Handheld 3D Lumbar Spine Navigation: A Clinical Validation Study RM002

Sponsor
University of Virginia (Other)
Overall Status
Completed
CT.gov ID
NCT02442973
Collaborator
Rivanna Medical, LLC (Other)
130
1
23.4
5.6

Study Details

Study Description

Brief Summary

Currently, at UVA, handheld ultrasound devices (like those used to view an unborn baby) are only two dimensional. The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures. Epidural analgesia is the mainstay procedure for the management of labor pain. The precise placement of a needle or catheter in proximity to landmarks of the spinal bone anatomy is required for the procedure to succeed. The current standard of care is called the 'blind approach' (i.e. without medical imaging) and involves a physician manually palpating a patient's back to locate spinal bone landmarks. The needle is then inserted with respect to the location of the landmarks and inserted until a loss-of-resistance is manually detected. This approach, while most common, has been associated with success rates as low as 68% in obese patients (2).

Alternative methods have been investigated for this problem, including ultrasound (US) guidance, which offers real-time imaging. Several studies have demonstrated ultrasound's efficacy for spinal anesthesia (1-6). However, standard US systems are engineered to image soft tissue rather than bone structures, with the consequence that bone is imaged poorly. US images are often degraded by a number of noise sources including speckle noise, reverberations and off-axis scattering, particularly when bone is present, making visualization of bone anatomy features difficult. Moreover, arranging access to ultrasound for the purpose of spinal anesthesia alone is cumbersome. Thus, the efficacy of guided spinal anesthesia and diagnostic procedures using standard ultrasound systems is limited and the benefits that it offers are heavily dependent on the user's familiarity and skill with ultrasonography (4).

Recently, new medical imaging technologies have been developed at Rivanna Medical, LLC to address the significant clinical need for technological advances that improve the placement of spinal anesthesia, epidural analgesia and other diagnostic procedures. The Accuro is a pocket-sized and battery operated ultrasound instrument that incorporates new signal processing-based technologies for enhanced bone imaging including 3D navigation of the lumbar spine. The device is a single self-contained unit consisting of an ultrasound system, ultrasound probe, and rotatable touchscreen display. The instrument enables a SpineView3D™ technology to facilitate spinal anesthesia guidance with real-time 3D navigation of the lumbar spine anatomy.

SpineView3D™ technology facilitates image interpretation of individual 2D lumbar spine scans by automating spinal bone landmark detection and depth measurements and providing a real-time assessment of scan plane orientation in 3D. SpineView3D™ makes image interpretation and measurements of the lumbar spine anatomy simple, quick, and easy. Real-time 2D scans from either SpineView3D™ or general-purpose bone presets are formed using patent-pending BoneEnhance+™ technology. The BoneEnhance+™ technology provides images of bone anatomy at greater bone-to-tissue contrast compared with conventional ultrasound image reconstructions.

Condition or Disease Intervention/Treatment Phase
  • Procedure: Control group (CG): standard practice
  • Procedure: Ultrasound group (UG):
  • Device: Accuro SpineView3D™

Study Design

Study Type:
Observational
Actual Enrollment :
130 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Handheld 3D Lumbar Spine Navigation: A Clinical Validation Study RM002
Study Start Date :
Feb 1, 2016
Actual Primary Completion Date :
Jan 12, 2018
Actual Study Completion Date :
Jan 12, 2018

Arms and Interventions

Arm Intervention/Treatment
Control group (CG):

Standard practice group

Procedure: Control group (CG): standard practice
Standard practice group
Other Names:
  • CG
  • Ultrasound group (UG):

    SpineView3D™ anatomical "scouting" approach

    Procedure: Ultrasound group (UG):
    SpineView3D™ anatomical "scouting" approach
    Other Names:
  • UG
  • Device: Accuro SpineView3D™
    subject will be scanned with 'Accuro SpineView3D
    Other Names:
  • scan
  • Outcome Measures

    Primary Outcome Measures

    1. Success rates: [1 day]

      defined as successful epidural administration on the first needle insertion attempt.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 40 Years
    Sexes Eligible for Study:
    Female
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:

    Patients between the ages of 18 and 40 presenting for delivery and planning epidural anesthesia

    • ASA-1 and ASA-2

    • BMI > 30

    Exclusion Criteria:

    Patients with known spinal deformities allergies to ultrasound gel

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 University of Virginia Health System Charlottesville Virginia United States 22908

    Sponsors and Collaborators

    • University of Virginia
    • Rivanna Medical, LLC

    Investigators

    • Principal Investigator: Mohammed Tiouririne, MD, UVA Health System

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    Responsible Party:
    Mohamed Tiouririne, MD, UVA Anesthesiology Faculty, University of Virginia
    ClinicalTrials.gov Identifier:
    NCT02442973
    Other Study ID Numbers:
    • Rivanna Clin-002
    First Posted:
    May 13, 2015
    Last Update Posted:
    Mar 10, 2022
    Last Verified:
    Mar 1, 2022
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No