NEOVAS: Neck Evolution With Ovation in Spain

Sponsor
DGM Vascular (Other)
Overall Status
Recruiting
CT.gov ID
NCT05823519
Collaborator
Hospital Universitario Central de Asturias (Other)
120
9
55
13.3
0.2

Study Details

Study Description

Brief Summary

This is a multicenter, observational, prospective, single arm registry using Ovation Alto Endograft. A minimum of 50 up to a maximum of 120 subjects undergoing endovascular repair with Ovation Alto endograft will be enrolled and followed procedurally to discharge, at 1month, 6 months, 1 year and yearly afterward up to 3 years. This registry of Ovation Alto endograft will provide further assessment to confirm continuing safety and effectiveness of the graft and to confirm the stability of the neck diameter over time when treated with this device.

Condition or Disease Intervention/Treatment Phase
  • Device: Endologix Ovation Alto Endograft

Detailed Description

Abdominal Aortic Aneurysm (AAA) is a widespread disease with a high mortality rate in case of ruptures, with a sizable number of patients dying before a diagnosis is made. Approximately 32.000 patients are newly diagnosed with AAA and about 44.000 repair procedures are performed in the US every year. It is estimated that up to 2.000.000 subjects are living with an undiagnosed AAA with a greater incidence in the elderly population >65 years. Risk factors include smoking, hypertension, hypercholesterolemia, gender (men/women ratio 5:1) and family history (15-20%) increase risk amongst first degree relatives. The rupture risk increases with age and concomitant hypertension as well as current tobacco use and presence of other cardio-vascular diseases. AAA is clinically defined as a focal dilatation of the aorta causing a diameter increase of >50% of the expected normal diameter. Although any artery may develop an aneurysm, they are most commonly observed in the infrarenal abdominal aorta, thoracic aorta, popliteal artery and common iliac artery. The concomitants risks related to aneurysms are rupture and thrombus migration. Aneurysms slowly and continually grow in size leading to the aneurysm bursts. The larger an aneurysm becomes, the likelihood of eventual rupture may appear. The natural outcomes of aortic aneurysms is to enlarge and rupture. Other potential complications of the aneurysm include compression of adjacent organs which may result in aortoenteric fistula, or aortocaval fistula. If the thrombus embolizes and flows down the blood stream, this can induce acute or chronic arterial obliteration of the lower limbs.The risk of rupture is weighed against the risk of perioperative morbidity. The United Kingdom Small Aneurysm trial (UKSAT) reported 103 aneurysm ruptures in 2,257 subjects over a period of seven years, with an annual rupture rate of 2.2%. The decision to treat a patient that presents with an asymptomatic aneurysm is primarily dependent upon the size of the aneurysm. Current Society for Vascular Surgery (SVS) practice guidelines recommend surveillance for most subjects with a fusiform AAA in the range of 4.0 to 5.4cm in maximum diameter; therefore, surgical repair of abdominal aneurysms of 5.5 cm or greater in diameter is recommended in healthy subjects, as it is repair of saccular aneurysms. With the development of endovascular treatment options in recent years, treatment of AAA has become a viable option for patients with a high pre-operative risk. Endovascular Aneurysm Repair (EVAR) has become the treatment strategy of choice for AAA. Nowadays, the most important limit to the effectiveness of this technique is represented by complex anatomical situations, especially regarding the morphology of the proximal sealing zone. In previously published studies, the use of EVAR outside the specific instructions for use (IFU) of the devices for patients with challenging proximal aortic necks yielded a non-negligible rate of immediate complications and re-interventions. The Ovation iX and Alto endografts represent a new technical step in EVAR. This new device separates fixation from sealing: fixation is guaranteed by suprarenal stent and anchors, while sealing is ensured by inflatable rings filled with a low-viscosity, non-embolic, radiopaque fill polymer. This unique characteristic allows this graft to isolate aortic neck from blood pressure without radial force, with the result of very low ratios of Type 1 Endoleaks and absence aortic neck growing. The presence of the polymer-filled network also allows the graft to conform to the patient's aortic neck, providing precise and reliable sealing in a great variety of anatomies. Different from common stent-graft platforms, separation between fixation and sealing ensures that stent and fabric do not compete in the Ovation endograft for the same space within the shaft, and an ultra-low-profile delivery system can be achieved, allowing the treatment of patients presenting a wide range of iliac access.

