Human Factors Validation Testing for the Peripal System; a Manual Connection Assist Device for Peritoneal Dialysis Devices

Sponsor
Peripal AG (Industry)
Overall Status
Completed
CT.gov ID
NCT04292210
Collaborator
Swiss Federal Institute of Technology (Other), University Hospital Birmingham NHS Foundation Trust (Other)
24
1
1
2.3
10.4

Study Details

Study Description

Brief Summary

It is estimated that there are currently over 3 million patients receiving dialysis treatment worldwide. With effective pre-dialysis counselling, a majority of patients choose the home-based therapy peritoneal dialysis (PD) but only approximately 11% of prevalent dialysis patients use this modality. Connection-assist devices can overcome the challenges posed by decreased manual dexterity and/or visual acuity, and can allow more patients to be treated with home-based therapies. As part of the CE marking authorization, a connection device has been evaluated for safety and ease of use in a usability study.

Detailed Description

The growth in the renal replacement therapy population is primaryly in the elderly age group, a population with a high frailty and comorbidity burden. Facilitating PD in this group of patients requires improved PD technology with greater accessibility tailored to patient needs. Following evaluation of specific barriers to the use of PD including feedback from established PD patients, a novel connection-assist device has been developed.

As part of the CE marking authorization, the connection device has been evaluated for safety and ease of use in a study at University Hospitals Birmingham NHS Foundation Trust involving 24 patients and carers.

The evaluated device is designed to assist peritoneal dialysis patients performing their daily dialysis treatment either for APD or for CAPD. The device facilitates the connection and disconnection of the dialysis line to the PD catheter transfer set. The connections are performed inside the device in a protected area, and the patient does not need to touch the transfer set or the dialysis line while they are unprotected. In addition, the breaking of the dialysis line frangible and the clamping of the dialysis line are replaced by pushing a button.

The operating procedure of the device consists of multiple tasks including preparing and loading the transfer set and dialysis line into the device, performing the handling steps related to the PD therapy with the device and finally unloading the used material from the device. Each task comprises several handling steps. During the study, the operating procedure with the device was simulated and the subjects were connected to a dummy catheter, which was attached to an apron.

This study recruited established PD patients and carers involved in the delivery of PD. Carers included healthcare professionals and lay carers.

The study design was divided into three one hour long parts. Firstly, a training session introduced the operation of the device. Secondly, a break of one hour allowed relaxation and recovery. Thirdly, a test was carried out to determine whether the subject could use the device independently with the aid of a quick start guide and the device manual.

The training consisted of two cycles in which the moderator guided the subject and three cycles in which the subject guided the moderator through the complete handling of the device. After the break, the subjects were asked to carry out a complete handling cycle themselves. Subjects could use the quick start guide and the device manual as help. After the unsupported handling cycle, subjects were asked to complete the NASA Task Load Index (N-TLX) questionnaire. In the meantime, the moderator left the room to obtain information on observed use errors. In a final semi-structured interview, the subjects were asked about the reasons for the observed use errors.

For each subject, one moderator and one observer were involved in the study. The moderator was the interface between the subject and the device both in training and in testing. This person was employed by an external agency to avoid any influence on the subject. The observer saw the handling with the help of a live feed from a separate room. He evaluated the handling steps in the categories of "safe use" and "use error" according to IEC 62366-1. For each use error, the observer described the observed situation from his point of view. In addition to evaluating the effectiveness of the task performance, the subjects were interviewed in a semi structured way. Here the observations of technique errors were discussed with the subjects in order to identify the specific causes. In this interview, the subjects were also asked for their feedback on the general ease of use of the device.

In addition, the subjects were asked about the task load in six different dimensions in the standardized N-TLX. Task load is a hypothetical construct that represents the cost incurred by a human operator to achieve a particular level of performance. The dimensions of the N-TLX are mental, physical and temporal demands as well as performance, effort and frustration in the task. Each dimension is evaluated on a 20-point scale. This scale is then transferred to the task load index, which is a scale between 0 and 100 points. To classify the results of the N-TLX, Eitrheim and Fernandes (2016) state "Workload levels below 50 were perceived as acceptable."

