EGO-COMBO Clinical End-point Extension Study Beyond 36 Months

Sponsor
The University of Hong Kong (Other)
Overall Status
Completed
CT.gov ID
NCT02263313
Collaborator
(none)
59
1

Study Details

Study Description

Brief Summary

In this study, the safety and efficacy of COMBO TM stent beyond 36 months are assessed, in particular the occurrence of late stent thrombosis and late loss catch-up (restenosis).

Condition or Disease Intervention/Treatment Phase
  • Other: EGO-COMBO group

Detailed Description

The Genous Stent (the EPC Capture R-stent, OrbusNeich Medical Inc., Fort Lauderdale, FL) is commercially available and has been used extensively in standard coronary intervention in the treatment of more than 200 patients with critical coronary stenoses at Queen Mary Hospital. The COMBO Stent (OrbusNeich Medical Inc., Fort Lauderdale, FL) is an improved version of the Genous Stent and is now widely available for clinical use in all Hong Kong hospitals. To date, more than 300 patients in Queen Mary Hospital have received the COMBO stent as treatment for their coronary artery disease, and all of them remained stable clinically.

The Genous Stent is a bio-engineered 316L stainless steel coronary stent with a biocompatible coating having specific CD34 antibody on the inner surface. CD34 is a surface antigen present on circulating endothelial progenitor cell (EPC). It will be bonded to the CD34 antibody, resulting in capturing of the EPC onto the stent surface and differentiation into endothelial layer. Animal model has demonstrated that a functional endothelial layer could be formed as soon as 24 to 48 hours after Genous stent implantation (1). The HEALING-FIM registry has shown that Genous stent is clinically safe and effective in the treatment of coronary stenosis (2). Recent reports have further confirmed its efficacy in patients with acute coronary syndrome requiring urgent revascularization (3,4).

The COMBO Stent is an improved version of the Genous Stent. The stent delivers a drug called sirolimus to the treated coronary blood vessel. This stent also incorporates a CD34 antibody coating that is designed to promote the healing of the treated coronary artery by catching endothelial progenitor cells from circulating blood as they pass through the stent. These cells are pro-healing and will help the blood vessel wall to heal over the stent more quickly and restore normal tissue function in the stented area. The combination of these two technologies in this new Combo stent is expected to produce even better clinical results, which are published in the REMEDEE Study.

Pre-clinical animal study has already shown the Combo Stent promoted endothelialization and reduced neointima formation, as assessed by both optical coherence tomography (OCT) and histopathology (5). However, such beneficial endothelial coverage as assessed by OCT has never been documented in human subjects, and has been addressed by previous study protocol: the EGO Study (IRB: UW 10-256), EGO-COMBO Pilot Study (UW 10-342) and EGO-COMBO angiographic extension study (UW 12-472). Queen Mary Hospital is currently the single cardiac centre worldwide with such vast experience in using the COMBO stent for percutaneous coronary intervention, together with intracoronary OCT to profile the stent's healing progress and subsequent neo-intimal growth and behaviour.

This current study protocol serves as an extension study to evaluate the long term clinical safety and efficacy of COMBO stent beyond 36 months post-implantation.

This is a single centre observational study to assess the safety and effectiveness clinical endpoints of COMBO TM stent beyond 36 months. Clinical notes for all subjects that previously participated in EGO-COMBO Pilot Study (UW 10-342) will be reviewed for clinical end points according to the definition of Academic Research Consortium and angina symptoms will be classified with Canadian Cardiovascular Society Angina Classification.

Study Design

Study Type:
Observational
Actual Enrollment :
59 participants
Observational Model:
Cohort
Time Perspective:
Retrospective
Official Title:
Evaluation of Endothelial ProGenitor Cell Capture Sirolimus-Eluting Stent by Optical Coherence Tomography: the COMBO Stent 36-months Clinical End-point Extension Study (EGO-COMBO Clinical End-point Extension Study Beyond 36 Months)
Study Start Date :
Sep 1, 2014
Actual Primary Completion Date :
Sep 1, 2014
Actual Study Completion Date :
Sep 1, 2014

Arms and Interventions

Arm Intervention/Treatment
EGO-COMBO group

Previously enrolled into EGO-COMBO Pilot study and with combo stent

Other: EGO-COMBO group
Assess the safety and effectiveness of Combo stent

Outcome Measures

Primary Outcome Measures

  1. Composite Major Adverse Cardiac Events (MACE) [beyond 36 months]

Secondary Outcome Measures

  1. All-cause mortality [beyond 36 months]

  2. Myocardial infarction [beyond 36 months]

  3. Target Lesion Revascularization [beyond 36 months]

  4. Angina Class [beyond 36 months]

  5. Target Vessel Failure [beyond 36 months]

  6. Cardiac Death [beyond 36 months]

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Patient previously participated in EGO-COMBO Pilot Study (UW 10-342)
Exclusion Criteria:
  • Patient not previously participated in EGO-COMBO Pilot Study (UW 10-342)

Contacts and Locations

Locations

Site City State Country Postal Code
1 Department of Medicine, Queen Mary Hospital, The University of Hong Kong Hong Kong Hong Kong China

Sponsors and Collaborators

  • The University of Hong Kong

Investigators

  • Principal Investigator: Wai Luen Stephen LEE, MD, The Univeristy of Hong Kong

Study Documents (Full-Text)

None provided.

More Information

Additional Information:

Publications

None provided.
Responsible Party:
Prof. Stephen Lee, Professor and Chief, The University of Hong Kong
ClinicalTrials.gov Identifier:
NCT02263313
Other Study ID Numbers:
  • UW 14-456 (IRB HKU)
First Posted:
Oct 13, 2014
Last Update Posted:
Oct 13, 2014
Last Verified:
Oct 1, 2014
Keywords provided by Prof. Stephen Lee, Professor and Chief, The University of Hong Kong
Additional relevant MeSH terms:

Study Results

No Results Posted as of Oct 13, 2014