Single-Sided Deafness in the Medicare Population

Sponsor
Med-El Corporation (Industry)
Overall Status
Recruiting
CT.gov ID
NCT05250414
Collaborator
(none)
15
3
1
21.2
5
0.2

Study Details

Study Description

Brief Summary

The purpose of this study is to evaluate the safety and effectiveness of cochlear implantation in adults 65 years of age and older.

Condition or Disease Intervention/Treatment Phase
  • Device: MED-EL Cochlear Implant System
N/A

Detailed Description

The study will be conducted as a single-subject, repeated measures, multi center study at 3 sites. Fifteen subjects will be enrolled in this study. Three centers in the United States and Canada will recruit subjects into this study. Study subjects will be followed for 12 months post-implantation of the device.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
15 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
Cochlear Implantation in the Single-Sided Deafness in the Medicare Population
Actual Study Start Date :
Jun 27, 2022
Anticipated Primary Completion Date :
Apr 1, 2023
Anticipated Study Completion Date :
Apr 1, 2024

Arms and Interventions

Arm Intervention/Treatment
Other: Study Procedure

Device: MED-EL Cochlear Implant System
Cochlear implant and audio processor

Outcome Measures

Primary Outcome Measures

  1. Performance of the Cochlear Implant System will be assessed through speech perception testing in noise completed through one year (12 months) post implantation. [One year (12 months) post implantation]

    The primary effectiveness endpoint will be change on speech in noise when speech is presented to the front and noise is presented to the acoustic hearing (contralateral) ear. The pre-operative, best aided score will be compared to the 6-month and 12-month CI score for AzBio sentences in noise (range of score 0-100, higher score is better). Improvement is defined as greater than or equal to 10 percentage points.

Secondary Outcome Measures

  1. Performance of the Cochlear Implant System will be summarized through speech perception testing in noise completed through one year (12 months) post implantation. [One year (12 months) post implantation]

    Speech in noise in two spatial conditions will demonstrate similar performance from the pre-operative, best-aided score to the CI score at 6- and 12-months post activation. AzBio sentence in noise score will be summarized for two conditions: speech and noise presented from the front as well as speech presented to the front and noise presented to the CI ear. (Range of score 0-100, higher score is better)

  2. Performance of the Cochlear Implant System will be assessed through speech perception testing in quiet completed through one year (12 months ) post implantation. [One year (12 months) post implantation]

    Speech perception in quiet will be summarized for the CI ear as well as the contralateral ear at the pre-operative, 6-month, and 12-month intervals. The CI ear is expected to demonstrate improvement (greater than or equal to 10 percentage point change), while the contralateral ear is expected to demonstrate no change. (Range of score 0-100, higher score is better)

  3. Subjective benefit of the Cochlear Implant System will be assessed through one year (12 months) post implantation. [One year (12 months) post implantation]

    Subjective data will be collected via the Speech, Spatial, and Qualities of Hearing Scale (SSQ). Responses will be summarized from the pre-operative, 6-month, and 12-month intervals. (Range of score 0-10, lower score is better)

  4. Safety will be evaluated for all study subjects through one year (12 months) post implantation. [One year (12 months) post implantation]

    Safety will be assessed by collecting and reporting device-related adverse events occurring throughout the study. This will be summarized and reported as the number and proportion of subjects experiencing an adverse device event.

Eligibility Criteria

Criteria

Ages Eligible for Study:
65 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • 65 years of age or older at the time of implantation

  • Unilateral profound hearing loss, as defined by a pure-tone average (500, 1000, 2000, and 4000 Hz) of 90 dB or greater in the ear to be implanted

  • Sensorineural hearing loss in the ear to be implanted, as defined by an air-bone gap less than or equal to 10 dB at two or more frequencies out of 500, 1000, 2000, and 4000 Hz

  • Normal or near-normal hearing in the non-implanted ear, as defined by a pure-tone average (500, 1000, 2000, and 4000 Hz) of 30 dB or less

  • Word recognition in the ear to be implanted of 5% or less on CNC word score in quiet

  • Previous experience with an appropriately-fit CROS, BI-CROS, bone conduction, or traditional hearing aid, as deemed appropriate by investigator

  • Fluent in English

Exclusion Criteria:
  • Duration of profound hearing loss of 10 years or more

  • Sudden onset of hearing loss within six months of implantation

  • Evidence of non-functional cochlear nerve or other retrocochlear hearing loss

  • Evidence of severe cochlear malformation (i.e., common cavity or ossification)

  • External or middle ear infection

  • Suspected cognitive concern

  • Other medical contraindication for surgery or anesthesia

Contacts and Locations

Locations

Site City State Country Postal Code
1 University of Iowa Hospitals and Clinics Iowa City Iowa United States 52242
2 University of North Carolina Chapel Hill North Carolina United States 27599
3 Sunnybrook Health Sciences Centre Toronto Ontario Canada M4N 3M5

Sponsors and Collaborators

  • Med-El Corporation

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

Responsible Party:
Med-El Corporation
ClinicalTrials.gov Identifier:
NCT05250414
Other Study ID Numbers:
  • MED-EL SSD CMS
First Posted:
Feb 22, 2022
Last Update Posted:
Jul 1, 2022
Last Verified:
Jun 1, 2022
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jul 1, 2022