Study Design

Study Type:
Interventional
Actual Enrollment :
24 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Intervention Model Description:
The growth in the RRT population is primary in the elderly age group, a population with a high frailty and comorbidity burden. Facilitating PD in this group of patients requires improved PD technology with greater accessibility tailored to patient needs. It is proposed that by making PD treatment simpler, more standardized and better protected from infections, patient access to PD could be increased significantly. Following evaluation of specific barriers to the use of PD including feedback from established PD patients, a novel connection-assist device has been developed. As part of the CE marking authorization, the connection device has been evaluated for safety and ease of use in a study at University Hospitals Birmingham NHS Foundation Trust involving 24 patients and carers.The growth in the RRT population is primary in the elderly age group, a population with a high frailty and comorbidity burden. Facilitating PD in this group of patients requires improved PD technology with greater accessibility tailored to patient needs. It is proposed that by making PD treatment simpler, more standardized and better protected from infections, patient access to PD could be increased significantly. Following evaluation of specific barriers to the use of PD including feedback from established PD patients, a novel connection-assist device has been developed. As part of the CE marking authorization, the connection device has been evaluated for safety and ease of use in a study at University Hospitals Birmingham NHS Foundation Trust involving 24 patients and carers.
Masking:
None (Open Label)
Masking Description:
The training consisted of two cycles in which the moderator guided the subject and three cycles in which the subject guided the moderator through the complete handling of the device. For each subject, one moderator and one observer were involved in the study. The moderator was the interface between the subject and the device both in training and in testing. This person was employed by an external agency to avoid any influence on the subject. The observer saw the handling with the help of a live feed from a separate room. He evaluated the handling steps in the categories of "safe use" and "use error" according to IEC 62366-1 (2015). For each use error, the observer described the observed situation from his point of view.
Primary Purpose:
Other
Official Title:
Evaluating Patient Safety And Ease Of Use Of A Novel Connection-Assist Device For Peritoneal Dialysis
Actual Study Start Date :
Feb 19, 2018
Actual Primary Completion Date :
Mar 12, 2018
Actual Study Completion Date :
Apr 30, 2018

Arms and Interventions

Arm Intervention/Treatment
Experimental: CAPD handling

A connecting device simplifying the steps during a cycle of Peritoneal dialysis. Instead of directly doing a manual connection and manually breaking a frangible, the device assist in connecting and breaking the frangible. This study was done demonstrating a continuous ambulatory peritoneal dialysis (CAPD)

Device: Perisafe
A medical device simplifying the connection of tubing as well as breaking of the frangible which is done in a sterile environment with the help of levers and buttons.

Outcome Measures

Primary Outcome Measures

  1. Safety and ease of use of a connection device during a continuous ambulatory peritoneal dialysis [3 hours]

    Firstly, a training session introduced the operation of the device. The normal steps of a manual connection and breaking of the frangible is replaced by the levers and the buttons in the device. The connections are thereby done in a 'safe' environment which reduces infection risk. A whole cycle of continuous ambulatory peritoneal dialysis is simulated during each training. Secondly, a break of one hour allowed relaxation and recovery. Thirdly, a test was carried out to determine whether the subject could use the device independently with the aid of a quick start guide and the device manual. The training consisted of two cycles in which the moderator guided the subject and three cycles in which the subject guided the moderator through the complete handling of the device. Each of the 24 subjects performed 52 handling steps resulting in a total of 1248 evaluated handling steps.

  2. Nasa Task Load Index (N-TLX) [3 hours]

    The operating procedure of the device consists of multiple tasks comprising several handling steps. the subjects were asked about the task load in six different dimensions in the standardized N-TLX. Task load is a hypothetical construct that represents the cost incurred by a human operator to achieve a particular level of performance. The dimensions of the N-TLX are mental, physical and temporal demands as well as performance, effort and frustration in the task. Each dimension is evaluated on a 20-point scale. This scale is then transferred to the task load index, which is a scale between 0 and 100 points. Workload levels below 50 were perceived as acceptable.

  3. Observation of technique [3 hours.]

    Here the observations of technique errors were discussed with the subjects in order to identify the specific causes. In this interview, the subjects were also asked for their feedback on the general ease of use of the device.

Eligibility Criteria

Criteria

Ages Eligible for Study:
N/A and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes

Fifteen patients and nine carers volunteered in this study, ranging from 23 to 86 years in age and from 0.3 to 24 years in experience in the PD therapy.

Contacts and Locations

Locations

Site City State Country Postal Code
1 NIHR Trauma Management MedTech Co-operative Birmingham United Kingdom

Sponsors and Collaborators

  • Peripal AG
  • Swiss Federal Institute of Technology
  • University Hospital Birmingham NHS Foundation Trust

Investigators

  • Study Chair: Lukas Foggensteiner, MD, PhD, National Health Service, United Kingdom
  • Study Chair: Mirko Meboldt, PhD, ETH
  • Study Chair: Martin Dubach, Peripal AG
  • Principal Investigator: Stephan Hess, ETH

Study Documents (Full-Text)

None provided.

More Information

Additional Information:

Publications

None provided.
Responsible Party:
Peripal AG
ClinicalTrials.gov Identifier:
NCT04292210
Other Study ID Numbers:
  • IRAS ID :235715
First Posted:
Mar 3, 2020
Last Update Posted:
Mar 3, 2020
Last Verified:
Feb 1, 2020
Individual Participant Data (IPD) Sharing Statement:
Undecided
Plan to Share IPD:
Undecided
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Peripal AG
Additional relevant MeSH terms:

Study Results

No Results Posted as of Mar 3, 2020