Loupe-Based Intraoperative Fluorescence Imaging

Sponsor
Guoqiang Yu (Other)
Overall Status
Recruiting
CT.gov ID
NCT04780009
Collaborator
Bioptics Technology LLC (Other), National Cancer Institute (NCI) (NIH), Kentucky Small Business Innovation Research / Small Business Technology Transfer (SBIR/STTR) (Other)
20
1
56.4
0.4

Study Details

Study Description

Brief Summary

Glioblastoma multiforme (GBM) and anaplastic astrocytoma (AA) are the most common primary malignant brain tumors. Survival of patients with these brain tumors is directly related to the extent of resection. Consequently, a great deal of effort has been directed at developing techniques and technologies that allow more extensive, safe resections.

This study will test a loupe-based wearable device in the clinical setting and compare its accuracy with a large operative microscope to identify tumor tissues. Postoperative histopathological analysis on tumor tissues will be used as gold standards for comparison. The outcome from this study will be a low-cost, miniaturized, easy-to-operate, loupe-based fluorescence imaging device for intraoperative guidance of brain tumor resection with the same level of accuracy as the large microscope.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    This is a prospective, observational study to compare the measurement accuracies of a wearable loupe-based device and the large microscope against the gold standards of postoperative histopathological analysis on tumor tissues.

    At the induction of anesthesia, patients will receive 5 mg/kg of intravenous sodium 5-aminolevulinic acid (5-ALA) or fluorescein. Surgery will be performed under the guidance of the operative fluorescence microscope (PENTERO with fluorescence kit + YELLOW 560, Carl Zeiss) or (PENTERO 900 + BLUE 400, Carl Zeiss). The operating room light will be dimmed for optimum reproduction of the fluorescent light. Tumor removal will be continued until no fluorescent area is visualized. To evaluate the accuracy of the device in the identification of tumor tissue, six samples will be biopsied from the tumor resection margin for each patient; three in the fluorescent area and three in the non-fluorescent area for the assessment of positive and negative predictive values of the devices, respectively. These biopsied tissues will be taken to the clinical pathology laboratory for the standard histological analysis.

    To compare the accuracy of the two imaging systems in identifying tumor tissues, the tumor resection area will be visually observed by the surgeon and video recorded using the new loupe-based device at two time points (at least): immediately before and immediately after tumor removal. Additional fluorescence images may be taken during surgery as long as the surgical workflow is not impacted. Moreover, the four fresh biopsies (2 in the fluorescent area and 2 in the non-fluorescent area) taken from the tumor margin based on the operative microscope diagnosis will also be examined intraoperatively by the loupe-based device to determine whether they are fluorescent or non-fluorescent.

    To discriminate between clear tumor tissue and the peritumoral areas, the postoperative histological analysis of the biopsied samples taken from the tumor margins will be classified on the basis of the current 2016 WHO classification. The neuropathologist will be blinded to the fluorescence characteristics of the biopsied samples.

    Study Design

    Study Type:
    Observational
    Anticipated Enrollment :
    20 participants
    Observational Model:
    Case-Only
    Time Perspective:
    Prospective
    Official Title:
    Loupe-Based Intraoperative Fluorescence Imaging for the Guidance of Brain Tumor Surgery
    Actual Study Start Date :
    Nov 17, 2017
    Anticipated Primary Completion Date :
    Aug 1, 2022
    Anticipated Study Completion Date :
    Aug 1, 2022

    Outcome Measures

    Primary Outcome Measures

    1. Positive Predictive Value (PPV) [1 day]

      The proportion of samples that are histologically confirmed as tumor-positive among all fluorescent samples will be calculated.

    2. Negative Predictive Value (NPV) [1 day]

      The proportion of samples that are histologically confirmed as tumor-negative among all fluorescent samples will be calculated.

    Secondary Outcome Measures

    1. Residual Tumor [1 day]

      The proportion of positive results among all tumors with residual as well as the proportion of negative results among tumors without residual will be calculated relative to post-operative histopathological analysis.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 90 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • adults with brain malignant gliomas undergoing resection

    • at least 18 years of age

    • able to understand the consent

    Exclusion Criteria:
    • pregnant women

    • under 18 years of age

    • patients undergoing emergency surgery

    • inability to give consent due to dysphagia or language barrier

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 University of Kentucky Lexington Kentucky United States 40536

    Sponsors and Collaborators

    • Guoqiang Yu
    • Bioptics Technology LLC
    • National Cancer Institute (NCI)
    • Kentucky Small Business Innovation Research / Small Business Technology Transfer (SBIR/STTR)

    Investigators

    • Principal Investigator: Guoqiang Yu, PhD, University of Kentucky

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Guoqiang Yu, Professor, University of Kentucky
    ClinicalTrials.gov Identifier:
    NCT04780009
    Other Study ID Numbers:
    • MCC-17-0605-F1V
    • R41CA243600-01
    First Posted:
    Mar 3, 2021
    Last Update Posted:
    Mar 4, 2022
    Last Verified:
    Mar 1, 2022
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No