Multi-center Study of Artificial Intelligence Model for Gadolinium-based Contrast Agent Reduction in Brain MRI (MAGNET)

Sponsor
Beijing Tiantan Hospital (Other)
Overall Status
Recruiting
CT.gov ID
NCT05754476
Collaborator
(none)
3,000
1
69.1
43.4

Study Details

Study Description

Brief Summary

MAGNET is a multi-center and prospective study to minimize Gadolinium-based Contrast Agent (GBCA) combining novel artificial intelligence (AI) methods with pre-contrast images and/or low-dose images to synthesize virtual contrast-enhanced T1 (vir-T1c) images, based on a large clinical and MRI database and subsequently validated for its clinical value. MRI examinations for patients included T1-weighted images (T1WI) before and after contrast agent administration and at two dose levels: low-dose (10% or 25%) and full-dose (100%), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and diffusion-weighted imaging sequences (DWI) and the computed apparent diffusion coefficient (ADC), all either acquired three dimensional [3D] or two dimensional [2D]). The standard dose of intravenous gadolinium contrast agent was 0.1mmol/kg(body weight) by manual injection or automatic injection with a high-pressure syringe at a flow rate of 4mL/s.The sequence parameters used for the 3DT1WI scans must be consistent, and the standard for intravenous injection of gadolinium contrast agent is 0.1mmol/kg (body weight), administered either manually or automatically with a high-pressure syringe at a rate of 4mL/s.

Additionally, arterial spin labeling (ASL), amide-proton transfer chemical exchange saturation transfer (APT-CEST), susceptibility-weighted imaging (SWI), or quantitative susceptibility mapping (QSM) can be acquired at the same time if the conditions permit.

Condition or Disease Intervention/Treatment Phase
  • Other: Low-dose GBCA levels

Detailed Description

MRI with GBCA is an indispensable part of imaging exams for brain disease diagnosis. Generally, GBCA is safe, with a few mild side effects since GBCAs received FDA approval in 1989. There are numerous issues that challenge the current practice of widespread use of GBCA. GBCA can trigger nephrogenic systemic fibrosis(NSF) under particular circumstances, cause allergic reactions, may increase the risk of fetal death, and accumulate in the brain such as the dentate nucleus and globus pallidus. Efforts need to be made to reduce dose while still maintaining diagnostic capabilities. Artificial intelligence (AI) techniques have shown great potential in medical fields. Deep learning (DL), a branch of AI, has been applied to image segmentation, computer-aided diagnosis, and reduce GBCA dose.

This study intends to build a prospective brain MRI dataset including patients with suspected or known brain abnormalities to minimize the use of GBCA. Then train DL models to process pre-contrast images and/or low-dose T1 images to predict virtual contrast-enhanced T1 (vir-T1c) images, taking the full-dose images as the reference standard. Later quantitatively and qualitatively evaluating and comparing vir-T1c images from DL models about clinical diagnostic performance, focusing on lesion detection, diagnosis, and therapy, to explore a DL model universal, provide enhanced images faster and more convenient in clinical practice. To minimize the use of GBCA, we will:

  1. Use novel artificial intelligence (AI) methods with pre-contrast images including conventional (T1WI, T2WI, FLAIR, DWI/ADC), new physiological MRI techniques (ASL, APT-CEST, SWI/QSM) by adding physiological information from perfusion as well as metabolic and susceptibility imaging, and/or low-dose images (10% or 25%) to synthesize vir-T1c images;

  2. Quantify when (in which patients and at what follow-up times) GBCA can be omitted or minimized without influencing brain disease diagnosis and treatment evaluation for doctor raters and therefore patient prognosis.

This study does not limit manufacturers including 1.5T and 3.0T scanners, or kinds of GBCAs.

