MANGO: MRI Hypoxia Study for Glioblastoma Multiforme (GBM) Radiation Therapy

Sponsor
University of Sydney (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT05500612
Collaborator
The Brain Cancer Group (Other)
20
2
36
10
0.3

Study Details

Study Description

Brief Summary

This study is designed to evaluate the role of Oxygen Enhanced (OE) Magnetic resonance imaging (MRI) and Blood Oxygenation Level Dependent (BOLD) MRI in detecting regions of hypoxic tumour and to evaluate their use as imaging methods to selectively deliver targeted radiotherapy to regions of aggressive disease.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    The ability to image tumour hypoxia at diagnosis and prior to radiotherapy is extremely important to appropriately adapt radiotherapy plans such that to selectively deliver higher doses of radiation to those more aggressive tumour subregions, thereby improving the chances to achieve better local tumour control. Preoperative imaging of tumour hypoxia also offers the opportunity for 'supra-marginal resections' in surgical planning beyond current neurosurgical standard of care. Additionally, accurately identifying regions of tumour hypoxia harbouring tumour progression at follow up is fundamental in patient follow-up, allowing multidisciplinary teams to more confidently intervene at an earlier stage of tumour recurrence and personalise therapy tailored to the tumour's response to treatment. Routine imaging of tumour hypoxia is currently challenging, as it requires [18F]-Fluoromisonidazole (18F-FMISO PET) imaging, which is not available in the majority of clinical centres. Today, the availability of accelerated quantitative MRI sequences on clinical MRI systems could enable quantification of tumour hypoxia without putting an unfeasible burden on patients' scan sessions. The next frontier in radiotherapy treatment will use these techniques to identify hypoxic tumour tissues and personalise treatments to the patient's unique tumour biology, maximising the probability of tumour control.

    This clinical study will acquire additional images of brain cancer patients. The images will not change the patient's treatment. This study is designed to evaluate the role of oxygen enhanced (OE) MRI and BOLD MRI in detecting regions of hypoxic tumour and to evaluate their use as imaging methods to selectively deliver targeted radiotherapy to regions of aggressive disease.

    Study Design

    Study Type:
    Observational
    Anticipated Enrollment :
    20 participants
    Observational Model:
    Case-Only
    Time Perspective:
    Prospective
    Official Title:
    Magnetic Resonance Imaging of Hypoxia for Radiation Treatment Guidance in Glioblastoma Multiforme (MANGO)
    Anticipated Study Start Date :
    Aug 1, 2022
    Anticipated Primary Completion Date :
    Aug 1, 2024
    Anticipated Study Completion Date :
    Aug 1, 2025

    Outcome Measures

    Primary Outcome Measures

    1. Determination of spatial correlation of hypoxic tumour volume between Magnetic resonance imaging (MRI) and [18F]-Fluoromisonidazole (18F-FMISO) MRI [1 year]

      Spatial correlation between hypoxic tumour volume determined with MRI and 18F-FMISO will be evaluated via measurements of Dice similarity coefficient. Dice similarity coefficients > 0.9 will be considered a strong spatial correlation. Quantitative correlation of voxel-wise levels of hypoxia will be evaluated via measurement of the Spearman's/Pearson's correlation coefficient. Correlation coefficients > 0.7 will be considered a strong correlation.

    Secondary Outcome Measures

    1. Repeatability of voxel-wise levels of hypoxia in the tumour [1 year]

      Repeatability of voxel-wise levels of hypoxia in the tumour will be assessed by measurements of intraclass correlation coefficient (ICC).27 ICC values > 0.9 reflect excellent repeatability, good between 0.75 and 0.9, moderate between 0.5 and 0.75, and poor < 0.5. Additionally, similarity between the hypoxia tumour volume (HTV) defined with the MRI biomarker at the two timepoints will be assessed via calculation of Dice similarity coefficient. Dice similarity coefficients > 0.9 will be considered a strong correlation.

    2. The predicted patient outcomes of the biologically-adapted Radiotherapy (RT) plan will be compared with the actual patient outcomes [1 year]

      The predicted patient outcomes of the biologically-adapted RT plan will be compared with the actual patient outcomes following conventional treatment, by using metrics including tumour control probability (TCP) and toxicity measurement to organs at risks and healthy brain (including equivalent uniform dose). Success for this objective will be achieved if the biologically-adapted RT plans result in improved TCP by at least 10% for all patients over conventional treatment, while toxicity metrics remain similar.

    3. Correlation between the percentage of hypoxic tumour volume and clinical outcome [1 year]

      Correlation between the percentage of hypoxic tumour volume and clinical outcome will be evaluated by means of hazard ratio obtained from Cox regression. A hazard ratio > 1 (p<0.05) will indicate that the hypoxic tumour volume increase from 13 weeks post chemoradiation therapy (CRT) and recurrence is associated with worst Overall Survival (OS) and Progression Free Survival (PFS).

    4. Correlation between the percentage change of hypoxic tumour volume during treatment and clinical outcome [1 year]

      Correlation between the percentage change of hypoxic tumour volume during treatment and clinical outcome will be evaluated by means of hazard ration obtained from Cox regression. A hazard ratio > 1 (p<0.05) will indicate that the increase in hypoxic tumour volume during treatment is associated with worse OS.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Suspected high-grade glioma (HGG) / glioblastoma multiforme (WHO grade IV) at initial radiological examination

    • Eastern Cooperative Oncology Group (ECOG) performance status score of 0-2

    • Available for scanning on two separate days

    Exclusion Criteria:
    • Women lactating, pregnant or of childbearing potential who are not willing to avoid pregnancy during the study

    • Patients with a history of severe renal disease(s) (eGFR <20) that cannot tolerate gadolinium chelate contrast agents.

    • Geographically remote patients unable to agree to imaging schedule

    • Patients who have received anti - vascular endothelial growth factor (anti-VEGF) monoclonal antibody therapy the 3 months prior to recruitment

    • Patients with a history of psychological illness or condition such as to interfere with the patient's ability to understand the requirements of the study.

    • Patients with significant cardiac or pulmonary disease including cardiac arrythmias or Chronic Obstructive Pulmonary Disease (COPD) that are unable to tolerate high flow O2 for oxygen contrast.

    • Patients taking carbonic anhydrase inhibitors (Acetazolamide)

    • History of glaucoma

    • Any implant, foreign body, 3 Tesla (3T) MRI incompatible device, or other contraindication to MRI imaging.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 North Shore Private Hospital St Leonards New South Wales Australia 2065
    2 Royal North Shore Hospital St Leonards New South Wales Australia 2065

    Sponsors and Collaborators

    • University of Sydney
    • The Brain Cancer Group

    Investigators

    • Principal Investigator: Caterina Brighi, University of Sydney

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    University of Sydney
    ClinicalTrials.gov Identifier:
    NCT05500612
    Other Study ID Numbers:
    • ETH11794
    First Posted:
    Aug 15, 2022
    Last Update Posted:
    Aug 22, 2022
    Last Verified:
    Aug 1, 2022
    Individual Participant Data (IPD) Sharing Statement:
    Yes
    Plan to Share IPD:
    Yes
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Aug 22, 2022