Implantation of Add on Lens for Age Related Macular Degeneration Patients With Low Vision

Sponsor
Rabin Medical Center (Other)
Overall Status
Unknown status
CT.gov ID
NCT03061682
Collaborator
(none)
20
1
22

Study Details

Study Description

Brief Summary

Age related macular degeneration (AMD) is the leading cause of vision loss in patients older than 55 years old. AMD can present as dry AMD or wet AMD. In most cases AMD affects both eyes although in many cases it's asymmetrical as far as severity. Some patients require low vision aids to continue their daily life tasks. In the past a few attempts were made to use low vision intraocular lenses with corrective glasses without enough success. In addition telescopic and prismatic lenses were also tried. The difficulties with these lenses included low field of vision, unsatisfactory magnification, complicated surgical technique and high complication rates.

Recently an add on lens was designed for the sulcus for implantation in pseudophakic AMD patients. The add on lens doubles the magnification of the central image dependent on the reading distance and the anatomy of the eye.

The lens is acrylic hydrophobic and designed for implantation in the sulcus either in pseudophakic patients or in addition to an intraocular lens implanted during a routine cataract surgery. The lens is 13 mm wide with 4 symmetric haptics. The lens has 1.5 mm central part of 10 diopters and the rest of the lens has no optical power.

Our purpose is to study implantation of the lenses in AMD patients to improve their reading ability and to improve their daily living.

Condition or Disease Intervention/Treatment Phase
  • Device: "Scharioth" macula lens A45sml/A45smy
N/A

Detailed Description

Study design Prospective study on implantation of the add on lenses in AMD patients. The study was approved by Rabin medical center IRB.

Patients will be examined for best corrected visual acuity prior to the surgery at 6 meter and for reading at 40 and 15 cm. Improvement of the reading ability at 15 cm compared to 40 cm will predict the potential for vision improvement with the add on lens.

Before the surgery patients will have a full ophthalmological examination. Patients will have axial length and keratometry examination using the biometry. The lens will be implanted in surgery through a 2.2 mm clear cornea and will be injected and positioned in the sulcus.

Patients will be followed up at 1 day, 1 week, 4 weeks, 4 and 6 months following surgery. During follow up patients will undergo full ophthalmic exam and well as visual acuity both for distance and near.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
20 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Other
Official Title:
Implantation of Add on Lens for Age Related Macular Degeneration Patients With Low Vision
Anticipated Study Start Date :
Mar 1, 2017
Anticipated Primary Completion Date :
Jan 1, 2019
Anticipated Study Completion Date :
Jan 1, 2019

Arms and Interventions

Arm Intervention/Treatment
Experimental: Add on lens

Device: "Scharioth" macula lens A45sml/A45smy
Implantation of an add on intraocular lens to low vision patients

Outcome Measures

Primary Outcome Measures

  1. near visual acuity [last study visit - 6 months post surgery]

Eligibility Criteria

Criteria

Ages Eligible for Study:
50 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Pseudophakic patients with non-active AMD that complain on near distance reading with a distance visual acuity better than 6/60.
Exclusion Criteria:
  • Exudative AMD with fluids, advanced glaucoma, advance visual field defects, aphakia, following complicated cataract surgery with PCIOL in the sulcus , phacodonesis, chronic uveitis, rubeosis iridis, central corneal opacity.

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • Rabin Medical Center

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
rita ehrlich, Principal Investigator, Rabin Medical Center
ClinicalTrials.gov Identifier:
NCT03061682
Other Study ID Numbers:
  • 0408-15RMC
First Posted:
Feb 23, 2017
Last Update Posted:
Feb 23, 2017
Last Verified:
Feb 1, 2017
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Feb 23, 2017