Lung Ultrasound Safety in Humans

Sponsor
Massachusetts General Hospital (Other)
Overall Status
Unknown status
CT.gov ID
NCT02453724
Collaborator
(none)
200
1
24
8.3

Study Details

Study Description

Brief Summary

The purpose of this study is to investigate if diagnostic ultrasound as it is routinely performed in humans causes lung hemorrhage significant enough to appear on thoracic CT. The investigators' hypothesis is that diagnostic lung ultrasound will not cause lung hemorrhage in humans. Damage to the lung in animal models has been shown to be mechanical rather than thermal in nature and evidence suggests that this injury is likely not from inertial cavitation but from alveolar resonance. Models of the alveolar resonance theory predict that hemorrhage should not happen in adult human lungs if the ultrasound frequency is higher than 1.69 MHz and mechanical index (MI) is less than 1.9 which is maintained with standard scanning protocol for thoracic ultrasound. A previous human study showed no gross macroscopic lung hemorrhage in patients undergoing transesophageal echocardiography with pressures of 2.4 MPa and MI 1.3 with exposure durations ranging 7-68 minutes.

The investigators propose to perform a routine lung ultrasound exam on patients who are scheduled to undergo chest computed tomography evaluation for pulmonary embolus as part of their routine care. The ultrasound will be performed immediately prior to CT imaging and markers will be placed on the patients chest to ensure the correct lung tissue is being evaluated. There will be two sham markers so the radiologist will be blinded to which tissue had ultrasound applied and which did not. The CT scan will then be evaluated per routine and also to see if there are signs of microscopic or macroscopic hemorrhage under the skin markers.

Condition or Disease Intervention/Treatment Phase
  • Device: Observation for safety

Detailed Description

This is a prospective, observational cohort study of emergency department patients designed to assess for radiographic changes suggestive of lung hemorrhage after thoracic ultrasound.

The investigators will only approach patients scheduled for CT scan as part of their routine care in the emergency department for enrollment. Only patients > 18 years old. Patients who are not english speaking will only be consented if there is a medical interpreter immediately available who can be approached for informed consent.

Patients who have given informed consent will have a lung ultrasound performed by a study physician immediately prior to CT scan - after the patient has been transported to the ED radiology area but before the CT scan is performed. The lung ultrasound will be performed using a low frequency probe (2-5 MHz). Of the four standard positions used in lung ultrasonography (Zone 1, 4, 5, 8; see Image 1 below), study ultrasonography will be performed on only two.

The two positions selected for use will be chosen immediately prior to ultrasound performance by the performing physician using a simple binary random number generator for each lung. This will ensure that one zone is subjected to ultrasound on each lung. A small radio-opaque button will be placed overlying all four zones (i.e., those exposed and those not exposed) in the standard position of the ultrasound footprint (ie where the ultrasound was or would have been performed) and then the patient will undergo the CT scan according to standard radiology department protocols.

The CT scan will then be reviewed for signs of alveolar hemorrhage in the lung tissue immediately adjacent to the radio-opaque button. Radiologists will be blinded as to which buttons abut zones exposed to ultrasound or not exposed. Any findings will be immediately reported to the patient's care team and the patient and standard protocols for treatment and observation will be followed.

The investigators have calculated the need to enroll 200 patients to observe a 7% range above and below previously published numbers of incidental findings on chest CT scan.

Study Design

Study Type:
Observational
Anticipated Enrollment :
200 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Lung Ultrasound Safety in Humans
Study Start Date :
Aug 1, 2015
Anticipated Primary Completion Date :
Aug 1, 2017
Anticipated Study Completion Date :
Aug 1, 2017

Outcome Measures

Primary Outcome Measures

  1. Micro or macroscopic lung parenchymal hemorrhage [At enrollment]

    The investigators will perform the ultrasound just prior to chest computed tomography enrollment so that there is minimal time delay between the ultrasound performance and assessment of the lung parenchyma.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • All patients greater than 18 years of age scheduled to receive chest tomography scans for pulmonary embolus.
Exclusion Criteria:
  • None.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Massachusetts General Hospital Boston Massachusetts United States 20114

Sponsors and Collaborators

  • Massachusetts General Hospital

Investigators

  • Principal Investigator: Vicki E Noble, MD, Massachusetts General Hospital

Study Documents (Full-Text)

None provided.

More Information

Publications

Responsible Party:
Vicki Noble, MD, Director, Division of Emergency Ultrasound, Massachusetts General Hospital
ClinicalTrials.gov Identifier:
NCT02453724
Other Study ID Numbers:
  • 2013P002671
First Posted:
May 25, 2015
Last Update Posted:
Mar 18, 2016
Last Verified:
Mar 1, 2016
Keywords provided by Vicki Noble, MD, Director, Division of Emergency Ultrasound, Massachusetts General Hospital
Additional relevant MeSH terms:

Study Results

No Results Posted as of Mar 18, 2016