Study Design

Study Type:
Observational
Anticipated Enrollment :
3000 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Multi-center and Prospective Cohort Study of Artificial Intelligence Model for Gadolinium-based Contrast Agent Reduction in Brain MRI (MAGNET)
Actual Study Start Date :
Mar 29, 2019
Anticipated Primary Completion Date :
Dec 31, 2023
Anticipated Study Completion Date :
Dec 31, 2024

Arms and Interventions

Arm Intervention/Treatment
Brain Diseases

This study does not limit the kinds of brain diseases. The cohort includes patients with suspected or known brain diseases including tumors, vascular disorder, inflammatory disease, neurodegenerative diseases and trauma, follow-up, routine brain, and others requiring MRI exams with GBCAs.

Other: Low-dose GBCA levels
MRI examinations for patients at two dose levels: low-dose (10% or 25%)can be chosen.

Outcome Measures

Primary Outcome Measures

  1. quantitative metrics [after training and applying of the proposed deep learning model, an average of 1 year]

    To quantitatively describe the discrepancies between the vir-T1c and the full-dose images by measuring the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). The PSNR measures the voxelwise difference and the PSNR range is between -1 and 1. The SSIM compares nonlocal structural similarity and the minimum value of PSNR is 0. The metrics will be reported in separate(e.g.,SSIM, 0.90; PSNR,42 in vir-T1c, SSIM, 0.94; PSNR,45 in full-dose images).

  2. qualitative assessments [after training and applying of the proposed deep learning model, an average of 15 months]

    To qualitatively describe discrepancies between the vir-T1c and full-dose images by evaluating enhancement degree, homogeneity, and pattern. Firstly, zero indicates no intracranial or non-enhancing lesion. For enhancement degree, 1 indicates mild enhancement, 2 indicates moderate enhancement, and 3 indicates clear enhancement. For enhancement homogeneity, 1 indicates heterogeneous enhancement, 2 indicates mildly heterogeneous enhancement, and 3 indicates homogeneous enhancement. For enhancement pattern, 1 indicates mass enhancement(proportion enhancement more than 50%), 2 indicates nodular enhancement (proportion enhancement less than or equal to 50%), 3 indicates ring enhancement, 4 indicates linear enhancement, and 5 indicates other enhancement.

Secondary Outcome Measures

  1. clinical effects [after training and applying of the proposed deep learning model, an average of 18 month]

    To describe whether vir-T1c images combing other sequences affect diagnosis or treatment according to evaluation of neuroradiologist and neurologist from 1 to 5 scores. Zero indicates enhancement error and can not be used. 1 indicates non-diagnostic. 2 indicates affecting diagnosis or treatment significantly. 3 indicates affecting diagnosis or treatment moderately. 4 indicates no affecting diagnosis or treatment almost. 5 indicates no affecting diagnosis or treatment completely.

Eligibility Criteria

Criteria

Ages Eligible for Study:
N/A and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  1. Patients with suspected or known brain diseases including tumors, vascular disorders, inflammatory diseases, neurodegenerative diseases and trauma, follow-up, routine brain, and others requiring MRI exams with GBCAs.

  2. Informed written consent obtained from the patient, and/or patient's parent(s), and/or legal representative.

Exclusion Criteria:
  1. Patients with contraindications to MR examination.

  2. Patients with incomplete MRI data and obvious image artifacts.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Beijing Tiantan Hospital Beijing Beijing China 100053

Sponsors and Collaborators

  • Beijing Tiantan Hospital

Investigators

  • Principal Investigator: Yaou Liu, PhD, Study Principal Investigator

Study Documents (Full-Text)

More Information

Publications

Responsible Party:
Yaou Liu, Professor, Beijing Tiantan Hospital
ClinicalTrials.gov Identifier:
NCT05754476
Other Study ID Numbers:
  • KY-2021-184-04
First Posted:
Mar 3, 2023
Last Update Posted:
Mar 3, 2023
Last Verified:
Mar 1, 2023
Individual Participant Data (IPD) Sharing Statement:
Yes
Plan to Share IPD:
Yes
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Mar 3, 2023