Direct Anterior vs. Anterolateral Approach for Hip Arthroplasty After Femoral Neck Fracture in the Senior Population

Sponsor
Mayo Clinic (Other)
Overall Status
Active, not recruiting
CT.gov ID
NCT02959320
Collaborator
(none)
68
1
2
73
0.9

Study Details

Study Description

Brief Summary

Displaced femoral neck fractures are one group of hip fracture patients that are commonly treated with cemented hemiarthroplasty (HA) or total hip arthroplasty (THA). In the elective hip arthroplasty population, the direct anterior approach (DAA) has shown to be effective in helping patients to quickly obtain high postoperative function. This approach has also been shown to be effective in arthroplasty for displaced femoral neck fractures in a few studies. However, the only studies that directly compare two approaches for hip arthroplasty for femoral neck fractures utilize the anterolateral approach (ALA) versus posterior approach (PA) or DAA versus PA. No studies of which we are aware directly compare the DAA to the ALA. The DAA and ALA are the two most popular approaches for bipolar hemiarthroplasty at our institution, so we are setting out to determine the differences between them.

Condition or Disease Intervention/Treatment Phase
  • Procedure: Hip Hemiarthroplasty
N/A

Detailed Description

Displaced femoral neck fractures are one group of hip fracture patients that are commonly treated with cemented hemiarthroplasty (HA) or total hip arthroplasty (THA). Compared to those who receive a THA, recipients of HA tend to be less active, more debilitated, and more dependent on gait aids and the care of others. In this population, the increased stability and decreased operating time associated with HA is thought to be more important than the minimal increase in function this population could achieve with THA. Additionally, cemented femoral stems in HA are thought to result in less pain, increased function, and less periprosthetic fracture risk when compared to cementless stems.

With the relative pre-injury debility of the femoral neck fracture population, especially those receiving HA, it is important to optimize all aspects of patient care to allow them to participate in therapy and return them to their preoperative functional level as quickly as possible. Furthermore, any intervention in this population should minimize the physiologic insult of surgery as much as possible. In the elective hip arthroplasty population, the direct anterior approach (DAA) has shown to be effective in helping patients to quickly obtain high postoperative function. This approach has also been shown to be effective in arthroplasty for displaced femoral neck fractures in a few studies. However, the only studies that directly compare two approaches for hip arthroplasty for femoral neck fractures utilize the anterolateral approach (ALA) versus posterior approach (PA) or DAA versus PA. No studies of which we are aware directly compare the DAA to the ALA. The DAA and ALA are the two most popular approaches for bipolar hemiarthroplasty at our institution, so investigators are setting out to determine the differences between them.

Study Design

Study Type:
Interventional
Actual Enrollment :
68 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
A Randomized Clinical Trial of Direct Anterior vs. Anterolateral Approach for Hip Arthroplasty After Femoral Neck Fracture in the Senior Population
Study Start Date :
Nov 1, 2016
Actual Primary Completion Date :
Mar 1, 2022
Anticipated Study Completion Date :
Dec 1, 2022

Arms and Interventions

Arm Intervention/Treatment
Active Comparator: Direct Anterior Approach

All patients receiving a hip hemiarthroplasty through a Direct Anterior Approach (DAA) will have their surgeries performed with the aid of fluoroscopy on an OSI Hana table that allows the operative limb to be manipulated through range of motion and traction while keeping the pelvis stabilized. This table also has a radiolucent platform about the pelvis, enabling the surgery to be fluoroscopically assisted. The incision for the DAA will extend from a proximal point about 2 cm distal and 2 cm lateral to the ASIS to a point 8-12 cm distal and slightly lateral to this.

Procedure: Hip Hemiarthroplasty
This single-institution, prospective, randomized clinical trial will be performed on consecutive elderly patients admitted for surgical treatment of displaced femoral neck fractures with hemiarthroplasty (HA).

Active Comparator: Anterolateral Approach

All patients receiving a hip hemiarthroplasty through an the Anterolateral Approach (ALA) will have their surgeries performed on a standard OR table in a contralateral lateral decubitus position. With the leg in the position of sleep, a straight 8-12 cm incision will be made, centered over the greater trochanter and femoral shaft with 1/3 of the incision extending superior to the tip of the greater trochanter.

Procedure: Hip Hemiarthroplasty
This single-institution, prospective, randomized clinical trial will be performed on consecutive elderly patients admitted for surgical treatment of displaced femoral neck fractures with hemiarthroplasty (HA).

Outcome Measures

Primary Outcome Measures

  1. Number of patients showing improvement using the Timed Up and Go (TUG) Test [Baseline to 12 months]

    Purpose of test is to assess mobility and will be administered by a nurse who is blinded to the surgical approach.

Eligibility Criteria

Criteria

Ages Eligible for Study:
65 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • isolated displaced femoral neck fracture (AO type 31-B2 and 31 B3)

  • age≥65 years

  • preinjury ambulation with or without a gait aid

  • surgical intervention ≤ 48 hours after fracture.

Exclusion Criteria:
  • age <65 years

  • patients with other fractures or dislocations

  • wheelchair bound

  • 48 hours between fracture and surgery, presence or history of infection, active metastatic disease, previous ipsilateral hip prosthesis

  • active major psychiatric illness

  • active drug or alcohol abuse

  • BMI >40, and actively failing contralateral hip prosthesis.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Mayo Clinic Rochester Minnesota United States 55905

Sponsors and Collaborators

  • Mayo Clinic

Investigators

  • Principal Investigator: Cross W. William, M.D., Mayo Clinic

Study Documents (Full-Text)

None provided.

More Information

Additional Information:

Publications

None provided.
Responsible Party:
William W. Cross, III M.D., Assistant Professor of Orthopedics,, Mayo Clinic
ClinicalTrials.gov Identifier:
NCT02959320
Other Study ID Numbers:
  • 16-003695
First Posted:
Nov 9, 2016
Last Update Posted:
Mar 25, 2022
Last Verified:
Mar 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Additional relevant MeSH terms: