Efficacy of Continuous Glucose Monitoring in Neonates With Hypoglycemia

Sponsor
Boston Children's Hospital (Other)
Overall Status
Terminated
CT.gov ID
NCT02300285
Collaborator
(none)
6
1
2
42.9
0.1

Study Details

Study Description

Brief Summary

Our aim is to determine the feasibility of using continuous glucose monitors (CGMs) in infants with low blood glucose to improve how we care for these infants. To do this we plan on monitoring blood glucose levels with CGMs (instead of only with intermittent bloodsampling) in late-preterm and term infants admitted to the NICU who have had hypoglycemia. To see if using CGMs helps us prevent low blood glucose levels and allows us to find a diagnosis and treat sooner, we will randomize patients into one of two groups: a "CGM group" where the CGM information is made available to the NICU team and a "Standard of Care" group where the CGM information will only be available to the research team. However, if infants in the "Standard of Care" group are noted to have three unrecognized severe low blood glucose levels then the research team will inform the NICU team that this has occurred.

Condition or Disease Intervention/Treatment Phase
  • Device: Continuous Glucose Monitoring
N/A

Detailed Description

We aim to evaluate the utility of continuous glucose monitors (CGMs) in improving the diagnosis and management of neonatal hypoglycemia in infants admitted to the neonatal intensive care unit (NICU). Specifically, we hope to assess whether the use of CGMs in this population reduces the number and severity of hypoglycemic events, reduces the time to diagnosis of the etiology of hypoglycemia and/or reduces the time taken to achieve stable euglycemia on a sustainable feeding regimen. We plan to perform a prospective pilot and feasibility study comparing the clinical course and outcomes of newborns with hypoglycemia admitted to the NICU who are actively monitored with CGMs versus those who receive routine care. Eligible infants will be late preterm and term infants admitted to the Boston Children's Hospital who have had two documented hypoglycemic episodes during their current admission. Families will be approached for consent shortly after diagnosis of recurrent hypoglycemia. As all of these infants will be undergoing periodic blood glucose monitoring as part of their routine care, enrollment in this study will involve minimal additional interventions, including CGM placement, which involves placement of a small subcutaneous needle sensor, and the possibility of drawing additional blood glucose samples if hypoglycemia is detected by CGM. All enrolled infants will be placed on a CGM monitor and then randomized to either the "CGM Protocol" or "Standard of Care" group. Those on the CGM Protocol will have a fully accessible CGM that will be analyzed for blood glucose trends and will alarm for any blood glucose level approaching hypoglycemic threshold (eg. BG <70 mg/dL). Those in the "Standard of Care" group will have a CGM in place, but values will not be available to the clinical team except if severe hypoglycemia is recorded (eg. BG <40 mg/dL). Whenever the CGM alarms or there is a concerning blood glucose trend as measured by the CGM, the nurse will be asked to check a blood glucose value. All clinical management decisions will be made by the clinical team based on confirmed blood glucose values. In the control group, the only change to current management is the potential performance of additional blood glucose checks that may be prompted by CGM alarms for severe hypoglycemia. The CGM will remain in place until the infant is no longer being monitored for glycemic stability or the infant is discharged. We will record all blood glucose levels, laboratory data related to investigation of the underlying cause of hypoglycemia, all intravenous and enteral sources of glucose, and uses of other therapeutic interventions such as diazoxide and carnitine replacement. We will also compare blood glucose data with information from the CGM monitors to assess accuracy. We will then compare severity and frequency of hypoglycemia, as well as times to diagnosis and euglycemia between the "CGM" and "Standard of Care" groups.

Study Design

Study Type:
Interventional
Actual Enrollment :
6 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Efficacy of Continuous Glucose Monitoring in Neonates With Hypoglycemia
Study Start Date :
Feb 1, 2015
Actual Primary Completion Date :
Aug 30, 2018
Actual Study Completion Date :
Aug 30, 2018

Arms and Interventions

Arm Intervention/Treatment
Experimental: CGM Protocol

Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements.

Device: Continuous Glucose Monitoring
Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
Other Names:
  • Dexcom G4 Platinum
  • Placebo Comparator: Standard of Care

    Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements.

    Device: Continuous Glucose Monitoring
    Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Other Names:
  • Dexcom G4 Platinum
  • Outcome Measures

    Primary Outcome Measures

    1. Frequency of Hypoglycemic Events [Up to 28 days]

      Hypoglycemia is defined by age group: for patients less than 48 hours of life, hypoglycemia is defined as glucose level < 50 mg/dL for patients greater than or equal to 48 hours of life it is defined as glucose level < 70 mg/dL.

    2. Frequency of Severe Hypoglycemia Events [Up to 28 days]

      Severe hypoglycemia is defined as glucose level < 40 mg/dL

    Secondary Outcome Measures

    1. Number of Events Where Etiology of Hypoglycemia Was Established [up tp 28 days]

      Diagnosis of the etiology of hypoglycemia, and the time to to do, will be evaluated in order to determine if the use of CGM will prompt earlier testing to evaluate the etiology of the hypoglycemia and therefore lead to earlier ascertainment of the underlying etiology. Diagnosis of etiology.

    2. Time to Diagnosis of Etiology of Hypoglycemia [Up to 28 days]

      Diagnosis of the etiology of hypoglycemia, and the time to to do, will be evaluated in order to determine if the use of CGM will prompt earlier testing to evaluate the etiology of the hypoglycemia and therefore lead to earlier ascertainment of the underlying etiology. Time to diagnosis of etiology.

    3. Time to Stable Euglycemia [Up to 28 days]

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    N/A to 60 Days
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion criteria:
    • Age 0-60 days old

    • Late-preterm and term infants (babies born more than 33 weeks and 6 days after the start of the pregnancy)

    • History of low blood sugars (hypoglycemia): two episodes of hypoglycemia more than 1 hour apart (low blood sugar will be defined by age: for those less than 48 hours old a low blood sugar is considered less than 50mg/dL and for those older than 48 hours old less than 70mg/dL)

    Exclusion Criteria:
    • Infants with skin disease such that placement of a glucose sensor under the skin would be difficult to secure

    • Infants expected to remain in NICU less than 24 hours

    • Infants on a hypothermic protocol

    • Infants enrolled in a competing clinical trial

    • Family/team have decided to limit or redirect from aggressive NICU technological support

    • infants who are wards of the state

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 Boston Children's Hospital Boston Massachusetts United States 02115

    Sponsors and Collaborators

    • Boston Children's Hospital

    Investigators

    • Principal Investigator: Michael Agus, MD, Boston Children's Hospital

    Study Documents (Full-Text)

    More Information

    Publications

    Responsible Party:
    Michael Agus, Principal Investigator, Boston Children's Hospital
    ClinicalTrials.gov Identifier:
    NCT02300285
    Other Study ID Numbers:
    • IRB-P00014699
    First Posted:
    Nov 25, 2014
    Last Update Posted:
    Nov 1, 2021
    Last Verified:
    Oct 1, 2021
    Additional relevant MeSH terms:

    Study Results

    Participant Flow

    Recruitment Details
    Pre-assignment Detail
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Period Title: Overall Study
    STARTED 3 3
    COMPLETED 3 3
    NOT COMPLETED 0 0

    Baseline Characteristics

    Arm/Group Title CGM Protocol Standard of Care Total
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia. Total of all reporting groups
    Overall Participants 3 3 6
    Age (Days) [Mean (Full Range) ]
    Mean (Full Range) [Days]
    3.0
    3.33
    3.17
    Sex: Female, Male (Count of Participants)
    Female
    2
    66.7%
    2
    66.7%
    4
    66.7%
    Male
    1
    33.3%
    1
    33.3%
    2
    33.3%
    Race and Ethnicity Not Collected (Count of Participants)
    Count of Participants [Participants]
    0
    0%
    Region of Enrollment (participants) [Number]
    United States
    3
    100%
    3
    100%
    6
    100%

    Outcome Measures

    1. Primary Outcome
    Title Frequency of Hypoglycemic Events
    Description Hypoglycemia is defined by age group: for patients less than 48 hours of life, hypoglycemia is defined as glucose level < 50 mg/dL for patients greater than or equal to 48 hours of life it is defined as glucose level < 70 mg/dL.
    Time Frame Up to 28 days

    Outcome Measure Data

    Analysis Population Description
    [Not Specified]
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Measure Participants 3 3
    Mean (Standard Deviation) [Events]
    14
    (2)
    19
    (3)
    2. Primary Outcome
    Title Frequency of Severe Hypoglycemia Events
    Description Severe hypoglycemia is defined as glucose level < 40 mg/dL
    Time Frame Up to 28 days

    Outcome Measure Data

    Analysis Population Description
    [Not Specified]
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Measure Participants 3 3
    Number [Events]
    1
    4
    3. Secondary Outcome
    Title Number of Events Where Etiology of Hypoglycemia Was Established
    Description Diagnosis of the etiology of hypoglycemia, and the time to to do, will be evaluated in order to determine if the use of CGM will prompt earlier testing to evaluate the etiology of the hypoglycemia and therefore lead to earlier ascertainment of the underlying etiology. Diagnosis of etiology.
    Time Frame up tp 28 days

    Outcome Measure Data

    Analysis Population Description
    Events of diagnosis of hyperinsulinemic hypoglycemia
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Measure Participants 3 3
    Number [Events]
    2
    1
    4. Secondary Outcome
    Title Time to Diagnosis of Etiology of Hypoglycemia
    Description Diagnosis of the etiology of hypoglycemia, and the time to to do, will be evaluated in order to determine if the use of CGM will prompt earlier testing to evaluate the etiology of the hypoglycemia and therefore lead to earlier ascertainment of the underlying etiology. Time to diagnosis of etiology.
    Time Frame Up to 28 days

    Outcome Measure Data

    Analysis Population Description
    [Not Specified]
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Measure Participants 3 3
    Mean (Full Range) [Days]
    1.5
    4
    5. Secondary Outcome
    Title Time to Stable Euglycemia
    Description
    Time Frame Up to 28 days

    Outcome Measure Data

    Analysis Population Description
    Patients did not remain on protocol until euglycemia was reached, therefore no data was collected for this Outcome Measure.
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    Measure Participants 0 0

    Adverse Events

    Time Frame Up to 28 days from enrollment and insertion of initial continuous glucose glucose monitor sensor.
    Adverse Event Reporting Description This is a Non-Significant-Risk (NSR) device study. If it is determined that an unanticipated adverse device effect presents an unreasonable risk to subjects, all investigations or parts of the investigations presenting that risk will be terminated as soon as possible and no later than 5 working days after the sponsor makes this determination. Because this is a small pilot study with minimal risk, no specific stopping rules will be developed and no interim analysis will be performed.
    Arm/Group Title CGM Protocol Standard of Care
    Arm/Group Description Subjects will receive continuous glucose monitoring and caregivers will be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the CGM protocol group the CGM will let the medical team know if there is a concerning blood sugar level, so that the medical team can then check a blood sugar level by the standard way (usually in a small drop of blood) and then decide if they need to give any medical treatment. Subjects will receive continuous glucose monitoring but caregivers will not be able to view continuous glucose measurements. Continuous Glucose Monitoring: Continuous glucose monitors (CGM) will be used to monitor blood sugar levels in enrolled subjects. CGMs measure blood sugar in the tissue just under the skin every few seconds and report average blood sugar every 5 minutes. In our study, the CGMs will function as monitoring systems. In the Standard of Care group the CGM data will not be visible to the medical team but the medical team will be informed by the researchers if there are multiple unrecognized episodes of severe hypoglycemia.
    All Cause Mortality
    CGM Protocol Standard of Care
    Affected / at Risk (%) # Events Affected / at Risk (%) # Events
    Total 0/3 (0%) 0/3 (0%)
    Serious Adverse Events
    CGM Protocol Standard of Care
    Affected / at Risk (%) # Events Affected / at Risk (%) # Events
    Total 0/3 (0%) 0/3 (0%)
    Other (Not Including Serious) Adverse Events
    CGM Protocol Standard of Care
    Affected / at Risk (%) # Events Affected / at Risk (%) # Events
    Total 0/3 (0%) 0/3 (0%)

    Limitations/Caveats

    The trial terminated due to lack of enrollment, thus limited data are available.

    More Information

    Certain Agreements

    All Principal Investigators ARE employed by the organization sponsoring the study.

    There is NOT an agreement between Principal Investigators and the Sponsor (or its agents) that restricts the PI's rights to discuss or publish trial results after the trial is completed.

    Results Point of Contact

    Name/Title Michael SD Agus, MD
    Organization Boston Children's Hospital
    Phone 617 355-5849
    Email michael.agus@childrens.harvard..edu
    Responsible Party:
    Michael Agus, Principal Investigator, Boston Children's Hospital
    ClinicalTrials.gov Identifier:
    NCT02300285
    Other Study ID Numbers:
    • IRB-P00014699
    First Posted:
    Nov 25, 2014
    Last Update Posted:
    Nov 1, 2021
    Last Verified:
    Oct 1, 2021