Pilot Study of Suction as a Mechanism of IUD Expulsion With Concomitant Menstrual Cup Use

Sponsor
University of Colorado, Denver (Other)
Overall Status
Recruiting
CT.gov ID
NCT05254041
Collaborator
(none)
80
1
1
22.3
3.6

Study Details

Study Description

Brief Summary

This study will provide pilot data examining suction as a mechanism of IUD displacement with menstrual cup use. The investigator hypothesize that manufacturer-recommended menstrual cup insertion and removal by breaking the seal will result in 15% rate of IUD displacement/expulsion. The investigator will also use this data to explore variables associated with IUD displacement and menstrual cup use. By examining the role of suction as a possible mechanism of IUD displacement, this research will allow healthcare providers to better counsel patients who use IUDs regarding menstrual cup use. Having a better understanding of the mechanics of IUD displacement could lead to the development of strategies to prevent expulsion.

Condition or Disease Intervention/Treatment Phase
  • Other: Menstrual Cup Removal
N/A

Detailed Description

Intrauterine devices (IUDs) are a commonly used, highly effective form of long-acting, reversible contraception in the United States (US). IUD expulsions, or displacement of the IUD from the top of the uterine cavity occur approximately 5% of the time but can have significant consequences for patients such as unintended pregnancy and further need for health care services and costs. Limited data suggests that menstrual cup use with an IUD in place may be associated increased risk of IUD expulsion. Menstrual cups such as the DivaCup are reusable collection devices that are an increasingly popular alternative to tampons or sanitary pads in the US; they are more cost effective and more environmentally sustainable. The cup is placed in the vagina to create a vacuum seal to prevent leakage. This seal or suction should be released before cup removal. Two plausible mechanisms have been suggested to explain IUD expulsion in the setting of menstrual cup use: the suction created by the cup displaces the IUD, or the IUD strings are inadvertently pulled on during cup removal. No studies have examined the mechanics of IUD displacement. Additionally, there are no formal recommendations guiding patients and providers about concomitant IUD and menstrual cup use, including expulsion risk or strategies to prevent expulsions. Data are needed to not only better understand the mechanisms of IUD displacement with menstrual cup use, but to better guide the many patients who use both.

This study will address this knowledge gap by performing an exploratory study of the IUD displacement with menstrual cup insertion and removal, specifically looking at suction as a mechanism. The investigator will enroll fifty women presenting for IUD removal. Women will be screened for eligibility and participants will be excluded if they are unable to place and remove a menstrual cup, do not have visible IUD strings on exam, have a silicone allergy or sensitivity, or have an experimental IUD. After a screening pelvic exam and transvaginal ultrasound to measure the distance of the IUD from the top of the uterine fundus, the participant will be asked to place a menstrual cup as suggested by the manufacturer. Participants will then be instructed to remove the menstrual cup by breaking the suction or seal. A repeat transvaginal ultrasound will be done to re-measure the IUD location and quantify any displacement. Participants who did not have complete IUD expulsion with the first cup placement and removal will be instructed to replace the cup and then remove the cup without breaking the seal.

This study will provide pilot data examining suction as a mechanism of IUD displacement with menstrual cup use. The investigator hypothesize that manufacturer-recommended menstrual cup insertion and removal by breaking the seal will result in 15% rate of IUD displacement/expulsion. The investigator will also use this data to explore variables associated with IUD displacement and menstrual cup use. By examining the role of suction as a possible mechanism of IUD displacement, this research will allow healthcare providers to better counsel patients who use IUDs regarding menstrual cup use. Having a better understanding of the mechanics of IUD displacement could lead to the development of strategies to prevent expulsion.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
80 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Other
Official Title:
Pilot Study of Suction as a Mechanism of IUD Expulsion With Concomitant Menstrual Cup Use
Actual Study Start Date :
Feb 20, 2022
Anticipated Primary Completion Date :
Jun 30, 2023
Anticipated Study Completion Date :
Dec 30, 2023

Arms and Interventions

Arm Intervention/Treatment
Other: Mentrual Cup Removal

Menstrual Cup Removal.

Other: Menstrual Cup Removal
Participants will be asked to remove Menstrual cup by breaking the seal.

Outcome Measures

Primary Outcome Measures

  1. The rate of IUD displacement with manufacturer-recommended menstrual cup insertion and removal [12-18 months]

    The rate of IUD displacement measured by the frequency of IUDs that shift >1cm after manufacturer-recommended menstrual cup insertion and removal.

Secondary Outcome Measures

  1. The rate of IUD displacement measured by the frequency of IUDs that shift >1cm after manufacturer-recommended menstrual cup insertion and removal followed by insertion and removal the menstrual cup without breaking the seal. [12-18 months]

    The rate of IUD displacement measured by the frequency of IUDs that shift >1cm after manufacturer-recommended menstrual cup insertion and removal followed by insertion and removal the menstrual cup without breaking the seal.

Other Outcome Measures

  1. III. The proportion of subjects who report pulling on the menstrual cup stem before breaking the seal. [12-18 months]

    The proportion of subjects who report pulling on the menstrual cup stem before breaking the seal.

  2. III. The proportion of subjects who report feeling suction during menstrual cup removal. [12-18 months]

    The proportion of subjects who report feeling suction during menstrual cup removal.

  3. III. The proportion of subjects who report palpating the IUD strings during menstrual cup removal. [12-18 months]

    The proportion of subjects who report palpating the IUD strings during menstrual cup removal.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 45 Years
Sexes Eligible for Study:
Female
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Female

  • Between the ages of 18-45

  • Currently has an FDA approved IUD

  • Present to CWHC for IUD removal

Exclusion Criteria:
  • Known sensitivity or allergy to silicone

  • known active vaginal infection (yeast, bacterial vaginosis, untreated sexually transmitted infection)

  • IUD strings not visible

  • Positive pregnancy test

Contacts and Locations

Locations

Site City State Country Postal Code
1 Comprehensive Women's Health Center Denver Colorado United States 80230

Sponsors and Collaborators

  • University of Colorado, Denver

Investigators

  • Principal Investigator: Cara Clure, MD, University of Colorado, Denver

Study Documents (Full-Text)

None provided.

More Information

Additional Information:

Publications

None provided.
Responsible Party:
University of Colorado, Denver
ClinicalTrials.gov Identifier:
NCT05254041
Other Study ID Numbers:
  • 21-4267
First Posted:
Feb 24, 2022
Last Update Posted:
Mar 21, 2022
Last Verified:
Mar 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No

Study Results

No Results Posted as of Mar 21, 2022