VALIDIRM: Validation and Implementation of 3T MRI Research Protocols

Sponsor
Institut National de la Santé Et de la Recherche Médicale, France (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT04866940
Collaborator
(none)
230
1
72

Study Details

Study Description

Brief Summary

The Philips 3T imager installed on the Pavillon Baudot site is an imager dedicated solely to research. It is not located in hospital premises but in INSERM premises for which an authorization for biomedical research has been granted. This equipment is part of the Technical Platform of the UMR 1214 ToNIC whose main objective is the study of the human brain and the main pathologies that affect it.

MRI is an evolving technique, which is used in many research projects. Our technical platform must follow these developments and remain at the cutting edge. One of the essential services of our technical platform is to help set up research protocols and validate acquisition sequences. This development activity is therefore located upstream of research projects involving clinical or fundamental applications. The fact that we can provide our users with a regulatory framework to carry out these development tests for their Research Involving Human Subjects project is a necessity for our research support activity.

This study aims to provide a generic framework to test the feasibility of MRI sequences requested within the framework of protocols, but also to optimize MRI acquisition sequences already in place, to improve image quality and reduce artifacts that can degrade the quality of the images obtained.

In France, there are just over 35 centers with MRI dedicated to research and therefore with a validation protocol allowing them to validate their sequences.

Condition or Disease Intervention/Treatment Phase
  • Other: Sequences test
N/A

Detailed Description

This is a prospective monocentric research on major participants (healthy and patients). The optimization of the sequences will be carried out in an incremental way from one control to the other: for each control, several sequences will be carried out for an acquisition time not exceeding one hour of cumulated acquisition (i.e. one hour and a half including the installation and the delays between the sequences). Each sequence lasts between 5 and 20 minutes.

At the end of the examination, the images obtained will be evaluated jointly by an expert neuroradiologist and a research engineer specialized in image analysis according to the criteria mentioned above. This analysis will make it possible to determine the parameters to be modified to improve image quality and to define the acquisition parameters for the next test.

As soon as a sequence is considered optimal, it will be tested on a small number of healthy controls (≈ 5) to ensure interindividual reproducibility of image quality parameters, and then if necessary in the presence of pathology in a few patients (≈ 5).

Study Design

Study Type:
Interventional
Anticipated Enrollment :
230 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Screening
Official Title:
Validation and Implementation of 3T MRI Research Protocols
Anticipated Study Start Date :
Apr 1, 2021
Anticipated Primary Completion Date :
Apr 1, 2027
Anticipated Study Completion Date :
Apr 1, 2027

Arms and Interventions

Arm Intervention/Treatment
Experimental: Sequence validation

This research aims to provide a generic framework to test the feasibility of MRI sequences requested as part of protocols, but also to optimize MRI acquisition sequences already in place, to improve image quality and reduce artifacts that can degrade the quality of images obtained.

Other: Sequences test
the realization of preliminary acquisitions to validate the feasibility of clinical or cognitive research protocols

Outcome Measures

Primary Outcome Measures

  1. in general [at the end of studies ((i.e. one hour and a half including the installation and the delays between the sequences). Each sequence lasts between 5 and 20 minutes.]

    optimization of parameters acquisition in order to suppress artefact

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Male or female, 18 years of age or older

  • Ability to cooperate and remain motionless for up to 1 hour (and lying down for 1.5 hours)

  • Ability to understand the instructions given

  • Subject who has given written and informed consent prior to any examination required by the research)

  • Subject affiliated to a social security system or benefiting from an equivalent system

Exclusion Criteria:
  • Persons deprived of liberty by judicial or administrative decision

  • Psychiatric disorders, disorders of cognitive functions, not allowing the realization of the MRI

  • Protected adults (subject to a measure of legal protection) or unable to express their consent

  • Subject with Contraindications to MRI

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • Institut National de la Santé Et de la Recherche Médicale, France

Investigators

  • Principal Investigator: ¨PAYOUX Pierre, Pr, Institut National de la Santé Et de la Recherche Médicale, France

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Institut National de la Santé Et de la Recherche Médicale, France
ClinicalTrials.gov Identifier:
NCT04866940
Other Study ID Numbers:
  • C20-28
First Posted:
Apr 30, 2021
Last Update Posted:
Apr 30, 2021
Last Verified:
Apr 1, 2021
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No

Study Results

No Results Posted as of Apr 30, 2021