Comparative Study in Measuring Anterior Chamber Depth

Sponsor
Assiut University (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT04816266
Collaborator
(none)
50
24

Study Details

Study Description

Brief Summary

Measuring parameters of anterior segment of the eye accurately is important for diagnosing variety of diseases and for cataract surgeries, glaucoma, refractive surgeries and post-operative follow-up. One of the anterior segment parameters is the anterior chamber depth.

The anterior chamber depth (ACD) measurement provides valuable information in different fields in ophthalmology. Firstly, it is important for the new theoretical biometric formulas used to calculate the power of intraocular lenses (IOLs) .Secondly, phakic IOL implantation requires precise ACD measurement for both surgical planning and IOL power calculation. Thirdly, the ACD is also implicated as a screening risk factor for glaucoma. Additionally, precise ACD measurement is thought to be important to the accurate determination of the optic zone ablation diameter for keratorefractive surgery, as well as for the analysis of postoperative ACD changes.

Different technologies are used in measurement of the anterior chamber depth Such as pentacam and iol maste

Condition or Disease Intervention/Treatment Phase
  • Device: Iol master
  • Device: Pentacam

Detailed Description

IOL master :

Optical biometry by the IOL Master was introduced in the United Kingdom in 1999.Its technology is based on laser interfer-ometry with partial coherent light, termed as Partial Coherence Interferometry (PCI).The device uses the principle of PCI to measure the axial length of the eye.While uses a slit-beam photo-graphic technique for ACD measurements For keratometry measurement, six light spots are projected hexagonally on the cornea .The device records the reflection of these images measuring the separation of the opposite pairs of light spots and calculating the corneal radii and toroidal surface curvature. The mean of the taken measurements is considered the corneal power . The displayed K1 and K2 represent the average keratometry values at two major perpendicular meridians .For ACD measurement, the IOL Master directs a slit beam of light 0.7mm wide through the anterior segment at an angle of 38ยบ to the visual axis.The internal software measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the ACD . The device takes five ACD measurements in rapid succession; the mean of these readings are taken as the ACD value . For WTW measurement, a digital grey-scale photograph of the anterior surface of the eye is taken after focusing on the iris. The limbus is then detected automatically and the WTW distance is measured

Pentacam :

The Pentacam obtains images of the anterior segment by a rotating Scheimpflug blue Light Emitting Diode (LED) with a wavelength of 475nm. It acquires 50 images in a duration of approximately two seconds. It extracts about 2,760 true elevation points from the obtained images which in turn generates 1 38,000 true elevation points for the both front and back corneal surfacesand from limbus to limbus, including the central part of the cornea . There for, it calculates k-readings of the cornea. The Pentacam HR calculates ACD from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens . Horizontal WTW was measured by manual placement of callipers on the Scheimpflug image of the horizontal plane of the examined eye; callipers are placed on the corneo-scleral junction then a line is automat-ically drawn between the two points . The length of this line represents the WTW value

Study Design

Study Type:
Observational
Anticipated Enrollment :
50 participants
Observational Model:
Case-Only
Time Perspective:
Cross-Sectional
Official Title:
Comparative Study Between Pentacam and IOL Master in Measuring Anterior Chamber Depth
Anticipated Study Start Date :
Apr 1, 2021
Anticipated Primary Completion Date :
Apr 1, 2022
Anticipated Study Completion Date :
Apr 1, 2023

Arms and Interventions

Arm Intervention/Treatment
Myopic patients

Device: Iol master
Iol master measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the anterior chamber depth

Device: Pentacam
The Pentacam HR calculates Anterior chamber depth from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens

Hypermetropic patients

Device: Iol master
Iol master measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the anterior chamber depth

Device: Pentacam
The Pentacam HR calculates Anterior chamber depth from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens

Emmetropic people

Device: Iol master
Iol master measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the anterior chamber depth

Device: Pentacam
The Pentacam HR calculates Anterior chamber depth from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens

Outcome Measures

Primary Outcome Measures

  1. Comparison between values of anterior chamber depth obtained by different devices [One year]

    Measuring Anterior chamber depth by Pentacam and iol master in eyes with different refractive errors

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 40 Years
Sexes Eligible for Study:
All
Inclusion Criteria:
  • presenting for glasses

  • asking for refractive surgery

Exclusion Criteria:
  • severe corneal scarring or opacity

  • patients with corneal dystrophy

  • patients with keratoconus

  • patients with previous ocular surgery

  • patients with ocular trauma

  • patients with uveitis

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • Assiut University

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Engy Adel Fayez Demian, Principal investigator, Assiut University
ClinicalTrials.gov Identifier:
NCT04816266
Other Study ID Numbers:
  • Anterior chamber depth
First Posted:
Mar 25, 2021
Last Update Posted:
Mar 25, 2021
Last Verified:
Mar 1, 2021
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Mar 25, 2021