EVOLVE-HF: Evaluation of Outcomes of CRT and MitraClip for Treatment of Low Ejection Fraction and Functional Mitral Regurgitation in HF

Sponsor
Montreal Heart Institute (Other)
Overall Status
Withdrawn
CT.gov ID
NCT02985268
Collaborator
(none)
0
4
38

Study Details

Study Description

Brief Summary

At present, the optimal treatment strategy for heart failure patients and moderate-to-severe (3+) or severe (4+) mitral regurgitation with a class IIa recommendation for CRT is uncertain.Whether these patents should also be treated for functional mitral regurgitation or with CRT also remains unclear. We therefore propose a randomized 2x2 factorial design in this patient population to understand the the impact of both CRT and transcatheter mitral valve repair with the MitraClip on their functional status and quality of life.

Condition or Disease Intervention/Treatment Phase
  • Device: MitraClip
  • Drug: Optimal Medical Therapy
  • Device: CRT-D
N/A

Study Design

Study Type:
Interventional
Actual Enrollment :
0 participants
Allocation:
Randomized
Intervention Model:
Factorial Assignment
Masking:
Triple (Participant, Care Provider, Outcomes Assessor)
Primary Purpose:
Treatment
Official Title:
Evaluation of Outcomes of Cardiac Resynchronization Therapy and MitraClip for the Treatment of Low Ejection Fraction and Functional Mitral Valve Regurgitation in Heart Failure
Study Start Date :
Dec 1, 2016
Anticipated Primary Completion Date :
Dec 1, 2019
Anticipated Study Completion Date :
Feb 1, 2020

Arms and Interventions

Arm Intervention/Treatment
Active Comparator: MitraClip/Optimal Medical Therapy (OMT) and CRT ON

Patient to be implanted with both MitraClip and CRT-D. Will also receive optimal medical therapy. CRT-D will be programmed to ON

Device: MitraClip
The MitraClip Clip Delivery System is indicated for the percutaneous reduction of significant symptomatic mitral regurgitation (MR ≥ 3+) due to primary abnormality of the mitral apparatus [degenerative MR] in patients who have been determined to be at prohibitive risk for mitral valve surgery by a heart team, which includes a cardiac surgeon experienced in mitral valve surgery and a cardiologist experienced in mitral valve disease, and in whom existing comorbidities would not preclude the expected benefit from reduction of the mitral regurgitation.

Drug: Optimal Medical Therapy
Optimal medical therapy administered as per the Guideline Direct Medical Therapy (GDMT) as defined in the 2013 ACCF/AHA Heart Failure Guidelines with maximum tolerated doses of an ACE-inhibitor or Angiotensin Receptor Blocker (ARB) and beta-blocker
Other Names:
  • OMT
  • Device: CRT-D
    Cardiac Resynchronization Therapy with defibrillation therapy devices will be implanted according to the Heart Rhythm Society Guidelines for implanted devices.
    Other Names:
  • Cardiac Resynchronization Therapy and Defibrillator
  • Active Comparator: MitraClip/OMT and CRT OFF

    Patient to be implanted with both MitraClip and CRT-D. Will also receive optimal medical therapy. CRT-D will be programmed to OFF until the 6-month follow-up visit in which the CRT will be turned ON

    Device: MitraClip
    The MitraClip Clip Delivery System is indicated for the percutaneous reduction of significant symptomatic mitral regurgitation (MR ≥ 3+) due to primary abnormality of the mitral apparatus [degenerative MR] in patients who have been determined to be at prohibitive risk for mitral valve surgery by a heart team, which includes a cardiac surgeon experienced in mitral valve surgery and a cardiologist experienced in mitral valve disease, and in whom existing comorbidities would not preclude the expected benefit from reduction of the mitral regurgitation.

