Brief Summary

This project will evaluate the effects of intramuscular diaphragm stimulation (pacing) and test the hypothesis that diaphragm pacing enhances neuromuscular diaphragm activation and respiratory function in adults with cervical spinal cord injuries (C-SCIs). The investigators will test the hypothesis by recording activity of the diaphragm from intramuscular pacing electrodes and conduct respiratory assessments in adults with intramuscular diaphragm pacing electrodes following acute, traumatic C-SCIs.

Condition or Disease Intervention/Treatment Phase
  • Device: Diaphragm Pacing

Detailed Description

Respiratory dysfunction is a leading cause of death in individuals with spinal cord injuries (SCIs). Nearly one-quarter of all SCI cases involve injury to the upper spinal cord segments which impairs neural activation of the diaphragm muscle and compromises breathing. Although mechanical ventilation can be life-saving after cervical SCI (C-SCI), it also triggers rapid and profound diaphragm muscle atrophy, thereby complicating (or even preventing) ventilator weaning. Intramuscular diaphragm stimulation, or diaphragm pacing, was developed to replace long-term ventilator support and is now used acutely post C-SCI (<4 months following injury) to promote ventilator weaning. This study will assess the effects of diaphragm stimulation on respiratory neural drive and breathing function in individuals with acute, traumatic C-SCI. Recording from these surgically implanted electrodes allows comparisons of electromyogram (EMG) recordings, in association with respiratory assessments, before and after short periods of diaphragm pacing to isolate the unique contribution of diaphragm pacing on neuromuscular diaphragm activation.

Study Design

Study Type:
Observational
Anticipated Enrollment :
10 participants
Observational Model:
Case-Only
Time Perspective:
Prospective
Official Title:
Diaphragm Stimulation After Human Spinal Cord Injury: Effects on Respiratory Neural Drive and Function
Actual Study Start Date :
Jan 10, 2020
Anticipated Primary Completion Date :
Jul 31, 2022
Anticipated Study Completion Date :
Jul 31, 2022

Arms and Interventions

Arm Intervention/Treatment
Cervical SCI

Participants with acute, traumatic cervical spinal cord injuries (C-SCIs), classified according to the American Spinal Injury Association (ASIA) Impairment Scale (AIS) as A-C (complete SCI (A); motor complete SCI (B); motor incomplete with minimal motor function (C)), affecting C1-C6 spinal cord segments, and who have been scheduled to undergo implantation of a diaphragm pacer, or who have recently received (in past 5-days) implantation of intramuscular diaphragm pacing electrodes due to severe respiratory impairments and dependence on mechanical ventilation.

Device: Diaphragm Pacing
Intramuscular stimulation of the diaphragm, or diaphragm "pacing' is achieved by laparoscopic placement of stimulation wires into each hemidiaphragm. Phrenic motor points on the diaphragm are mapped to optimize electrode placement. The electrodes are threaded into the diaphragm muscle and wire leads are externalized and attached to a stimulation controller.

Outcome Measures

Primary Outcome Measures

  1. Change in Electromyogram (EMG) [Baseline up to 24 hours]

    Neuromuscular activation of the diaphragm will be assessed by recording diaphragm EMGs from the surgically-implanted intramuscular stimulating electrodes. This approach will allow for comparisons of EMG recordings across time. EMGs will be recorded during non-stimulated respiration (diaphragm pacer turned off) and simultaneously with assessments of respiratory function.

  2. Change in Maximal Inspiratory Pressure (MIP) [Baseline up to 24 hours]

    The Maximum Inspiratory Pressure (MIP) is measured by a device that applies an inspiratory load which provides a resistance. The MIP will be measured in cmH20 and assesses diaphragm strength. MIP will be recorded will be recorded during non-stimulated respiration (diaphragm pacer turned off).

  3. Change in Tidal Volume [Baseline up to 24 hours]

    The measurement of Tidal Volume is performed through a simple spirometry and is measured in liters. Tidal Volume will be recorded during non-stimulated respiration (diaphragm pacer turned off).

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 75 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Acute, traumatic cervical spinal cord injuries (C-SCIs), classified according to the American Spinal Injury Association (ASIA) Impairment Scale (AIS) as A-C

  • Scheduled to undergo implantation of a diaphragm pacer, or who have recently received (in past 5-days) implantation of intramuscular diaphragm pacing electrodes due to severe respiratory impairments and dependence on mechanical ventilation

Exclusion Criteria:
  • Progressive neuromuscular diseases such as multiple sclerosis and myasthenia gravis

  • History of neurologic injuries such as stroke or prior SCI

  • Chest wall injuries or deformities likely to influence breathing

  • Pregnancy

  • Cognitive impairments limiting study participation

Contacts and Locations

Locations

Site City State Country Postal Code
1 UF Health - Jacksonville Jacksonville Florida United States 32008

Sponsors and Collaborators

  • University of Florida
  • National Institutes of Health (NIH)

Investigators

  • Principal Investigator: Emily Fox, PT, PhD, University of Florida

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
University of Florida
ClinicalTrials.gov Identifier:
NCT04179799
Other Study ID Numbers:
  • IRB201902285
  • 1OT2OD023854
First Posted:
Nov 27, 2019
Last Update Posted:
Nov 5, 2021
Last Verified:
Nov 1, 2021
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by University of Florida