Study Design

Study Type:
Observational
Anticipated Enrollment :
120 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Neck Evolution With Ovation in Spain
Actual Study Start Date :
Jun 1, 2022
Anticipated Primary Completion Date :
Jan 1, 2024
Anticipated Study Completion Date :
Jan 1, 2027

Arms and Interventions

Arm Intervention/Treatment
SINGLE Arm

Observational, Multicenter, Prospective, single arm registry study with consecutive, eligible patient enrollment at each site. Subjects will be followed procedurally to discharge, and as per institutional standard of care thereafter through to 3 years (total follow-up commitment), with follow up including Computed tomography angiography (CTA) study and Case Report Form data at 1 month, 6 months, 1 years, 2 years and 3 years, closing at this time the study primary endpoint.

Device: Endologix Ovation Alto Endograft
Implantation of aorto-bisiliac ALTO endograft to exclude Abdominal Aortic Aneurysms

Outcome Measures

Primary Outcome Measures

  1. Post-implant infrarenal aneurysm's neck grow evaluation [30 days]

    The neck diameter will be measured on Computed Tomography Angiography (CTA) at 0mm (lowest renal artery), 5mm, 10mm, 15mm and 20mm. No type I or III endoleak. No clinically significant migration (>5mm). No Aneurysm enlargement (>5mm)

  2. Post-implant infrarenal aneurysm's neck grow evaluation [6 months]

    The neck diameter will be measured on Computed Tomography Angiography (CTA) at 0mm (lowest renal artery), 5mm, 10mm, 15mm and 20mm. No type I or III endoleak. No clinically significant migration (>5mm). No Aneurysm enlargement (>5mm)

  3. Post-implant infrarenal aneurysm's neck grow evaluation [1 year]

    The neck diameter will be measured on Computed Tomography Angiography (CTA) at 0mm (lowest renal artery), 5mm, 10mm, 15mm and 20mm. No type I or III endoleak. No clinically significant migration (>5mm). No Aneurysm enlargement (>5mm)

  4. Post-implant infrarenal aneurysm's neck grow evaluation [2 years]

    The neck diameter will be measured on Computed Tomography Angiography (CTA) at 0mm (lowest renal artery), 5mm, 10mm, 15mm and 20mm. No type I or III endoleak. No clinically significant migration (>5mm). No Aneurysm enlargement (>5mm)

  5. Post-implant infrarenal aneurysm's neck grow evaluation [3 years]

    The neck diameter will be measured on Computed Tomography Angiography (CTA) at 0mm (lowest renal artery), 5mm, 10mm, 15mm and 20mm. No type I or III endoleak. No clinically significant migration (>5mm). No Aneurysm enlargement (>5mm)

Secondary Outcome Measures

  1. Procedural technical success [Immediately after the procedure]

    Immediate procedural technical success

  2. Aneurysm evaluation [3 years]

    No Aneurysm rupture

  3. Related mortality [3 years]

    AAA-related mortality

  4. Secondary Evaluations [3 years]

    Conversion to open surgical

  5. Polymer leak [3 years]

    No polymer leak during and after implant

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. Male or female at least 18 years old.

  2. Subject has signed informed consent for data release.

  3. Subjects with de novo infrarenal AAA /aorto-iliac AAA and eligible for endovascular Abdominal Aortic Aneurysm Repair with the Ovation Alto Endograft according to current IFU.

Exclusion Criteria:
  1. Currently participating in another study where primary endpoint has not been reached yet.

  2. Currently participating in another study with the same devices and/or the same primary endpoint.

  3. Known allergy to any of the device components.

  4. Pregnant (females of childbearing potential only).

Contacts and Locations

Locations

Site City State Country Postal Code
1 Hospital Universitario De Girona Dr. Josep Trueta Girona Barcelona Spain 17007
2 Hospital Universitario De Cruces Baracaldo Bizkaia Spain 48903
3 Hospital General Universitario De Toledo Toledo Castilla La Mancha Spain 45007
4 Hospital Universitario De Burgos Burgos Castilla Y Leon Spain 09006
5 Hospital Universitario de Salamanca Salamanca Castilla Y León Spain 37007
6 Hospital Universitari Son Espases Palma de Mallorca Islas Baleares Spain 07120
7 Hospital Universitario De Cabueñes Gijon Principado De Asturias Spain 33394
8 Hospital De La Santa Creu I Sant Pau Barcelona Spain 08025
9 Hospital Universitario Germans Trias i Pujol Barcelona Spain 08916

Sponsors and Collaborators

  • DGM Vascular
  • Hospital Universitario Central de Asturias

Investigators

  • Principal Investigator: Manuel Alonso Pérez, MD, Hospital Universitario Central de Asturias

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
DGM Vascular
ClinicalTrials.gov Identifier:
NCT05823519
Other Study ID Numbers:
  • NEOVAS
First Posted:
Apr 21, 2023
Last Update Posted:
Apr 21, 2023
Last Verified:
Mar 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
Yes
Keywords provided by DGM Vascular
Additional relevant MeSH terms:

Study Results

No Results Posted as of Apr 21, 2023