    Drug: Optimal Medical Therapy
    Optimal medical therapy administered as per the Guideline Direct Medical Therapy (GDMT) as defined in the 2013 ACCF/AHA Heart Failure Guidelines with maximum tolerated doses of an ACE-inhibitor or Angiotensin Receptor Blocker (ARB) and beta-blocker
    Other Names:
  • OMT
  • Device: CRT-D
    Cardiac Resynchronization Therapy with defibrillation therapy devices will be implanted according to the Heart Rhythm Society Guidelines for implanted devices.
    Other Names:
  • Cardiac Resynchronization Therapy and Defibrillator
  • Active Comparator: OMT and CRT ON

    Patient to be implanted with only the CRT-D and will receive optimal medical therapy. CRT-D will be programmed to ON

    Drug: Optimal Medical Therapy
    Optimal medical therapy administered as per the Guideline Direct Medical Therapy (GDMT) as defined in the 2013 ACCF/AHA Heart Failure Guidelines with maximum tolerated doses of an ACE-inhibitor or Angiotensin Receptor Blocker (ARB) and beta-blocker
    Other Names:
  • OMT
  • Device: CRT-D
    Cardiac Resynchronization Therapy with defibrillation therapy devices will be implanted according to the Heart Rhythm Society Guidelines for implanted devices.
    Other Names:
  • Cardiac Resynchronization Therapy and Defibrillator
  • Active Comparator: OMT and CRT OFF

    Patient to be implanted with only the CRT-D and will receive optimal medical therapy. CRT-D will be programmed to OFF until the 6-month follow-up visit in which the CRT will be turned ON

    Drug: Optimal Medical Therapy
    Optimal medical therapy administered as per the Guideline Direct Medical Therapy (GDMT) as defined in the 2013 ACCF/AHA Heart Failure Guidelines with maximum tolerated doses of an ACE-inhibitor or Angiotensin Receptor Blocker (ARB) and beta-blocker
    Other Names:
  • OMT
  • Device: CRT-D
    Cardiac Resynchronization Therapy with defibrillation therapy devices will be implanted according to the Heart Rhythm Society Guidelines for implanted devices.
    Other Names:
  • Cardiac Resynchronization Therapy and Defibrillator
  • Outcome Measures

    Primary Outcome Measures

    1. Improvement in distance walked on a six-minute walk test (6MWT) [Baseline to 6 months]

    Secondary Outcome Measures

    1. Change in cardiographic endpoints [Baseline to 6 months]

      Mitral regurgitation severity

    2. Change in cardiographic endpoints [Baseline to 6 months]

      Indexed left ventricular end-systolic volume (LVESVi)

    3. Change in cardiographic endpoints [Baseline to 6 months]

      Left ventricular ejection fraction (LVEF)

    4. Change in Quality of Life Assessment scores [Baseline to 6 months]

      Kansas City Cardiomyopathy Questionnaire (KCCQ)

    5. Change in Quality of Life Assessment scores [Baseline to 6 months]

      Euro Quality of Life Questionnaire (EQ5DL)

    6. Number of Re-hospitalizations for decompensated heart failure [6 and 12 months]

    Other Outcome Measures

    1. Wearable activity/heart rate sensor (Fitbit Charge 2) [12 months]

      Assessments obtained from the wearable activity/heart rate sensor: Mean daily heart rate Daily heart rate range calculated as the difference between min and max heart rate number of daily steps number of daily hours of sleep

    2. Major Adverse Cardiac Event (MACE) [12 months]

      Time to major adverse cardiac events: Cardiovascular death All -cause mortality non-fatal Myocardial Infarction fatal and non-fatal stroke rehospitalization for decompensated heart failure

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    N/A and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    1. Symptomatic moderate-to-severe (3+) or severe (4+) functional mitral regurgitation due to cardiomyopathy of either ischemic or non-ischemic etiology as determined by transthoracic echocardiogram (TTE), and confirmed by the Echocardiography Core Lab (ECL);

    2. Symptomatic heart failure as defined by New York Heart Association (NYHA) class II, III or ambulatory IV;

    3. Treatment and compliance with optimal medical therapy for heart failure for at least 30 days; Optimal medical therapy is defined by: Maximum tolerated beta-blocker, angiotensin converting enzyme inhibitor (ACE) or angiotensin receptor blocker (ARB), and aldosterone antagonist (as per the ACCF/AHA Guidelines as judged by the HF specialist investigator on site and confirmed by the Clinical Eligibility Committee).

