Comparison of Narrow and Regular Implants

Sponsor
T.C. Dumlupınar Üniversitesi (Other)
Overall Status
Completed
CT.gov ID
NCT04572490
Collaborator
(none)
51
1
4
12.6

Study Details

Study Description

Brief Summary

The study was designed as a retrospective, parallel, two years longitudinal pilot trial. Twenty-eight patients (mean age: 48.34 ± 6.06) aged between 35 and 60 years and 66 TiUnite surfaces (Nobel Biocare Parallel Conical Connection), bone level dental implant were included in the study. The implants were divided into two different groups according to the NPIs and regular platform implants(RPIs). The mean implant lengths, plaque index(PI), gingival index(GI), periodontal pocket depth(PD), gingival recession(GR), keratinized gingival width(KGW) and bleeding on probing(BOP) values were recorded. The Student's t-test used for between-group comparison.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: periapical radiograph

Detailed Description

Fifty-one participants and 123 dental implants were evaluated; twenty-three participants and 49 dental implants were excluded because of the different commercial brand dental implant (AstraTech, Straumann Roxolid, Bilimplant) and declining to participate. Seventy-four TiUnite dental implants were included in the study, but 8 TiUnite surface implants placed in the anterior region were excluded. Consequently, 15 male and 13 female patients and 66 dental implants were included in the study. This randomized retrospective clinical trial was designed according to the Consolidated Standards of Reporting Trials (CONSORT) Statement guidelines. A CONSORT Flow Chart of this study was shown in Figure 118.

The assignment was performed according to the dental implant diameters to include cases in the NPI and RPI which are the test and control groups. All dental implants involved are the Nobel Biocare Parallel CC brand (Nobel Biocare, Gothenburg, Sweden) with a TiUnite surface, and it defined a regular diameter of 4.3 mm and narrow diameter of 3.75 mm. Dental implants divided into two groups according to implant diameter, the NPI group comprised 3.75 mm diameter (NP, Ø= 3.75 mm) implants, and the RPI group comprised 4.3 mm diameter (RP, Ø= 4.3mm) implants (implant lengths: 10 mm-13 mm).

Clinical Measurements The clinical measurements were recorded at follow-up sessions using a periodontal probe that was calibrated in 1 mm increments. The clinical measurements were as follows: 1) plaque index (PI); 2) gingival index (GI); 3) probing depth (PD), the distance between the gingival margin and the bottom of a pocket; 4) clinical attachment level (CAL); the distance from the neck of the implant and the bottom of the pocket; 5) bleeding on probing (BOP); 6) keratinized gingival width (KGW), the height of peri-implant keratinized mucosa; 7) gingival recession (GR), the distance between the neck of the implant and the gingival margin. The same researcher performed all clinical measurements. A calibration protocol was applied to the reliability of measurements. PI, GI, PD, CAL, GR, KGW meaurements on five patients and ten peri-implant values were assessed. Calibration was accepted when measurements were 90% similar20. All clinical measurements were recorded for four sites (mesiobuccal, distobuccal, mid-buccal, mesiopalatal, midpalatal, and distopalatal) per peri-implant region. PD and PI measurements are reliable in peri-implantitis diagnosis21.

Prosthetic complications of patients were also evaluated clinically. Veneer ceramic chipping, abutment screw loosening or fracture, implant fracture, loss of retention were recorded.

Radiographic Measurements The studies have reported that periapical radiographs taken with the parallel technique are reliable in determining the MBL changes at different follow-ups. Digital periapical radiographs of the posterior region were obtained using a parallel method at follow-up sessions. MBL measurements were provided on periapical radiographs by a software program (Mediadent Software, The Dental Imaging Company, London, England). Ten radiographic MBL measurements around peri-implant were performed twice with an interval of 3 weeks, and researcher calibration was accepted when measurements were similar as %90. MBL was measured separately from the mesial and distal parts and also which the average of the two measurements. The reference points for the assessments are the implant shoulder and the most apical end-point of the bone-implant contact point. The vertical length between these two points is defined as MBL.

Study Design

Study Type:
Observational [Patient Registry]
Actual Enrollment :
51 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
The Comparison of Narrow and Regular Platform Dental Implants Placed Posterior Regions
Actual Study Start Date :
Jun 27, 2019
Actual Primary Completion Date :
Aug 31, 2019
Actual Study Completion Date :
Oct 28, 2019

Arms and Interventions

Arm Intervention/Treatment
Narrow platform implant

All measurements will be obtained after dental implant functional loading. Periodontal index will be recorded and alveolar bone loss measurements will be made on periapical radiographs.

Diagnostic Test: periapical radiograph
alveolar bone loss measurement on standardized parallel periapical radiograph

Regular platform implants

All measurements will be obtained after dental implant functional loading. Periodontal index will be recorded and alveolar bone loss measurements will be made on periapical radiographs.

Diagnostic Test: periapical radiograph
alveolar bone loss measurement on standardized parallel periapical radiograph

Outcome Measures

Primary Outcome Measures

  1. Marginal bone loss [change from baseline marginal bone loss at postoperatively 24. month]

    Peri-implant alveolar bone loss measurements on software program

Secondary Outcome Measures

  1. Keratinized gingival width [change from baseline peri-implant keratinized gingival width at postoperatively 24. month]

    Peri-implant keratinized gingival width measurements with clinically

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 90 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • the presence of a dental implant treated with fixed prosthetic restoration placed in the posterior jaw followed for at least one year after functional loading,

  • no active periodontal disease,

  • no history of penicillin allergy -

  • no radiotherapy to the head and neck region

  • smoking less than ten cigarettes per day,

  • no bone augmentation surgery before or during dental implant surgery,

  • aged over 18,

  • mesial or distal additional crown restoration was not performed,

  • no use of medications that affect bone metabolism and

  • not pregnant or lactating.

Exclusion Criteria:
  • the implants placed in the anterior region,

  • immediate placing and loading

  • augmented before or using a graft membrane with surgery

Contacts and Locations

Locations

Site City State Country Postal Code
1 Kütahya Health Sciences University Faculty of Dentistry Kütahya Turkey 43100

Sponsors and Collaborators

  • T.C. Dumlupınar Üniversitesi

Investigators

  • Principal Investigator: Berceste Guler, PhD, Kütahya Health Sciences University

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Berceste Guler, Assist Prof, T.C. Dumlupınar Üniversitesi
ClinicalTrials.gov Identifier:
NCT04572490
Other Study ID Numbers:
  • 2019/07-4
First Posted:
Oct 1, 2020
Last Update Posted:
Oct 1, 2020
Last Verified:
Sep 1, 2020
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Berceste Guler, Assist Prof, T.C. Dumlupınar Üniversitesi
Additional relevant MeSH terms:

Study Results

No Results Posted as of Oct 1, 2020