PULSE: Evaluation of NeoNavia® Biopsy System in Axillary Lymph Nodes

Sponsor
NeoDynamics AB (Industry)
Overall Status
Active, not recruiting
CT.gov ID
NCT03975855
Collaborator
(none)
140
7
28.5
20
0.7

Study Details

Study Description

Brief Summary

The aim of the study is to document performance characteristics of a biopsy device indicated for use in axillary lymph nodes, to provide basic insights into the complexity of axillary biopsy procedures and generate hypothesis for further larger comparative trials.

This is a Sponsor-initiated prospective, multicenter, registry trial. Patients that present with suspicious axillary lymph nodes at the time of breast cancer diagnosis undergo axillary sampling using the NeoNavia biopsy system. This is in accordance with clinical routine and current clinical guidelines. The system incorporates a new mechanism for controllable and precise needle insertion and a newly developed sampling needle for high yield sampling acquisition. It is approved for use in the breast and axillary lymph nodes.

Condition or Disease Intervention/Treatment Phase
  • Device: NeoNavia® Biopsy System

Detailed Description

Determining axillary nodal status at the time of diagnosis is paramount for optimal staging and treatment planning. SLNB is indicated for patients with a clinical and radiological negative axilla. 25%-43% of breast cancer patients are reported to present with radiologically suspicious axillary lymph nodes at the time of diagnosis. In these patients, a pre-operative ultrasound-guided needle sampling of suspicious axillary lymph tissue is indicated.

This can rationalize patient care by identifying those with axillary metastases using merely a minimally-invasive intervention. These patients can be counselled with regards to proceeding directly to definitive axillary surgery in the form of axillary lymph node dissection (ALND) rather than sentinel node biopsy (SLNB), thereby omitting a potentially unnecessary surgical procedure. Patients with a negative axillary status can proceed to SLNB for definitive nodal status determination. Furthermore, in the paradigm of neoadjuvant treatment, confirming a histopathologic involvement of lymph nodes by US-guided needle biopsies enables for decision on neoadjuvant chemotherapy without the need for a surgical procedure.

The main challenge in performing CNB (Core Needle Biopsy) within the axilla is to avoid damaging the major vessels and nerves. Technical, operator and procedural requirements that mitigate risks in CNB sampling of the axilla have been reported in the literature. It is suggested that the operator shall fully acknowledge the detailed anatomy including vessels and nerves in the axilla, have good hand-eye coordination as well as be experienced in US-guided interventions. Proper positioning of the patient is reported to be important. Color Doppler ultrasound shall be used to assess the location of large vessels relative to the intended biopsy track and to avoid sampling a vascular component of the node. Perfect guiding and visualization of the needle tip at all times is reported to be essential. It is suggested that a biopsy device with a controllable needle action is safer to use. Omitting the firing action gives the operator greater control over the final needle tip placement.

Due to the difficulty of the procedure there may be inclusion bias in the reported studies. In one series, patients presenting with nodes adjacent to a vessel or located very deep and difficult to access were not asked to participate in the study and hence not subjected to CNB. In another study FNA (Fine Needle Aspiration) was performed instead of CNB when the lymph nodes were in close proximity to vessels. A recent German survey showed that merely 79% of breast centers (41/52) perform biopsies in the axilla (data on file), and anecdotal evidence suggests that in certain departments only the most experienced physician performs CNB procedures in axillary lymph nodes, risking economic/operational inefficiencies.

For the purpose of documenting the prevalence and composition of cases deemed challenging in this study, an experienced expert panel has compiled a comprehensive list of risk parameters characterizing the anatomic complexity and procedural difficulty of axillary lymph node needle biopsies.

Recently a new biopsy device indicated for the use in breast and axillary lymph nodes (NeoNavia biopsy system, NeoDynamics, Sweden) has become available. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. Furthermore a new method of tissue acquisition is employed that has pre-clinically shown a higher sampling yield compared to CNB. These characteristics indicate that the device could be well suited for tackling even the most challenging cases of axillary lymph node biopsies. Initial clinical results indicate that in axillary lesions deemed "technically difficult", i.e. where prior US-guided biopsies with CNB or FNA had yielded non-diagnostic histology results, the NeoNavia device performed successfully thereby significantly altering clinical management.