    4. Left ventricular ejection fraction ≤ 35%, as assessed by any one of the following methods: echocardiography, contrast left ventriculography, gated blood pool scan or cardiac magnetic resonance imaging (MRI);

    5. Class IIa indication for cardiac resynchronization therapy:

    6. Left bundle branch block (LBBB) and QRS duration of 120-149 ms;

    7. Right bundle branch block (RBBB) and QRS ≥ 150 ms.

    8. Clinical agreement amongst local investigators that the patient will not be offered surgical intervention;

    9. The primary regurgitant jet, in the opinion of the MitraClip implanting investigator, can successfully be treated by the MitraClip. Treatment of commissural mitral regurgitation may be treated at the discretion of the operator. All major jets contributing the secondary MR will be treated with the MitraClip;

    10. Ability to perform a six-minute walk test (6MWT) without substantial physical limitations and without use of a walker or wheelchair and distance walked in 6 minutes of ≤ 450m;

    11. Ability and willingness to give written informed consent and to comply with the requirements of the study.

    Exclusion Criteria:
    1. Life expectancy less than 12 months due to noncardiac conditions;

    2. ACC/AHA Stage D Heart Failure;

    3. Left ventricular ejection fraction ≤ 15%;

    4. Hypotension (systolic pressure <90 mm Hg) or requirement for inotropic support or mechanical hemodynamic support;

    5. United Network for Organ Sharing (UNOS) status 1 heart transplantation or prior orthotopic heart transplantation;

    6. Untreated clinically significant coronary artery disease requiring revascularization;

    7. CABG within prior 30 days;

    8. Percutaneous coronary intervention within prior 30 days;

    9. Severe Chronic Obstructive Pulmonary Disease (COPD) requiring continuous daytime home oxygen or chronic oral corticosteroid therapy;

    10. Previous surgical mitral valve bioprosthesis, mitral annuloplasty, or transcatheter mitral valve procedure;

    11. Positive pregnancy test, or woman of child bearing potential not using highly effective methods of contraception;

    12. Mitral valve area <4.0 cm2 as assessed by planimetry of the mitral valve;

    13. Subjects in whom trans-esophageal echocardiography is contraindicated or high risk;

    14. Mitral leaflet anatomy which may preclude MitraClip implantation:

    15. Perforated mitral leaflets or clefts, lack of primary or secondary chordal support;

    16. Severe calcification in the grasping area;

    17. Rheumatic valve disease.

    18. Previously implanted Cardiac Resynchronization Therapy and Defibrillator (CRT-D) system;

    19. Stroke or transient ischemic event within 30 days before randomization;

    20. Modified Rankin Scale >4 disability;

    21. Need for emergent or urgent surgery for any reason or any planned cardiac surgery within the next 12 months;

    22. Severe renal impairment defined as an Estimated Glomerular Filtration Rate (eGFR) <30 mL/min/1.73m2 as calculated by the Modification in Diet in Renal Disease (MDRD) formula;

    23. Severe anemia requiring transfusional support or therapy with erythropoietin;

    24. Physical evidence of right-sided congestive heart failure with echocardiographic evidence of moderate or severe right ventricular dysfunction;

    25. Aortic valve disease requiring surgery or transcatheter intervention;

    26. Significant tricuspid valve disease requiring surgical intervention or very severe tricuspid regurgitation;

    27. Active infection requiring antibiotic therapy;

    28. Active endocarditis or active rheumatic heart disease or leaflets degenerated from rheumatic disease;

    29. Echocardiographic evidence of intracardiac mass, thrombus or vegetation;

    30. Any condition making it unlikely the patient will be able to complete all protocol procedures (including compliance with guideline directed medical therapy) and follow-up visits;

    31. Presence of any of the following:

    32. Pulmonary artery systolic pressure (PASP) > 70 mm Hg confirmed by right heart catheterization;

    33. Infiltrative cardiomyopathies.

    34. Any other condition(s) that would compromise the safety of the patient as judged by the site principal investigator.

    Contacts and Locations

    Locations

    No locations specified.

    Sponsors and Collaborators

    • Montreal Heart Institute

    Investigators

    • Principal Investigator: Anita Asgar, MD, Montreal Heart Institute

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Montreal Heart Institute
    ClinicalTrials.gov Identifier:
    NCT02985268
    Other Study ID Numbers:
    • MHICC-2016-001
    First Posted:
    Dec 7, 2016
    Last Update Posted:
    Feb 27, 2020
    Last Verified:
    Feb 1, 2020
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Keywords provided by Montreal Heart Institute
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Feb 27, 2020