ACE-2: Safety And Performance Of Disc Care To Prevent Lumbar Disc Herniation Recurrence

Sponsor
NEOS Surgery (Industry)
Overall Status
Not yet recruiting
CT.gov ID
NCT06023719
Collaborator
(none)
30
1
36

Study Details

Study Description

Brief Summary

The goal of this clinical investigation is to learn about DISC Care, an Hernia Blocking System, in patients who have undergone lumbar disc hernia surgery. The main questions it aims to answer are:

  • if the implant (DISC Care) prevents disc herniation recurrence

  • if DISC Care is a safe device

Participants will be implanted with DISC Care and followed up for two years (7 visits).

Condition or Disease Intervention/Treatment Phase
  • Device: DISC Care
N/A

Study Design

Study Type:
Interventional
Anticipated Enrollment :
30 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Prevention
Official Title:
Multicentric Clinical Investigation To Assess The Safety And Performance Of Disc Care To Prevent Lumbar Disc Herniation Recurrence
Anticipated Study Start Date :
Sep 1, 2023
Anticipated Primary Completion Date :
Sep 1, 2026
Anticipated Study Completion Date :
Sep 1, 2026

Arms and Interventions

Arm Intervention/Treatment
Experimental: DISC Care

DISC Care implant

Device: DISC Care
Medical device to prevent disc herniation recurrence
Other Names:
  • Hernia Blocking System
  • Outcome Measures

    Primary Outcome Measures

    1. Incidence of clinically symptomatic recurrent lumbar disc herniation [24 months]

    Secondary Outcome Measures

    1. Incidence and type of all adverse events (AE) and serious adverse events (SAE). [6 weeks, 6 months, 12 months, and 24 months]

    2. Incidence of clinically asymptomatic recurrent disc herniation [6 months, 12 months, and 24 months]

    3. Incidence of re-interventions [6 weeks, 6 months, 12 months, and 24 months]

    4. Disc height maintenance [mm] related to baseline [6 months, 12 months, and 24 months]

    5. Change in leg and low back pain, related to baseline [6 weeks, 6 months, 12 months, and 24 months]

      0-10 NRS (numeric rating scale)

    6. Change in Low back related disability, related to baseline [6 weeks, 6 months, 12 months, and 24 months]

      Oswestry Disability Index (ODI)

    7. The change in quality of life, compared to baseline [6 weeks, 6 months, 12 months, and 24 months]

      EQ-5D-5L (5-level EQ-5D version)

    8. The change in patient neurological status, compared to baseline [6 weeks, 6 months, 12 months, and 24 months]

      straight leg raise test, reflexes, motor muscle strength and sensory neurological evaluations, classified as normal or abnormal

    9. The degeneration of the disc, in comparison with the preoperative state [6 months, 12 months, and 24 months]

      Pfirrmann intervertebral disc degeneration scale (I, II, III, IV, V)

    10. the direct and indirect costs of the disease and the intervention. [6 weeks, 6 months, 12 months, and 24 months]

      Custom-made questionnaire

    Other Outcome Measures

    1. Description of the impact of the procedure (implantation of the device) on the perioperative parameters [Surgery]

      Blood loss (mL)

    2. Description of the impact of the procedure (implantation of the device) on the perioperative parameters [Surgery]

      X-ray exposition (seconds of x-ray exposition)

    3. Description of the impact of the procedure (implantation of the device) on the perioperative parameters [Surgery]

      Surgery duration (minutes)

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 75 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Subject is between 18 and 75 years old.

    • Posterolateral disc hernia between levels L4 and S1 with radiological (CT scan or MRI) confirmation of neural compression.

    • At least six weeks of failed conservative treatment prior to surgery, including physical therapy, use of anti-inflammatory medications at maximum specified dosage and/or administration of epidural/facet injections.

    • Minimum posterior disc height of 5 mm at the index level.

    • Radiculopathy with positive straight leg raise test.

    • ODI score of at least 30/100.

    • Subjects who are able to give voluntary informed consent to participate in the clinical investigation and from whom consent has been obtained.

    • Subject is able and willing to comply with the protocol requirements.

    Exclusion Criteria:
    • Spondylolisthesis and/or instability at the index level that, in the judgement of the surgeon, could affect the device implantation.

    • Central, foraminal or extraforaminal disc hernia.

    • Subject has vertebral bodies of the index level affected by any traumatic, neoplastic, metabolic, or infectious pathology.

    • Subject has scoliosis of greater than 20 degrees (both angular and rotational).

    • Grossly distorted anatomy due to congenital abnormalities.

    • Deformation that affects the posterior corners of the vertebra at the index level (e.g., osteophytes) that, in the judgment of the surgeon, could affect the device implantation.

    • Endplate irregularities that, in the judgment of the surgeon, could affect the device implantation.

    • Prior surgery at the index lumbar vertebral level that, in the judgment of the surgeon, could affect the device implantation.

    • Radiological confirmation of severe facet joint disease or degeneration.

    • Patients diagnosed or at a high risk of osteoporosis (such as postmenopausal women and patients receiving long-term treatment with corticosteroids) who present a bone densitometry DXA (dual energy x-ray absorptiometry) T-score of less than -2.0 at the index level.

    • Cauda equina syndrome.

    • Fever, leucocytosis and/or systemic or localized active infection.

    • Systemic inflammation and/or inflammation at the implantation site.

    • Any uncontrolled metabolic bone disease that affects the spine.

    • Uncontrolled insulin-dependent diabetes mellitus.

    • Peripheral neuropathy.

    • Active hepatitis, AIDS or HIV.

    • Rheumatoid arthritis or other autoimmune disease that affects the spine joints.

    • Active or history of any invasive malignancy; patients with curatively-treated malignancies who have been disease-free for at least 5 years are eligible.

    • Uncontrolled active tuberculosis or history of uncontrolled tuberculosis in the past 3 years.

    • Immunologically suppressed patients.

    • Current anticoagulation therapy, unless anticoagulation therapy can be suspended for surgery.

    • Patients who have received medication (e.g., methotrexate, alendronate) that interferes with bone mineral metabolism within 4 weeks of the planned date of the index surgery.

    • Suspected or known allergies or intolerance to the device materials: titanium, nitinol, stainless steel, polyetheretherketone and polyethylene terephthalate.

    • Any condition that precludes the use of general anaesthesia.

    • Any condition that precludes the surgical procedure.

    • Any contraindication for MRI or CT scan.

    • Class III obesity: Body mass index ≥ 40.

    • Current alcohol or recreational drug dependency.

    • Pregnant or interested in becoming pregnant in the following 24 months.

    • Breastfeeding.

    • Life expectancy less than 2 years.

    • Subject is currently participating or has participated in the previous 4 weeks in any other interventional clinical study.

    Contacts and Locations

    Locations

    No locations specified.

    Sponsors and Collaborators

    • NEOS Surgery

    Investigators

    None specified.

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    NEOS Surgery
    ClinicalTrials.gov Identifier:
    NCT06023719
    Other Study ID Numbers:
    • NEO-RA1-2023-01
    First Posted:
    Sep 5, 2023
    Last Update Posted:
    Sep 5, 2023
    Last Verified:
    Sep 1, 2023
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Sep 5, 2023