Dynamic Light Scattering for Studying Lens Aging and Cataract Formation

Sponsor
National Eye Institute (NEI) (NIH)
Overall Status
Completed
CT.gov ID
NCT00081991
Collaborator
(none)
267
1
12
22.3

Study Details

Study Description

Brief Summary

This study will use dynamic light scattering (DLS) technology to study normal lens aging and early cataract formation. Cataract is a clouding of the lens that interferes with the passage of light to the retina, impairing visual acuity. DLS uses a low intensity laser light (similar to that used in supermarket checkouts) to measure lens cloudiness. It detects changes in the human lens at the earliest molecular stages of cataract development, when anti-cataract treatment would be most effective in reversing, delaying or preventing cataract formation.

Healthy normal volunteers and patients with age-related cataract between 18 and 80 years of age may be eligible for this study. Participants undergo the following tests and procedures:

Medical history

Eye examination, including the following:
  • Measurement of visual acuity (vision chart)

  • Measurement of eye pressure

  • Dilation of the pupils for slit lamp (microscope) examination and grading of lens opacity

  • Ultrasound examination of the eye to determine distances between cornea, lens (including lens thickness), and retina

  • Examination of the retina at the back of the eye

  • Dynamic light scattering of the lens (see below)

  • Lens photography using a camera with a bright flash

For the DLS procedure, the patient sits in front of the DLS device with his or her chin placed on a chin rest and fixes on a yellow target in the center of the camera lens. When the eye is properly aligned, DLS measurements are taken on the lens.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    A new non invasive, in vivo technique to study the molecular changes in the human lens, called Dynamic Light Scattering Device (DLS), has recently been developed. Preliminary studies have shown its potential to detect the earliest changes in cataract, at the stage where anti-cataract treatment would be most effective in reversing, delaying or preventing cataracts. A new miniaturized version of this device has been developed by NASA using lower energy lasers, and under a NASA-NEI Inter Agency Agreement, has been successfully developed into a clinical device at the NEI. We recently conducted pilot studies to evaluate the usefulness and reproducibility of this instrument for quantitating human lens changes, and found good reproducibility. We also derived a useful parameter to use with this new technique, the log mean particle size, derived from particle size distribution data. Preliminary studies have also shown that the NASA-NEI DLS device can be used to detect and monitor molecular changes in early cataract formation as well as in normal aging. We therefore propose to conduct a larger cross sectional clinical study to detect and monitor molecular changes in the lens in early cataract formation and in normal aging.

    Study Design

    Study Type:
    Observational
    Official Title:
    A Cross Sectional Clinical Study of Human Lens Aging and Cataract Formation, in Vivo, Using Dynamic Light Scattering (DLS)
    Study Start Date :
    Apr 1, 2004
    Study Completion Date :
    Apr 1, 2005

    Outcome Measures

    Primary Outcome Measures

      Eligibility Criteria

      Criteria

      Ages Eligible for Study:
      N/A and Older
      Sexes Eligible for Study:
      All
      Accepts Healthy Volunteers:
      Yes
      INCLUSION CRITERIA:

      Patients aged 18-80 years will be admitted to this study. There will be no racial or gender bias in the recruitment.

      227 patients with AREDS nuclear cataract grades 2 or less will be enrolled in the study. 40 patients with AREDS nuclear cataract grade 3 and 4 will also be enrolled.

      For those patients enrolled in the study, both eyes will be evaluated for this protocol. However, the participant has the right to choose to undergo measurements only in one eye. In that case, the eye to be examined will be determined by the partipantt's birth month. If the patient's birth month is an even number, the right eye will be examined; if the patient's birth month is odd, the left eye will be examined.

      EXCLUSION CRITERIA:

      Subjects who have tear film disorders, corneal opacities or disorders, uveitis, glaucoma or who have difficulty fixating, will be excluded.

      Subjects who are thought to be at risk for an adverse reaction to pupil dilation, or have a history of allergic reaction to one of the dilating agents that will be used, will be excluded.

      Contacts and Locations

      Locations

      Site City State Country Postal Code
      1 National Eye Institute (NEI) Bethesda Maryland United States 20892

      Sponsors and Collaborators

      • National Eye Institute (NEI)

      Investigators

      None specified.

      Study Documents (Full-Text)

      None provided.

      More Information

      Publications

      Responsible Party:
      , ,
      ClinicalTrials.gov Identifier:
      NCT00081991
      Other Study ID Numbers:
      • 040166
      • 04-EI-0166
      First Posted:
      Apr 28, 2004
      Last Update Posted:
      Mar 4, 2008
      Last Verified:
      Apr 1, 2005

      Study Results

      No Results Posted as of Mar 4, 2008