Indonesia.

Condition or Disease Intervention/Treatment Phase
  • Other: exhaled breath sampling
  • Other: exhaled breath sampling
  • Other: exhaled breath sampling
N/A

Detailed Description

The validation of device is conducted to 43 confirmed COVID-19 patients and 40 confirmed COVID-19 negative patients from Bhayangkara Hospital, RSLKC Bambalipuro in Yogyakarta Special Region, Indonesia.

Afterwards, patients with symptoms suggesting COVID-19 will be recruited using multicentre consecutive sampling. The minimum number of participants required is 1460 subjects. The study use a triple-blind design where the research subjects, breath sample takers, and sample examiners did not know the results of each sampling that had been done. The final data processor was also blinded to the results of nose and throat swabs. The breath sampling data is saved in graphic form which interpretation will be carried out later by the data processor at the final stage.

This study population involve children and adults who come to the COVID-19 outpatient clinic in each participating hospital with a diagnosis of suspected COVID-19 infection. All patients remain in the setting under medical service in accordance with the standard operating procedure (SOP) and clinical practice guidelines (CPG) protocols for handling patients with suspected COVID-19. The patients underwent nasal and oropharyngeal swabs according to the COVID-19 outpatient CPG.

The participants will be asked about symptoms that they have, such as fever, fatigue, dry cough, stuffy/ runny nose, sore throat, myalgia, shortness of breath, and diarrhea. Afterwards, they will be asked to breathe normally using a mask for 2 times, then inhale and exhale in a forced expiratory volume to an air collecting bag that later is connected to the e-nose machine via a HEPA-filter. The performance of breath test will be compared with the performance of symptoms with the reference of RT-PCR results. In addition, participants' demographic and clinical data will be collected.

Study Design

Study Type:
Interventional
Actual Enrollment :
1999 participants
Allocation:
Non-Randomized
Intervention Model:
Single Group Assignment
Intervention Model Description:
3 groups: COVID-19 patients non COVID-19 patients suspected COVID-19 patients3 groups: COVID-19 patients non COVID-19 patients suspected COVID-19 patients
Masking:
Triple (Participant, Investigator, Outcomes Assessor)
Masking Description:
The person who operates breath test is blinded to the results of swab. The swab taker is blinded to the result of breath sample. The patients also do not know the results of the interpretation of the breath sample. Patients will receive information on the results of the oro/ nasopharyngeal swab in accordance with the COVID-19 health service standards. The final data processor is also blinded to the results of nose and throat swabs. The breath sampling data is saved in graphic form which interpretation will be carried out later by the data processor at the final stage.
Primary Purpose:
Diagnostic
Official Title:
Genosvid Diagnostic Test for Early Detection of COVID-19: UGM Electronic-Nose Innovation for Indonesia
Actual Study Start Date :
Apr 1, 2020
Actual Primary Completion Date :
Dec 12, 2020
Actual Study Completion Date :
Dec 12, 2020

Arms and Interventions

Arm Intervention/Treatment
Experimental: Group 1- 43 COVID-19 patients

COVID-19 patients breath normally via disposable non-rebreathing mask

Other: exhaled breath sampling
The participants breath through non-rebreathing mask until the reservoir bag is full. The reservoir bag is connected to Hepa-filter at one side, and another side of Hepa-filter is connected to the electronic-nose (Genosvid) device.
Other Names:
  • GENOSVID portable exhaled breath sampling
  • Experimental: Group 2- 40 non COVID-19 patients

    Non COVID-19 patients breath normally via disposable non-rebreathing mask

    Other: exhaled breath sampling
    The participants breath through non-rebreathing mask until the reservoir bag is full. The reservoir bag is connected to Hepa-filter at one side, and another side of Hepa-filter is connected to the electronic-nose (Genosvid) device.
    Other Names:
  • GENOSVID portable exhaled breath sampling
  • Experimental: Group 3- suspected COVID-19 patients

    The participants breath normally using a mask for 2 times then they are asked to inhale and exhale in a forced expiratory volume through an e-nose tube connected to the Hepa-filter at the inlet.

    Other: exhaled breath sampling
    The participants breath normally using a mask for 2 times then they are asked to inhale and exhale in a forced expiratory volume through an e-nose tube connected to the Hepa-filter at the inlet.
    Other Names:
  • GENOSVID portable exhaled breath sampling
  • Outcome Measures

    Primary Outcome Measures

    1. Diagnostic accuracy of electronic nose signal in COVID-19 [2 years]

      sensitivity, specificity, positive predictive value, negative predictive value of electronic nose signal in diagnosing COVID-19

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    4 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Patients diagnosed with COVID-19, non COVID-19, and suspected COVID-19 infection, based on the results of anamnesis, physical examination, laboratory, X-rays and rapid tests.

    • Able to produce samples for RT-PCR examination.

    • Agree to participate (sign informed consent). For children, informed consent are obtained from the parents. For adolescent patients, accent consent is asked.

    • Patients who do not need oxygen therapy supplementation in the form of mask-type or ventilator. Patients who use oxygen supplementation with nasal cannula are still included as study participants.

    Exclusion Criteria:
    • Unable to breath deeply due to difficulty breathing due to complications of COVID-19 or other diseases

    • The quality of the breath do not meet the standard interpretation of the instrument sensor curve (breath sampel is declared invalid).

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 RS Bhayangkara Tk I R.Said Soekanto Jakarta Indonesia
    2 Saiful Anwar Malang Indonesia
    3 Dr Sardjito Hospital Yogyakarta Indonesia 55281
    4 Bambanglipuro Hospital Yogyakarta Indonesia 55764
    5 Bhayangkara Tk III Polda DIY Yogyakarta Indonesia
    6 RS Akademik UGM Yogyakarta Indonesia
    7 RSPAU Hardjolukito Yogyakarta Indonesia
    8 RST Tk III Dr Soetarto Yogyakarta Indonesia

    Sponsors and Collaborators

    • Gadjah Mada University

    Investigators

    • Principal Investigator: Dian K. Nurputra, MD(Paed), M.Sc, Ph.D, Faculty of Medicine, Public Health and Nursing Universitas Gadjah Mada
    • Study Chair: Kuwat Triyana, Prof, Dr.Eng, MSi., Faculty of Mathematics and Natural Sciences Universitas Gadjah Mada

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    dr. Dian K. Nurputra, M.Sc, Ph.D, SpA, MD(Paed), M.Sc, Ph.D, Gadjah Mada University
    ClinicalTrials.gov Identifier:
    NCT04558372
    Other Study ID Numbers:
    • 1.6/2020
    First Posted:
    Sep 22, 2020
    Last Update Posted:
    Dec 29, 2020
    Last Verified:
    Dec 1, 2020
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by dr. Dian K. Nurputra, M.Sc, Ph.D, SpA, MD(Paed), M.Sc, Ph.D, Gadjah Mada University
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Dec 29, 2020