Study Design

Study Type:
Observational
Actual Enrollment :
140 participants
Observational Model:
Case-Only
Time Perspective:
Prospective
Official Title:
Percutaneous Ultrasound-Guided Biopsy Evaluated for Axillary Lymph Node Sampling Efficacy (PULSE)
Actual Study Start Date :
Feb 14, 2019
Anticipated Primary Completion Date :
Jun 30, 2021
Anticipated Study Completion Date :
Jun 30, 2021

Arms and Interventions

Arm Intervention/Treatment
Suspicious axillary lymph nodes

All patients with histologically confirmed breast cancer or highly suspicious breast lesions presenting with suspicious axillary lymph nodes

Device: NeoNavia® Biopsy System
Biopsy of axillary lymph node using the NeoNavia Biopsy System. The investigator shall obtain as many/large samples as judged adequate and sufficient for diagnosis.

Outcome Measures

Primary Outcome Measures

  1. Rate of successful biopsies (= success rates) [after histopathological analysis af tissue samples, up to 1 week after biopsy]

    Lymph node tissue present in biopsy samples as assessed by histopathologist

Secondary Outcome Measures

  1. Rate of patients presenting with risk parameters for an anatomically complex procedure [time of biopsy, 1 day]

    Based on a list of parameters established by an expert panel to characterize the anatomic complexity of axillary biopsy procedures

  2. Rate of cases in which it was possible to target the selected lymph node or, if present, the lesion inside the node [time of biopsy, 1 day]

  3. Rate of cases in which pulses facilitated control during needle insertion [time of biopsy, 1 day]

  4. Sensitivity [post-surgery, up to 200 days]

  5. Specificity [post-surgery, up to 200 days]

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • cT1-4c (multifocality / multicentricity permitted)

  • Female / male patient aged ≥ 18 years

  • cN+ based on the following criteria (at least one criteria must be met):

  • lymph node is palpable

  • cortical asymmetry (focal or diffuse cortical thickening of >3mm) under US

  • cortex:hilum ratio >2:1 under US

  • loss of hilum/cortex structure under US

  • Written informed consent (ICF)

Exclusion Criteria:
  • Suspicious lymph nodes after neoadjuvant therapy

  • No confirmed breast cancer and no abnormality in the breast

  • Patient uses Marcumar

  • Pregnant and lactating women

  • Known hypersensitivity reaction against local anesthesia

  • Prior chemo or radiation therapy in breast or axilla

  • Missing written informed consent

Contacts and Locations

Locations

Site City State Country Postal Code
1 Klinikum Esslingen Esslingen BW Germany 73730
2 Universitätsfrauenklinik Tübingen Tübingen BW Germany 72076
3 Agaplesion Markus Krankenhaus Frankfurt HE Germany 60431
4 Universitäts-Frauenklinik Rostock MV Germany 18059
5 HJK Erkelenz Erkelenz NRW Germany 41812
6 Kliniken Essen-Mitte Essen NRW Germany 45136
7 Uniklinik Köln Köln NRW Germany 50226

Sponsors and Collaborators

  • NeoDynamics AB

Investigators

  • Principal Investigator: Marc Thill, PD Dr., Leading Principal Investigator

Study Documents (Full-Text)

None provided.

More Information

Additional Information:

Publications

Responsible Party:
NeoDynamics AB
ClinicalTrials.gov Identifier:
NCT03975855
Other Study ID Numbers:
  • NEODOC-2021668610-165
First Posted:
Jun 5, 2019
Last Update Posted:
Mar 5, 2021
Last Verified:
Mar 1, 2021
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by NeoDynamics AB
Additional relevant MeSH terms:

Study Results

No Results Posted as of Mar 5, 2021